Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty

No matter in metal mines or coal mines, an emulsion pump station has a wide range of application market and can play an important role. In this paper, the frequency conversion constant pressure control system of the mine emulsion pump station is taken as the research object. The two kinds of water-b...

Full description

Saved in:
Bibliographic Details
Main Authors: Cong Tian, Xiwen Wei, Chao Yang, Chang Su
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2021/5569994
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832554004426522624
author Cong Tian
Xiwen Wei
Chao Yang
Chang Su
author_facet Cong Tian
Xiwen Wei
Chao Yang
Chang Su
author_sort Cong Tian
collection DOAJ
description No matter in metal mines or coal mines, an emulsion pump station has a wide range of application market and can play an important role. In this paper, the frequency conversion constant pressure control system of the mine emulsion pump station is taken as the research object. The two kinds of water-based drawing fluids used are dispersed drawing fluid and emulsion drawing fluid. After the intelligent level of the equipment reaches a very high level, an environmentally friendly, safe, and efficient Internet of Things technology system will be added. Combined with 3D laser scanning technology based on self-scanning of road contours, the blast method is input to the terminals of the emulsion pump station for automatic blast hole positioning and semiautomation of the emulsion pump station. Combined with 5 g communication and other intelligent key technologies, it realizes high-end functions such as fault self-diagnosis, remote operation, and remote monitoring of the emulsion pump station and rock drill, which can be called full intelligent stage. The results show that the initial friction coefficient of drawing fluid A lubrication is 0.21, and then, with the extension of time, the friction coefficient gradually decreases to 0.14. The initial friction coefficient of drawing fluid B is 0.22, then it decreases rapidly to 0.13, then it is stable at 0.17, and then it remains basically unchanged. When the temperature is 55°C, the initial friction coefficient is 0.16 and then decreases to 0.12. Therefore, the frequency conversion constant pressure control system of the mine emulsion pump station should be selected according to the environment and application scenarios.
format Article
id doaj-art-3e0d3f2d37ae47998bc0d5afc74a26d9
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-3e0d3f2d37ae47998bc0d5afc74a26d92025-02-03T05:52:35ZengWileyAdvances in Civil Engineering1687-80861687-80942021-01-01202110.1155/2021/55699945569994Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation SpecialtyCong Tian0Xiwen Wei1Chao Yang2Chang Su3School of Electrical and Information Engineering, Heilongjiang University of Technology, Jixi 158100, Heilongjiang, ChinaSchool of Electrical and Information Engineering, Heilongjiang University of Technology, Jixi 158100, Heilongjiang, ChinaJieyang Institute of Technology, Guangdong University of Technology, Jieyang 522000, Guangdong, ChinaJieyang Institute of Technology, Guangdong University of Technology, Jieyang 522000, Guangdong, ChinaNo matter in metal mines or coal mines, an emulsion pump station has a wide range of application market and can play an important role. In this paper, the frequency conversion constant pressure control system of the mine emulsion pump station is taken as the research object. The two kinds of water-based drawing fluids used are dispersed drawing fluid and emulsion drawing fluid. After the intelligent level of the equipment reaches a very high level, an environmentally friendly, safe, and efficient Internet of Things technology system will be added. Combined with 3D laser scanning technology based on self-scanning of road contours, the blast method is input to the terminals of the emulsion pump station for automatic blast hole positioning and semiautomation of the emulsion pump station. Combined with 5 g communication and other intelligent key technologies, it realizes high-end functions such as fault self-diagnosis, remote operation, and remote monitoring of the emulsion pump station and rock drill, which can be called full intelligent stage. The results show that the initial friction coefficient of drawing fluid A lubrication is 0.21, and then, with the extension of time, the friction coefficient gradually decreases to 0.14. The initial friction coefficient of drawing fluid B is 0.22, then it decreases rapidly to 0.13, then it is stable at 0.17, and then it remains basically unchanged. When the temperature is 55°C, the initial friction coefficient is 0.16 and then decreases to 0.12. Therefore, the frequency conversion constant pressure control system of the mine emulsion pump station should be selected according to the environment and application scenarios.http://dx.doi.org/10.1155/2021/5569994
spellingShingle Cong Tian
Xiwen Wei
Chao Yang
Chang Su
Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
Advances in Civil Engineering
title Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
title_full Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
title_fullStr Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
title_full_unstemmed Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
title_short Optimization Technology of Frequency Conversion Constant Pressure Control System of Mine Emulsion Pump Station in Electrical Engineering and Automation Specialty
title_sort optimization technology of frequency conversion constant pressure control system of mine emulsion pump station in electrical engineering and automation specialty
url http://dx.doi.org/10.1155/2021/5569994
work_keys_str_mv AT congtian optimizationtechnologyoffrequencyconversionconstantpressurecontrolsystemofmineemulsionpumpstationinelectricalengineeringandautomationspecialty
AT xiwenwei optimizationtechnologyoffrequencyconversionconstantpressurecontrolsystemofmineemulsionpumpstationinelectricalengineeringandautomationspecialty
AT chaoyang optimizationtechnologyoffrequencyconversionconstantpressurecontrolsystemofmineemulsionpumpstationinelectricalengineeringandautomationspecialty
AT changsu optimizationtechnologyoffrequencyconversionconstantpressurecontrolsystemofmineemulsionpumpstationinelectricalengineeringandautomationspecialty