Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor

Fluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted be...

Full description

Saved in:
Bibliographic Details
Main Authors: Hawra Abdulmajeed, Esam Bakir
Format: Article
Language:English
Published: Elsevier 2025-01-01
Series:Results in Chemistry
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2211715624006970
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832583080420835328
author Hawra Abdulmajeed
Esam Bakir
author_facet Hawra Abdulmajeed
Esam Bakir
author_sort Hawra Abdulmajeed
collection DOAJ
description Fluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted between the fluorescence emission of the receptor at λ = 633 nm versus the Co2+ concentration. The detection (LOD) and quantitation (LOQ) limits were determined to be 04.95 and 14.97 µM (R2 = 0.99), respectively. The selectivity of suggested method was obtained for Co2+ outweighs that of transition metal cations with 2 % significant interference with Ni2+. The recovery of the Co(II) ions founded 99.6 %. The experiments and electronic surface mapping(ESP) were illustrated the chemical reactivity of receptor and Co(II). The Co(II) was attached to CO rather than −NCS group of the receptor. The proposed method was successes in the determination of Co(II) in the environmental water sample.
format Article
id doaj-art-3c77576955da45b5af1ed6b3557d4c95
institution Kabale University
issn 2211-7156
language English
publishDate 2025-01-01
publisher Elsevier
record_format Article
series Results in Chemistry
spelling doaj-art-3c77576955da45b5af1ed6b3557d4c952025-01-29T05:00:52ZengElsevierResults in Chemistry2211-71562025-01-0113102001Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptorHawra Abdulmajeed0Esam Bakir1Department of Chemistry, College of Science, King Faisal University, 31982 AlAhsa, Saudi ArabiaCorresponding author.; Department of Chemistry, College of Science, King Faisal University, 31982 AlAhsa, Saudi ArabiaFluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted between the fluorescence emission of the receptor at λ = 633 nm versus the Co2+ concentration. The detection (LOD) and quantitation (LOQ) limits were determined to be 04.95 and 14.97 µM (R2 = 0.99), respectively. The selectivity of suggested method was obtained for Co2+ outweighs that of transition metal cations with 2 % significant interference with Ni2+. The recovery of the Co(II) ions founded 99.6 %. The experiments and electronic surface mapping(ESP) were illustrated the chemical reactivity of receptor and Co(II). The Co(II) was attached to CO rather than −NCS group of the receptor. The proposed method was successes in the determination of Co(II) in the environmental water sample.http://www.sciencedirect.com/science/article/pii/S2211715624006970Fluorometric assayReceptor Ru(dcpy)2(SCN)2Co(II) ionESP(electron surface mapping)
spellingShingle Hawra Abdulmajeed
Esam Bakir
Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
Results in Chemistry
Fluorometric assay
Receptor Ru(dcpy)2(SCN)2
Co(II) ion
ESP(electron surface mapping)
title Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
title_full Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
title_fullStr Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
title_full_unstemmed Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
title_short Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
title_sort spectrofluorometric method for sensing cobalt ii ion in environmental sample using ru dcpy 2 scn 2 receptor
topic Fluorometric assay
Receptor Ru(dcpy)2(SCN)2
Co(II) ion
ESP(electron surface mapping)
url http://www.sciencedirect.com/science/article/pii/S2211715624006970
work_keys_str_mv AT hawraabdulmajeed spectrofluorometricmethodforsensingcobaltiiioninenvironmentalsampleusingrudcpy2scn2receptor
AT esambakir spectrofluorometricmethodforsensingcobaltiiioninenvironmentalsampleusingrudcpy2scn2receptor