Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations
The extensive use and misuse of selective serotonin reuptake inhibitors (SSRIs) in drug formulations has resulted in their accumulation in food sources and environment, posing noteworthy threats to human health and the global economy. Dapoxetine hydrochloride (DPH) is one of the recent oral drugs fr...
Saved in:
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-04-01
|
Series: | Electrochemistry Communications |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1388248125000141 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832087711962365952 |
---|---|
author | H. Alwael N.A. Asiri B.G. Alhogbi A.S. Alharthi E.A. Bahaidarah T.N. Abduljabbar D.F. Baamer M. Madkour F.A. Zainy M.S. El-Shahawi |
author_facet | H. Alwael N.A. Asiri B.G. Alhogbi A.S. Alharthi E.A. Bahaidarah T.N. Abduljabbar D.F. Baamer M. Madkour F.A. Zainy M.S. El-Shahawi |
author_sort | H. Alwael |
collection | DOAJ |
description | The extensive use and misuse of selective serotonin reuptake inhibitors (SSRIs) in drug formulations has resulted in their accumulation in food sources and environment, posing noteworthy threats to human health and the global economy. Dapoxetine hydrochloride (DPH) is one of the recent oral drugs frequently misused for the treatment of male sexual dysfunction of premature ejaculation and has lately international attention. Hence, the current study reports a simple and low cost electrochemical probe based on glassy carbon electrode (GCE) combining adsorptive square wave - anodic stripping voltammeter (Ads SW-ASV) for detection of DPH in aqueous solution at pH 3. The proposed probe displayed limits of detection (LOD) and quantification (LOQ) of 5.0 × 10−7 and 1.56 × 10−6 M, respectively, with a wide linear dynamic range (LDR) of 1.0 × 10−6–1.0 × 10−4 M of DPH. The sensor also revealed remarkable reproducibility, stability, and resistance towards interference. The probe also has favorable LOD and good LDR compared to the recent reported assays for DPH detection. The probe was applied for detection of DPH in its drug formulations and its residues in water samples with acceptable recoveries (98.5 ± 0.014–104 ± 0.016 %) with favorable repeatability and reproducibility. The experimental Student texp test (n = 5) was lower than tabulated t value t (2.78) at 95 % confidence (n = 5) demonstrating the reliability of the probe towards DPH detection in water and signifying the potential practices for DPH detection in complex matrices. Thus, the probe revealed good performance making it a talented candidate for practical detection of DPH. Interference of some frequently found components in drug residues in water and long-term stability of the probe was also assigned. The probe is simple, robust, and able to detect DPH in complex matrix with high recoveries. |
format | Article |
id | doaj-art-45f5ca1cc86b45d4b47bca67dfab5e9f |
institution | Kabale University |
issn | 1388-2481 |
language | English |
publishDate | 2025-04-01 |
publisher | Elsevier |
record_format | Article |
series | Electrochemistry Communications |
spelling | doaj-art-45f5ca1cc86b45d4b47bca67dfab5e9f2025-02-06T05:11:13ZengElsevierElectrochemistry Communications1388-24812025-04-01173107875Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulationsH. Alwael0N.A. Asiri1B.G. Alhogbi2A.S. Alharthi3E.A. Bahaidarah4T.N. Abduljabbar5D.F. Baamer6M. Madkour7F.A. Zainy8M.S. El-Shahawi9Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia; Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia; Department of Chemistry, Faculty of Applied Sciences, Umm AL-Qura University, Makkah, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi ArabiaDepartment of Environment, Faculty of Environmental Sciences, King Abdulaziz University, Jeddah, Saudi ArabiaDepartment of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi ArabiaDepartment of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia; Department of Chemistry, Faculty of Science, Damietta University, New Damietta, Damietta, Egypt; Corresponding author at: Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.The extensive use and misuse of selective serotonin reuptake inhibitors (SSRIs) in drug formulations has resulted in their accumulation in food sources and environment, posing noteworthy threats to human health and the global economy. Dapoxetine hydrochloride (DPH) is one of the recent oral drugs frequently misused for the treatment of male sexual dysfunction of premature ejaculation and has lately international attention. Hence, the current study reports a simple and low cost electrochemical probe based on glassy carbon electrode (GCE) combining adsorptive square wave - anodic stripping voltammeter (Ads SW-ASV) for detection of DPH in aqueous solution at pH 3. The proposed probe displayed limits of detection (LOD) and quantification (LOQ) of 5.0 × 10−7 and 1.56 × 10−6 M, respectively, with a wide linear dynamic range (LDR) of 1.0 × 10−6–1.0 × 10−4 M of DPH. The sensor also revealed remarkable reproducibility, stability, and resistance towards interference. The probe also has favorable LOD and good LDR compared to the recent reported assays for DPH detection. The probe was applied for detection of DPH in its drug formulations and its residues in water samples with acceptable recoveries (98.5 ± 0.014–104 ± 0.016 %) with favorable repeatability and reproducibility. The experimental Student texp test (n = 5) was lower than tabulated t value t (2.78) at 95 % confidence (n = 5) demonstrating the reliability of the probe towards DPH detection in water and signifying the potential practices for DPH detection in complex matrices. Thus, the probe revealed good performance making it a talented candidate for practical detection of DPH. Interference of some frequently found components in drug residues in water and long-term stability of the probe was also assigned. The probe is simple, robust, and able to detect DPH in complex matrix with high recoveries.http://www.sciencedirect.com/science/article/pii/S1388248125000141Dapoxetine hydrochloride formulationsDrug residuesStripping voltammetryEnvironmental water samples |
spellingShingle | H. Alwael N.A. Asiri B.G. Alhogbi A.S. Alharthi E.A. Bahaidarah T.N. Abduljabbar D.F. Baamer M. Madkour F.A. Zainy M.S. El-Shahawi Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations Electrochemistry Communications Dapoxetine hydrochloride formulations Drug residues Stripping voltammetry Environmental water samples |
title | Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations |
title_full | Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations |
title_fullStr | Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations |
title_full_unstemmed | Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations |
title_short | Probe – Integrated electrochemical sensing platform for detection of trace levels of Dapoxetine hydrochloride drug residue in water and drug formulations |
title_sort | probe integrated electrochemical sensing platform for detection of trace levels of dapoxetine hydrochloride drug residue in water and drug formulations |
topic | Dapoxetine hydrochloride formulations Drug residues Stripping voltammetry Environmental water samples |
url | http://www.sciencedirect.com/science/article/pii/S1388248125000141 |
work_keys_str_mv | AT halwael probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT naasiri probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT bgalhogbi probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT asalharthi probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT eabahaidarah probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT tnabduljabbar probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT dfbaamer probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT mmadkour probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT fazainy probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations AT mselshahawi probeintegratedelectrochemicalsensingplatformfordetectionoftracelevelsofdapoxetinehydrochloridedrugresidueinwateranddrugformulations |