Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor
Fluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted be...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-01-01
|
Series: | Results in Chemistry |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2211715624006970 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832583080420835328 |
---|---|
author | Hawra Abdulmajeed Esam Bakir |
author_facet | Hawra Abdulmajeed Esam Bakir |
author_sort | Hawra Abdulmajeed |
collection | DOAJ |
description | Fluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted between the fluorescence emission of the receptor at λ = 633 nm versus the Co2+ concentration. The detection (LOD) and quantitation (LOQ) limits were determined to be 04.95 and 14.97 µM (R2 = 0.99), respectively. The selectivity of suggested method was obtained for Co2+ outweighs that of transition metal cations with 2 % significant interference with Ni2+. The recovery of the Co(II) ions founded 99.6 %. The experiments and electronic surface mapping(ESP) were illustrated the chemical reactivity of receptor and Co(II). The Co(II) was attached to CO rather than −NCS group of the receptor. The proposed method was successes in the determination of Co(II) in the environmental water sample. |
format | Article |
id | doaj-art-3c77576955da45b5af1ed6b3557d4c95 |
institution | Kabale University |
issn | 2211-7156 |
language | English |
publishDate | 2025-01-01 |
publisher | Elsevier |
record_format | Article |
series | Results in Chemistry |
spelling | doaj-art-3c77576955da45b5af1ed6b3557d4c952025-01-29T05:00:52ZengElsevierResults in Chemistry2211-71562025-01-0113102001Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptorHawra Abdulmajeed0Esam Bakir1Department of Chemistry, College of Science, King Faisal University, 31982 AlAhsa, Saudi ArabiaCorresponding author.; Department of Chemistry, College of Science, King Faisal University, 31982 AlAhsa, Saudi ArabiaFluorometric assay was employed for the detection of Co2+ ions based on their rapid reaction with Ru(dcpy)2(SCN)2 as the receptor in acetate buffer solution (pH = 3.50). A high fluorescence intensity of the receptor was observed in an acetate buffer at pH = 3.50. The calibration curve was plotted between the fluorescence emission of the receptor at λ = 633 nm versus the Co2+ concentration. The detection (LOD) and quantitation (LOQ) limits were determined to be 04.95 and 14.97 µM (R2 = 0.99), respectively. The selectivity of suggested method was obtained for Co2+ outweighs that of transition metal cations with 2 % significant interference with Ni2+. The recovery of the Co(II) ions founded 99.6 %. The experiments and electronic surface mapping(ESP) were illustrated the chemical reactivity of receptor and Co(II). The Co(II) was attached to CO rather than −NCS group of the receptor. The proposed method was successes in the determination of Co(II) in the environmental water sample.http://www.sciencedirect.com/science/article/pii/S2211715624006970Fluorometric assayReceptor Ru(dcpy)2(SCN)2Co(II) ionESP(electron surface mapping) |
spellingShingle | Hawra Abdulmajeed Esam Bakir Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor Results in Chemistry Fluorometric assay Receptor Ru(dcpy)2(SCN)2 Co(II) ion ESP(electron surface mapping) |
title | Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor |
title_full | Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor |
title_fullStr | Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor |
title_full_unstemmed | Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor |
title_short | Spectrofluorometric method for sensing cobalt (II) ion in environmental sample using Ru(dcpy)2(SCN)2 receptor |
title_sort | spectrofluorometric method for sensing cobalt ii ion in environmental sample using ru dcpy 2 scn 2 receptor |
topic | Fluorometric assay Receptor Ru(dcpy)2(SCN)2 Co(II) ion ESP(electron surface mapping) |
url | http://www.sciencedirect.com/science/article/pii/S2211715624006970 |
work_keys_str_mv | AT hawraabdulmajeed spectrofluorometricmethodforsensingcobaltiiioninenvironmentalsampleusingrudcpy2scn2receptor AT esambakir spectrofluorometricmethodforsensingcobaltiiioninenvironmentalsampleusingrudcpy2scn2receptor |