An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm
In order to efficiently and effectively reconstruct 3D medical images and clearly display the detailed information of inner structures and the inner hidden interfaces between different media, an Improved Volume Rendering Optical Model (IVROM) for medical translucent volume rendering and its implemen...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2010-01-01
|
Series: | International Journal of Biomedical Imaging |
Online Access: | http://dx.doi.org/10.1155/2010/429051 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832567585699266560 |
---|---|
author | Bin Li Lianfang Tian Shanxing Ou |
author_facet | Bin Li Lianfang Tian Shanxing Ou |
author_sort | Bin Li |
collection | DOAJ |
description | In order to efficiently and effectively reconstruct 3D medical images and clearly display the detailed information of inner structures and the inner hidden interfaces between different media, an Improved Volume Rendering Optical Model (IVROM) for medical translucent volume rendering and its implementation using the preintegrated Shear-Warp Volume Rendering algorithm are proposed in this paper, which can be readily applied on a commodity PC. Based on the classical absorption and emission model, effects of volumetric shadows and direct and indirect scattering are also considered in the proposed model IVROM. Moreover, the implementation of the Improved Translucent Volume Rendering Method (ITVRM) integrating the IVROM model, Shear-Warp and preintegrated volume rendering algorithm is described, in which the aliasing and staircase effects resulting from under-sampling in Shear-Warp, are avoided by the preintegrated volume rendering technique. This study demonstrates the superiority of the proposed method. |
format | Article |
id | doaj-art-4fa82ceea301414483938e0b1df6e09c |
institution | Kabale University |
issn | 1687-4188 1687-4196 |
language | English |
publishDate | 2010-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Biomedical Imaging |
spelling | doaj-art-4fa82ceea301414483938e0b1df6e09c2025-02-03T01:01:07ZengWileyInternational Journal of Biomedical Imaging1687-41881687-41962010-01-01201010.1155/2010/429051429051An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp AlgorithmBin Li0Lianfang Tian1Shanxing Ou2School of Automation Science and Engineering, South China University of Technology, Guangzhou, Guangdong 510640, ChinaSchool of Automation Science and Engineering, South China University of Technology, Guangzhou, Guangdong 510640, ChinaDepartment of Radiology, Guangzhou General Hospital of Guangzhou Command, Guangzhou, Guangdong 510010, ChinaIn order to efficiently and effectively reconstruct 3D medical images and clearly display the detailed information of inner structures and the inner hidden interfaces between different media, an Improved Volume Rendering Optical Model (IVROM) for medical translucent volume rendering and its implementation using the preintegrated Shear-Warp Volume Rendering algorithm are proposed in this paper, which can be readily applied on a commodity PC. Based on the classical absorption and emission model, effects of volumetric shadows and direct and indirect scattering are also considered in the proposed model IVROM. Moreover, the implementation of the Improved Translucent Volume Rendering Method (ITVRM) integrating the IVROM model, Shear-Warp and preintegrated volume rendering algorithm is described, in which the aliasing and staircase effects resulting from under-sampling in Shear-Warp, are avoided by the preintegrated volume rendering technique. This study demonstrates the superiority of the proposed method.http://dx.doi.org/10.1155/2010/429051 |
spellingShingle | Bin Li Lianfang Tian Shanxing Ou An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm International Journal of Biomedical Imaging |
title | An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm |
title_full | An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm |
title_fullStr | An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm |
title_full_unstemmed | An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm |
title_short | An Optical Model for Translucent Volume Rendering and Its Implementation Using the Preintegrated Shear-Warp Algorithm |
title_sort | optical model for translucent volume rendering and its implementation using the preintegrated shear warp algorithm |
url | http://dx.doi.org/10.1155/2010/429051 |
work_keys_str_mv | AT binli anopticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm AT lianfangtian anopticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm AT shanxingou anopticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm AT binli opticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm AT lianfangtian opticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm AT shanxingou opticalmodelfortranslucentvolumerenderinganditsimplementationusingthepreintegratedshearwarpalgorithm |