COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE

The study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads t...

Full description

Saved in:
Bibliographic Details
Main Authors: A. K. Tyavlovsky, A. L. Zharin
Format: Article
Language:English
Published: Belarusian National Technical University 2015-03-01
Series:Приборы и методы измерений
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/36
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543556178280448
author A. K. Tyavlovsky
A. L. Zharin
author_facet A. K. Tyavlovsky
A. L. Zharin
author_sort A. K. Tyavlovsky
collection DOAJ
description The study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads to high measurement errors. The way to lower measurement errors is to register measurement signal on its second harmonic and to control the probe-to-sample gap by monitoring the ratio between the second and the first harmonics’ amplitudes.
format Article
id doaj-art-3de4796d043246408cbf1612cbfff752
institution Kabale University
issn 2220-9506
2414-0473
language English
publishDate 2015-03-01
publisher Belarusian National Technical University
record_format Article
series Приборы и методы измерений
spelling doaj-art-3de4796d043246408cbf1612cbfff7522025-02-03T11:37:45ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732015-03-0102354130COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBEA. K. Tyavlovsky0A. L. Zharin1Белорусский национальный технический университетБелорусский национальный технический университетThe study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads to high measurement errors. The way to lower measurement errors is to register measurement signal on its second harmonic and to control the probe-to-sample gap by monitoring the ratio between the second and the first harmonics’ amplitudes.https://pimi.bntu.by/jour/article/view/36kelvin probevibrating-plate capacitorcomplex-harmonic analysis
spellingShingle A. K. Tyavlovsky
A. L. Zharin
COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
Приборы и методы измерений
kelvin probe
vibrating-plate capacitor
complex-harmonic analysis
title COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_full COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_fullStr COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_full_unstemmed COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_short COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_sort compensation of measurement errors when reducing linear dimensions of the kelvin probe
topic kelvin probe
vibrating-plate capacitor
complex-harmonic analysis
url https://pimi.bntu.by/jour/article/view/36
work_keys_str_mv AT aktyavlovsky compensationofmeasurementerrorswhenreducinglineardimensionsofthekelvinprobe
AT alzharin compensationofmeasurementerrorswhenreducinglineardimensionsofthekelvinprobe