Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper

A new type of limit response amplifying device (cam-type response amplifying device) was proposed in order to be able to solve the shortcomings of the seismic performance of the prefabricated concrete structures and the shortcomings of the existing response amplification devices that were prone to f...

Full description

Saved in:
Bibliographic Details
Main Authors: Luyao Wei, Huijiao Nie
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2022/3386719
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832561833870884864
author Luyao Wei
Huijiao Nie
author_facet Luyao Wei
Huijiao Nie
author_sort Luyao Wei
collection DOAJ
description A new type of limit response amplifying device (cam-type response amplifying device) was proposed in order to be able to solve the shortcomings of the seismic performance of the prefabricated concrete structures and the shortcomings of the existing response amplification devices that were prone to failure under rare earthquakes. On the basis of the unit library provided by ABAQUS, the secondary development was carried out and the dynamic time history analysis was performed on the solid model of the prefabricated frame structure. We selected the displacement angle between layers as the structural damage index and used the dynamic incremental method to analyze the seismic vulnerability of the uncontrolled structure without the cam-type response amplification device and the added damping structure. The results show that compared with the uncontrolled structure, the damping structure with a cam-type response amplification device had a significant reduction in the probability of reaching various failure states, and the seismic performance was effectively improved. The cam-type response amplifier had an excellent shock absorption effect under the action of all levels of the earthquake, which could effectively reduce the damage degree to the structure. Through the analysis of the vulnerability curve, it could provide the basis for the design method based on the behavior of the prefabricated concrete structures.
format Article
id doaj-art-4ce8562e4c2e4094bc4160d7047cf70e
institution Kabale University
issn 1687-8094
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-4ce8562e4c2e4094bc4160d7047cf70e2025-02-03T01:24:08ZengWileyAdvances in Civil Engineering1687-80942022-01-01202210.1155/2022/3386719Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous DamperLuyao Wei0Huijiao Nie1Department of Architectural EngineeringDepartment of Architectural EngineeringA new type of limit response amplifying device (cam-type response amplifying device) was proposed in order to be able to solve the shortcomings of the seismic performance of the prefabricated concrete structures and the shortcomings of the existing response amplification devices that were prone to failure under rare earthquakes. On the basis of the unit library provided by ABAQUS, the secondary development was carried out and the dynamic time history analysis was performed on the solid model of the prefabricated frame structure. We selected the displacement angle between layers as the structural damage index and used the dynamic incremental method to analyze the seismic vulnerability of the uncontrolled structure without the cam-type response amplification device and the added damping structure. The results show that compared with the uncontrolled structure, the damping structure with a cam-type response amplification device had a significant reduction in the probability of reaching various failure states, and the seismic performance was effectively improved. The cam-type response amplifier had an excellent shock absorption effect under the action of all levels of the earthquake, which could effectively reduce the damage degree to the structure. Through the analysis of the vulnerability curve, it could provide the basis for the design method based on the behavior of the prefabricated concrete structures.http://dx.doi.org/10.1155/2022/3386719
spellingShingle Luyao Wei
Huijiao Nie
Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
Advances in Civil Engineering
title Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
title_full Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
title_fullStr Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
title_full_unstemmed Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
title_short Seismic Vulnerability Analysis of Prefabricated Concrete Frame with a Cam-Type Response Amplifying Device of Viscous Damper
title_sort seismic vulnerability analysis of prefabricated concrete frame with a cam type response amplifying device of viscous damper
url http://dx.doi.org/10.1155/2022/3386719
work_keys_str_mv AT luyaowei seismicvulnerabilityanalysisofprefabricatedconcreteframewithacamtyperesponseamplifyingdeviceofviscousdamper
AT huijiaonie seismicvulnerabilityanalysisofprefabricatedconcreteframewithacamtyperesponseamplifyingdeviceofviscousdamper