Study on the heating law of thermal effect of HIFU on tissue based on piezoelectric ceramic voltage and vibration frequency
Abstract When high-intensity focused ultrasound (HIFU) is used to heat human tissues during surgery, shortening the heating time and increasing the heating rate are crucial for implementing surgery. During operations, the vibration frequencies and voltages that are suitable for piezoelectric ceramic...
Saved in:
| Main Authors: | Yuping Long, Yi Gan, Fujia Sun, Yansong Zhao |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Nature Portfolio
2025-02-01
|
| Series: | Scientific Reports |
| Subjects: | |
| Online Access: | https://doi.org/10.1038/s41598-025-87166-6 |
| Tags: |
Add Tag