Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion

The infusion bag is mainly made up of polyolefin polymer. Antioxidants are usually added to these polymer materials in the production process to prevent the materials from aging and enhance the stability of the materials. Because of the potential harm of antioxidants to human body, it is necessary t...

Full description

Saved in:
Bibliographic Details
Main Authors: Bo Tao, Gang Wang, Zongning Yin, Xiaocong Pu, Yan Jiang, Luohong Zhang, Jie Cheng, Yong Li, Jiayu Zhang
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2020/8869576
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832546866996183040
author Bo Tao
Gang Wang
Zongning Yin
Xiaocong Pu
Yan Jiang
Luohong Zhang
Jie Cheng
Yong Li
Jiayu Zhang
author_facet Bo Tao
Gang Wang
Zongning Yin
Xiaocong Pu
Yan Jiang
Luohong Zhang
Jie Cheng
Yong Li
Jiayu Zhang
author_sort Bo Tao
collection DOAJ
description The infusion bag is mainly made up of polyolefin polymer. Antioxidants are usually added to these polymer materials in the production process to prevent the materials from aging and enhance the stability of the materials. Because of the potential harm of antioxidants to human body, it is necessary to limit the amount of antioxidants migrating to the pharmaceutical solutions. In the present study, we developed and validated the HPLC method for the simultaneous quantification of antioxidants and their degradation products migrating to sodium chloride solution for injection. A total of six antioxidants and six their degradation products were separated and simultaneously determined by using a Waters Symmetry RP18 column (250 × 4.6 mm, 5 μm) and gradient elution of methanol/acetonitrile/acetic acid-water (1 : 99, v/v) at a flow rate of 1.0 mL/min. The detective wavelength was set at 277 nm, and the column temperature was maintained at 35°C. The method was validated in terms of limit of detection (LOD, 0.011–0.151 μg/mL), limit of quantification (LOQ, 0.031–0.393 μg/mL), intraday precision (0.25%–3.17%), interday precision (0.47%–3.48%), linearity (0.1–46.8 μg/mL, r > 0.9994), stability (0.35%–3.29%), and accuracy (80.39%–104.31%). In the extraction experiment, antioxidants, BHT, 1010, 1330, 1076, and 168, and their degradation products, 1310 and DBP, were detected in the packaging materials. Only 1310 was detected in the migration experiment. The maximum daily dosage of sodium chloride for blood transfusion is three bags, and the content of 1310 in long-term testing samples is from 0 to 12 months ranging from 37.44 μg/3 bags to 48.71 μg/3 bags. The daily intake of 1310 did not exceed 48.71 μg, which was much lower than its permitted daily exposure (PDE, 300 μg/day). Therefore, the antioxidants and their degradation products migrating into the drug solution would not cause drug safety risks.
format Article
id doaj-art-42408e5ef5fd45e8b91acdd3dcadb1b2
institution Kabale University
issn 2090-8865
2090-8873
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-42408e5ef5fd45e8b91acdd3dcadb1b22025-02-03T06:46:41ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732020-01-01202010.1155/2020/88695768869576Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood TransfusionBo Tao0Gang Wang1Zongning Yin2Xiaocong Pu3Yan Jiang4Luohong Zhang5Jie Cheng6Yong Li7Jiayu Zhang8Key Laboratory of Drug Targeting and Drug Delivery Systems, West China School of Pharmacy, Sichuan University, No. 17, Block 3, Southern Renmin Road, Chengdu 610041, ChinaSichuan Institute for Food and Drug Control, Chengdu 611731, ChinaKey Laboratory of Drug Targeting and Drug Delivery Systems, West China School of Pharmacy, Sichuan University, No. 17, Block 3, Southern Renmin Road, Chengdu 610041, ChinaSichuan Institute for Food and Drug Control, Chengdu 611731, ChinaSichuan Institute for Food and Drug Control, Chengdu 611731, ChinaSichuan Institute for Food and Drug Control, Chengdu 611731, ChinaSichuan Institute for Food and Drug Control, Chengdu 611731, ChinaSichuan Taipingyang Pharmaceutical Co., Ltd., Chengdu 611731, ChinaSichuan Taipingyang Pharmaceutical Co., Ltd., Chengdu 611731, ChinaThe infusion bag is mainly made up of polyolefin polymer. Antioxidants are usually added to these polymer materials in the production process to prevent the materials from aging and enhance the stability of the materials. Because of the potential harm of antioxidants to human body, it is necessary to limit the amount of antioxidants migrating to the pharmaceutical solutions. In the present study, we developed and validated the HPLC method for the simultaneous quantification of antioxidants and their degradation products migrating to sodium chloride solution for injection. A total of six antioxidants and six their degradation products were separated and simultaneously determined by using a Waters Symmetry RP18 column (250 × 4.6 mm, 5 μm) and gradient elution of methanol/acetonitrile/acetic acid-water (1 : 99, v/v) at a flow rate of 1.0 mL/min. The detective wavelength was set at 277 nm, and the column temperature was maintained at 35°C. The method was validated in terms of limit of detection (LOD, 0.011–0.151 μg/mL), limit of quantification (LOQ, 0.031–0.393 μg/mL), intraday precision (0.25%–3.17%), interday precision (0.47%–3.48%), linearity (0.1–46.8 μg/mL, r > 0.9994), stability (0.35%–3.29%), and accuracy (80.39%–104.31%). In the extraction experiment, antioxidants, BHT, 1010, 1330, 1076, and 168, and their degradation products, 1310 and DBP, were detected in the packaging materials. Only 1310 was detected in the migration experiment. The maximum daily dosage of sodium chloride for blood transfusion is three bags, and the content of 1310 in long-term testing samples is from 0 to 12 months ranging from 37.44 μg/3 bags to 48.71 μg/3 bags. The daily intake of 1310 did not exceed 48.71 μg, which was much lower than its permitted daily exposure (PDE, 300 μg/day). Therefore, the antioxidants and their degradation products migrating into the drug solution would not cause drug safety risks.http://dx.doi.org/10.1155/2020/8869576
spellingShingle Bo Tao
Gang Wang
Zongning Yin
Xiaocong Pu
Yan Jiang
Luohong Zhang
Jie Cheng
Yong Li
Jiayu Zhang
Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
Journal of Analytical Methods in Chemistry
title Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
title_full Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
title_fullStr Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
title_full_unstemmed Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
title_short Determination of the Contents of Antioxidants and Their Degradation Products in Sodium Chloride Injection for Blood Transfusion
title_sort determination of the contents of antioxidants and their degradation products in sodium chloride injection for blood transfusion
url http://dx.doi.org/10.1155/2020/8869576
work_keys_str_mv AT botao determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT gangwang determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT zongningyin determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT xiaocongpu determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT yanjiang determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT luohongzhang determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT jiecheng determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT yongli determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion
AT jiayuzhang determinationofthecontentsofantioxidantsandtheirdegradationproductsinsodiumchlorideinjectionforbloodtransfusion