Massive Deposition and Accumulation of Hydroxyapatite Crystal after Total Hip Arthroplasty: A Case Report
We presented a case in which massive hydroxyapatite accumulation was observed around the artificial hip joint. A 66-year-old female showed a massive accumulation of fluid in and around the hip joint, and milk-like aspirate was obtained. Her aspirate culture was negative, and sediment analysis by X-...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Case Reports in Orthopedics |
Online Access: | http://dx.doi.org/10.1155/2013/305180 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We presented a case in which massive hydroxyapatite accumulation was observed around the artificial hip joint. A 66-year-old female showed a massive accumulation of fluid in and around the hip joint, and milk-like aspirate was obtained. Her aspirate culture was negative, and sediment analysis by X-ray diffraction showed that its component was hydroxyapatite. Since pain was mild, the patient was treated conservatively. To our knowledge, this is the first case in which liquid hydroxyapatite (milk of calcium) was accumulated around the artificial hip joint. |
---|---|