Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent
A procedure for removal and separation of Cs, Eu and activation product of Co using zirconium selenomolybdate was developed. Interactions of 134Cs(I), 152,154Eu(III), and 60Co(II) ions from HNO3 acid solutions with zirconium selenomolybdate matrix, dried at 50°C, have been individually investigated...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Journal of Chemistry |
Online Access: | http://dx.doi.org/10.1155/2013/756876 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832558514404327424 |
---|---|
author | H. El-Said |
author_facet | H. El-Said |
author_sort | H. El-Said |
collection | DOAJ |
description | A procedure for removal and separation of Cs, Eu and activation product of Co using zirconium selenomolybdate was developed. Interactions of 134Cs(I), 152,154Eu(III), and 60Co(II) ions from HNO3 acid solutions with zirconium selenomolybdate matrix, dried at 50°C, have been individually investigated by the batch equilibration method. The sorption behavior of the three ions showed a selectivity sequence in the following order: Cs(I) > Eu(III) > Co(II). The breakthrough capacities of zirconium selenomolybdate for Cs(I), Eu(III) and Co(II) were found to be 0.82, 0.45, and 0.18 mmol/g of the sorbent, respectively. A mixture of the three radionuclides (1×10−2 M each) in 140 mL of 1×10−2 M HNO3 solution was passed through 1 g zirconium selenomolybdate chromatographic column. Thereafter, quantitative elution of the retained Co(II) was achieved with 14 mL of 1×10−1 M HNO3 acid solution leaving Eu(III) and Cs(I) strongly retained onto the column. Quantitative elution of Eu(III) was achieved by passing 22 mL 2.5×10−1 M HNO3. About 89% of the retained Cs(I) was eluted with 32 mL of 2 M NH4Cl solution at a flow rate of 0.5 mL/min. |
format | Article |
id | doaj-art-3d3db182c9924e80b06a9fc4655ab829 |
institution | Kabale University |
issn | 2090-9063 2090-9071 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Chemistry |
spelling | doaj-art-3d3db182c9924e80b06a9fc4655ab8292025-02-03T01:32:12ZengWileyJournal of Chemistry2090-90632090-90712013-01-01201310.1155/2013/756876756876Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate SorbentH. El-Said0Radioactive Isotopes and Generators Department, Hot Laboratories Center, Atomic Energy Authority, Cairo 13759, EgyptA procedure for removal and separation of Cs, Eu and activation product of Co using zirconium selenomolybdate was developed. Interactions of 134Cs(I), 152,154Eu(III), and 60Co(II) ions from HNO3 acid solutions with zirconium selenomolybdate matrix, dried at 50°C, have been individually investigated by the batch equilibration method. The sorption behavior of the three ions showed a selectivity sequence in the following order: Cs(I) > Eu(III) > Co(II). The breakthrough capacities of zirconium selenomolybdate for Cs(I), Eu(III) and Co(II) were found to be 0.82, 0.45, and 0.18 mmol/g of the sorbent, respectively. A mixture of the three radionuclides (1×10−2 M each) in 140 mL of 1×10−2 M HNO3 solution was passed through 1 g zirconium selenomolybdate chromatographic column. Thereafter, quantitative elution of the retained Co(II) was achieved with 14 mL of 1×10−1 M HNO3 acid solution leaving Eu(III) and Cs(I) strongly retained onto the column. Quantitative elution of Eu(III) was achieved by passing 22 mL 2.5×10−1 M HNO3. About 89% of the retained Cs(I) was eluted with 32 mL of 2 M NH4Cl solution at a flow rate of 0.5 mL/min.http://dx.doi.org/10.1155/2013/756876 |
spellingShingle | H. El-Said Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent Journal of Chemistry |
title | Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent |
title_full | Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent |
title_fullStr | Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent |
title_full_unstemmed | Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent |
title_short | Radiochemical Studies on the Separation of Cesium, Cobalt, and Europium from Aqueous Solutions Using Zirconium Selenomolybdate Sorbent |
title_sort | radiochemical studies on the separation of cesium cobalt and europium from aqueous solutions using zirconium selenomolybdate sorbent |
url | http://dx.doi.org/10.1155/2013/756876 |
work_keys_str_mv | AT helsaid radiochemicalstudiesontheseparationofcesiumcobaltandeuropiumfromaqueoussolutionsusingzirconiumselenomolybdatesorbent |