Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
Objective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between acce...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2020-01-01
|
Series: | Journal of Nutrition and Metabolism |
Online Access: | http://dx.doi.org/10.1155/2020/2327017 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832566469959876608 |
---|---|
author | Silvia Pisanu Andrea Deledda Andrea Loviselli Inge Huybrechts Fernanda Velluzzi |
author_facet | Silvia Pisanu Andrea Deledda Andrea Loviselli Inge Huybrechts Fernanda Velluzzi |
author_sort | Silvia Pisanu |
collection | DOAJ |
description | Objective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals. Methods. The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool. Results. We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland–Altman plots. Conclusions. Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers. |
format | Article |
id | doaj-art-3d2afca70d544f0cb08d380babd24c37 |
institution | Kabale University |
issn | 2090-0724 2090-0732 |
language | English |
publishDate | 2020-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Nutrition and Metabolism |
spelling | doaj-art-3d2afca70d544f0cb08d380babd24c372025-02-03T01:04:07ZengWileyJournal of Nutrition and Metabolism2090-07242090-07322020-01-01202010.1155/2020/23270172327017Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic ReviewSilvia Pisanu0Andrea Deledda1Andrea Loviselli2Inge Huybrechts3Fernanda Velluzzi4Department of Biomedical Sciences, University of Cagliari, Cagliari, ItalyDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyInternational Agency for Research on Cancer, Nutrition and Metabolism Section, Lyon, FranceDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyObjective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals. Methods. The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool. Results. We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland–Altman plots. Conclusions. Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers.http://dx.doi.org/10.1155/2020/2327017 |
spellingShingle | Silvia Pisanu Andrea Deledda Andrea Loviselli Inge Huybrechts Fernanda Velluzzi Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review Journal of Nutrition and Metabolism |
title | Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review |
title_full | Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review |
title_fullStr | Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review |
title_full_unstemmed | Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review |
title_short | Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review |
title_sort | validity of accelerometers for the evaluation of energy expenditure in obese and overweight individuals a systematic review |
url | http://dx.doi.org/10.1155/2020/2327017 |
work_keys_str_mv | AT silviapisanu validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview AT andreadeledda validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview AT andrealoviselli validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview AT ingehuybrechts validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview AT fernandavelluzzi validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview |