Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator

Pulses of near-fault earthquakes are very effective in the seismic response of the Triple Friction Pendulum Isolator (TFPI). In previous studies, the effect of original bi-directional pulses components on the isolated tall buildings by TFPI was neglected. Also, the effect of changing the design para...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali Majdi, Mohammadreza Mashayekhi, Ataallah Sadeghi-Movahhed
Format: Article
Language:English
Published: Semnan University 2024-02-01
Series:Journal of Rehabilitation in Civil Engineering
Subjects:
Online Access:https://civiljournal.semnan.ac.ir/article_7931_0b176937ba2506fb4b01b73448d7c1ff.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832591989536718848
author Ali Majdi
Mohammadreza Mashayekhi
Ataallah Sadeghi-Movahhed
author_facet Ali Majdi
Mohammadreza Mashayekhi
Ataallah Sadeghi-Movahhed
author_sort Ali Majdi
collection DOAJ
description Pulses of near-fault earthquakes are very effective in the seismic response of the Triple Friction Pendulum Isolator (TFPI). In previous studies, the effect of original bi-directional pulses components on the isolated tall buildings by TFPI was neglected. Also, the effect of changing the design parameters of TFPI on preventing seismic disaster in this type of building is unknown. For this reason, a 10 stories moment steel structure mounted on TFPI was designed. Then, the seven pairs of bidirectional near-fault earthquake records without and with removal pulses were applied to the isolated structure. The results show that the seismic responses on the base level decrease by reducing the velocity pulse amplitude (AP) and increasing the velocity pulse period (TP), also if the period of the isolators (TM) is being higher than TP, the seismic responses on the upper floors reduce. Moreover, Increasing the geometrical dimensions of the TFPI can significantly reduce the seismic effect of near-fault earthquake with pulses.
format Article
id doaj-art-45b428caa97744ab8cd31b15b754e16e
institution Kabale University
issn 2345-4415
2345-4423
language English
publishDate 2024-02-01
publisher Semnan University
record_format Article
series Journal of Rehabilitation in Civil Engineering
spelling doaj-art-45b428caa97744ab8cd31b15b754e16e2025-01-21T20:47:24ZengSemnan UniversityJournal of Rehabilitation in Civil Engineering2345-44152345-44232024-02-01121476210.22075/jrce.2023.30434.18457931Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum IsolatorAli Majdi0Mohammadreza Mashayekhi1Ataallah Sadeghi-Movahhed2Department of Building and Construction Techniques Engineering, Al- Mustaqbal University College, 51001 Hilla, IraqAssistant Professor, Department of Civil Engineering, K. N. Toosi University of Technology, Tehran, IranDepartment of Civil Engineering, Shabestar Branch, Islamic Azad University, Shabestar, IranPulses of near-fault earthquakes are very effective in the seismic response of the Triple Friction Pendulum Isolator (TFPI). In previous studies, the effect of original bi-directional pulses components on the isolated tall buildings by TFPI was neglected. Also, the effect of changing the design parameters of TFPI on preventing seismic disaster in this type of building is unknown. For this reason, a 10 stories moment steel structure mounted on TFPI was designed. Then, the seven pairs of bidirectional near-fault earthquake records without and with removal pulses were applied to the isolated structure. The results show that the seismic responses on the base level decrease by reducing the velocity pulse amplitude (AP) and increasing the velocity pulse period (TP), also if the period of the isolators (TM) is being higher than TP, the seismic responses on the upper floors reduce. Moreover, Increasing the geometrical dimensions of the TFPI can significantly reduce the seismic effect of near-fault earthquake with pulses.https://civiljournal.semnan.ac.ir/article_7931_0b176937ba2506fb4b01b73448d7c1ff.pdfmid-rise buildingtriple friction pendulum isolatornear-fault earthquakespulse characteristic
spellingShingle Ali Majdi
Mohammadreza Mashayekhi
Ataallah Sadeghi-Movahhed
Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
Journal of Rehabilitation in Civil Engineering
mid-rise building
triple friction pendulum isolator
near-fault earthquakes
pulse characteristic
title Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
title_full Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
title_fullStr Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
title_full_unstemmed Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
title_short Effect of Near-Fault Earthquake Characteristics on Seismic Response of Mid-Rise Structures with Triple Friction Pendulum Isolator
title_sort effect of near fault earthquake characteristics on seismic response of mid rise structures with triple friction pendulum isolator
topic mid-rise building
triple friction pendulum isolator
near-fault earthquakes
pulse characteristic
url https://civiljournal.semnan.ac.ir/article_7931_0b176937ba2506fb4b01b73448d7c1ff.pdf
work_keys_str_mv AT alimajdi effectofnearfaultearthquakecharacteristicsonseismicresponseofmidrisestructureswithtriplefrictionpendulumisolator
AT mohammadrezamashayekhi effectofnearfaultearthquakecharacteristicsonseismicresponseofmidrisestructureswithtriplefrictionpendulumisolator
AT ataallahsadeghimovahhed effectofnearfaultearthquakecharacteristicsonseismicresponseofmidrisestructureswithtriplefrictionpendulumisolator