Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review

Objective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between acce...

Full description

Saved in:
Bibliographic Details
Main Authors: Silvia Pisanu, Andrea Deledda, Andrea Loviselli, Inge Huybrechts, Fernanda Velluzzi
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Journal of Nutrition and Metabolism
Online Access:http://dx.doi.org/10.1155/2020/2327017
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566469959876608
author Silvia Pisanu
Andrea Deledda
Andrea Loviselli
Inge Huybrechts
Fernanda Velluzzi
author_facet Silvia Pisanu
Andrea Deledda
Andrea Loviselli
Inge Huybrechts
Fernanda Velluzzi
author_sort Silvia Pisanu
collection DOAJ
description Objective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals. Methods. The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool. Results. We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland–Altman plots. Conclusions. Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers.
format Article
id doaj-art-3d2afca70d544f0cb08d380babd24c37
institution Kabale University
issn 2090-0724
2090-0732
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Journal of Nutrition and Metabolism
spelling doaj-art-3d2afca70d544f0cb08d380babd24c372025-02-03T01:04:07ZengWileyJournal of Nutrition and Metabolism2090-07242090-07322020-01-01202010.1155/2020/23270172327017Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic ReviewSilvia Pisanu0Andrea Deledda1Andrea Loviselli2Inge Huybrechts3Fernanda Velluzzi4Department of Biomedical Sciences, University of Cagliari, Cagliari, ItalyDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyInternational Agency for Research on Cancer, Nutrition and Metabolism Section, Lyon, FranceDepartment of Medical Sciences and Public Health, University of Cagliari, Cagliari, ItalyObjective. Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals. Methods. The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool. Results. We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland–Altman plots. Conclusions. Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers.http://dx.doi.org/10.1155/2020/2327017
spellingShingle Silvia Pisanu
Andrea Deledda
Andrea Loviselli
Inge Huybrechts
Fernanda Velluzzi
Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
Journal of Nutrition and Metabolism
title Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
title_full Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
title_fullStr Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
title_full_unstemmed Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
title_short Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review
title_sort validity of accelerometers for the evaluation of energy expenditure in obese and overweight individuals a systematic review
url http://dx.doi.org/10.1155/2020/2327017
work_keys_str_mv AT silviapisanu validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview
AT andreadeledda validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview
AT andrealoviselli validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview
AT ingehuybrechts validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview
AT fernandavelluzzi validityofaccelerometersfortheevaluationofenergyexpenditureinobeseandoverweightindividualsasystematicreview