Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus

Background. The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. Methods. 29 patients aged 15 years or younger w...

Full description

Saved in:
Bibliographic Details
Main Authors: Mika Ichimura, Satoshi Ueki, Takeo Fukuchi
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2024/2173860
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832553184081477632
author Mika Ichimura
Satoshi Ueki
Takeo Fukuchi
author_facet Mika Ichimura
Satoshi Ueki
Takeo Fukuchi
author_sort Mika Ichimura
collection DOAJ
description Background. The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. Methods. 29 patients aged 15 years or younger who visited our hospital for refraction examinations with SVS before and at least 60 minutes after administration of 2 drops of 1% cyclopentolate ophthalmic solution (before and after cycloplegia) were included in this study. Two SVS measurements were made before and after cycloplegia, respectively. Intraclass correlation coefficients (ICCs) and Bland–Altman analysis for spherical, spherical equivalent (SE), cylindrical, J0, and J45 values before and after cycloplegia were analyzed. Results. The mean age ± standard deviation (SD) of the 29 patients was 7.6 ± 2.4 years. There were 11 males and 18 females. The mean spherical values based on the SVS before and after cycloplegia were 0.42 ± 1.67 diopter (D), and 1.47 ± 2.23 D for the first measurement and 0.60 ± 1.74 D, and 1.42 ± 2.27 D for the second measurement, respectively. The mean cylindrical values based on SVS before and after cycloplegia were −1.45 ± 0.96 D and −1.65 ± 0.89 D for the first measurement and −1.58 ± 1.13 D and −1.66 ± 0.91 D for the second measurement, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values before cycloplegia were 0.95, 0.98, 0.83, 0.86, and 0.86, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values after cycloplegia were 0.99, 0.99, 0,87, 0.73, and 0.80, respectively. The Bland–Altman analysis of the first and second spherical and SE values before cycloplegia showed fan-shaped variation as hyperopia increased. Conclusions. Two consecutive SVS refraction measurements have a high degree of reproducibility for spherical and SE values but a low degree for cylindrical, J0, and J45 values. From these results, multiple measurements are required to obtain reliable results for cylindrical values.
format Article
id doaj-art-3eb6d79b08314a7b95cc2589b02fbae3
institution Kabale University
issn 2090-0058
language English
publishDate 2024-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-3eb6d79b08314a7b95cc2589b02fbae32025-02-03T05:54:35ZengWileyJournal of Ophthalmology2090-00582024-01-01202410.1155/2024/2173860Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including StrabismusMika Ichimura0Satoshi Ueki1Takeo Fukuchi2Division of Ophthalmology and Visual ScienceDivision of Ophthalmology and Visual ScienceDivision of Ophthalmology and Visual ScienceBackground. The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. Methods. 29 patients aged 15 years or younger who visited our hospital for refraction examinations with SVS before and at least 60 minutes after administration of 2 drops of 1% cyclopentolate ophthalmic solution (before and after cycloplegia) were included in this study. Two SVS measurements were made before and after cycloplegia, respectively. Intraclass correlation coefficients (ICCs) and Bland–Altman analysis for spherical, spherical equivalent (SE), cylindrical, J0, and J45 values before and after cycloplegia were analyzed. Results. The mean age ± standard deviation (SD) of the 29 patients was 7.6 ± 2.4 years. There were 11 males and 18 females. The mean spherical values based on the SVS before and after cycloplegia were 0.42 ± 1.67 diopter (D), and 1.47 ± 2.23 D for the first measurement and 0.60 ± 1.74 D, and 1.42 ± 2.27 D for the second measurement, respectively. The mean cylindrical values based on SVS before and after cycloplegia were −1.45 ± 0.96 D and −1.65 ± 0.89 D for the first measurement and −1.58 ± 1.13 D and −1.66 ± 0.91 D for the second measurement, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values before cycloplegia were 0.95, 0.98, 0.83, 0.86, and 0.86, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values after cycloplegia were 0.99, 0.99, 0,87, 0.73, and 0.80, respectively. The Bland–Altman analysis of the first and second spherical and SE values before cycloplegia showed fan-shaped variation as hyperopia increased. Conclusions. Two consecutive SVS refraction measurements have a high degree of reproducibility for spherical and SE values but a low degree for cylindrical, J0, and J45 values. From these results, multiple measurements are required to obtain reliable results for cylindrical values.http://dx.doi.org/10.1155/2024/2173860
spellingShingle Mika Ichimura
Satoshi Ueki
Takeo Fukuchi
Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
Journal of Ophthalmology
title Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
title_full Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
title_fullStr Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
title_full_unstemmed Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
title_short Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus
title_sort test retest of the spot vision screener among children with ophthalmological diseases including strabismus
url http://dx.doi.org/10.1155/2024/2173860
work_keys_str_mv AT mikaichimura testretestofthespotvisionscreeneramongchildrenwithophthalmologicaldiseasesincludingstrabismus
AT satoshiueki testretestofthespotvisionscreeneramongchildrenwithophthalmologicaldiseasesincludingstrabismus
AT takeofukuchi testretestofthespotvisionscreeneramongchildrenwithophthalmologicaldiseasesincludingstrabismus