Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes

Objectives: To determine the utility of umbilical venous lactate measurements for predicting poor neonatal outcomes. Method: This observational study was conducted at Kahuta Research Laboratories (KRL) hospital, Islamabad from May 2019 to October 2019. Singleton pregnancies with no known fetal co...

Full description

Saved in:
Bibliographic Details
Main Authors: Maria Habib, Maliha Akhtar Qureshi, Irum Sohail
Format: Article
Language:English
Published: Rawalpindi Medical University 2024-03-01
Series:Journal of Rawalpindi Medical College
Online Access:https://www.journalrmc.com/index.php/JRMC/article/view/2018
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832086913493762048
author Maria Habib
Maliha Akhtar Qureshi
Irum Sohail
author_facet Maria Habib
Maliha Akhtar Qureshi
Irum Sohail
author_sort Maria Habib
collection DOAJ
description Objectives: To determine the utility of umbilical venous lactate measurements for predicting poor neonatal outcomes. Method: This observational study was conducted at Kahuta Research Laboratories (KRL) hospital, Islamabad from May 2019 to October 2019. Singleton pregnancies with no known fetal congenital anomalies and gestational age greater than 28 weeks were included. Descriptive statistics were used to analyse the characteristics of study subjects and also composite neonatal outcomes. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Result: Umbilical venous lactate levels were found to be highest in instrumental deliveries (48.7%) and lowest in those delivered by elective cesarean section (25.7%). Low APGAR score, need for initial resuscitation & neonatal intensive care unit admission, mechanical ventilation and neonatal morbidity were all associated with significantly higher lactate levels. Based on the maximal yield index, the optimal cut-off point for predicting neonatal morbidity was 46.5mg/dl (area under the receiver operating characteristics curve was 0.8). Based on this optimal cut-off point, it has a sensitivity of 62%, specificity of 92%, PPV 51% and NPV 94% for neonatal morbidity. Conclusion: Umbilical venous lactate measurement is a good predictor of poor neonatal outcome especially in situations when umbilical arterial blood cannot be taken due to technical difficulty. Mode of delivery has a strong association with fetal hypoxia and raised umbilical lactate levels. Keywords: lactate, neonatal outcomes, labour ward.
format Article
id doaj-art-3cf28c0a46df4c5cac68c51f08c13589
institution Kabale University
issn 1683-3562
1683-3570
language English
publishDate 2024-03-01
publisher Rawalpindi Medical University
record_format Article
series Journal of Rawalpindi Medical College
spelling doaj-art-3cf28c0a46df4c5cac68c51f08c135892025-02-06T08:39:42ZengRawalpindi Medical UniversityJournal of Rawalpindi Medical College1683-35621683-35702024-03-0128110.37939/jrmc.v1i1.2018Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal OutcomesMaria HabibMaliha Akhtar QureshiIrum Sohail Objectives: To determine the utility of umbilical venous lactate measurements for predicting poor neonatal outcomes. Method: This observational study was conducted at Kahuta Research Laboratories (KRL) hospital, Islamabad from May 2019 to October 2019. Singleton pregnancies with no known fetal congenital anomalies and gestational age greater than 28 weeks were included. Descriptive statistics were used to analyse the characteristics of study subjects and also composite neonatal outcomes. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Result: Umbilical venous lactate levels were found to be highest in instrumental deliveries (48.7%) and lowest in those delivered by elective cesarean section (25.7%). Low APGAR score, need for initial resuscitation & neonatal intensive care unit admission, mechanical ventilation and neonatal morbidity were all associated with significantly higher lactate levels. Based on the maximal yield index, the optimal cut-off point for predicting neonatal morbidity was 46.5mg/dl (area under the receiver operating characteristics curve was 0.8). Based on this optimal cut-off point, it has a sensitivity of 62%, specificity of 92%, PPV 51% and NPV 94% for neonatal morbidity. Conclusion: Umbilical venous lactate measurement is a good predictor of poor neonatal outcome especially in situations when umbilical arterial blood cannot be taken due to technical difficulty. Mode of delivery has a strong association with fetal hypoxia and raised umbilical lactate levels. Keywords: lactate, neonatal outcomes, labour ward. https://www.journalrmc.com/index.php/JRMC/article/view/2018
spellingShingle Maria Habib
Maliha Akhtar Qureshi
Irum Sohail
Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
Journal of Rawalpindi Medical College
title Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
title_full Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
title_fullStr Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
title_full_unstemmed Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
title_short Measurement Of Umbilical Venous Lactate Levels For Predicting Poor Neonatal Outcomes
title_sort measurement of umbilical venous lactate levels for predicting poor neonatal outcomes
url https://www.journalrmc.com/index.php/JRMC/article/view/2018
work_keys_str_mv AT mariahabib measurementofumbilicalvenouslactatelevelsforpredictingpoorneonataloutcomes
AT malihaakhtarqureshi measurementofumbilicalvenouslactatelevelsforpredictingpoorneonataloutcomes
AT irumsohail measurementofumbilicalvenouslactatelevelsforpredictingpoorneonataloutcomes