A framework for modelling whole-lung and regional transfer factor of the lung for carbon monoxide using hyperpolarised xenon-129 lung magnetic resonance imaging

Background Pulmonary gas exchange is assessed by the transfer factor of the lungs (TL) for carbon monoxide (TLCO), and can also be measured with inhaled xenon-129 (129Xe) magnetic resonance imaging (MRI). A model has been proposed to estimate TL from 129Xe MRI metrics, but this approach has not been...

Full description

Saved in:
Bibliographic Details
Main Authors: Jemima H. Pilgrim-Morris, Laurie J. Smith, Helen Marshall, Bilal A. Tahir, Guilhem J. Collier, Neil J. Stewart, Jim M. Wild
Format: Article
Language:English
Published: European Respiratory Society 2025-02-01
Series:ERJ Open Research
Online Access:http://openres.ersjournals.com/content/11/1/00442-2024.full
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Pulmonary gas exchange is assessed by the transfer factor of the lungs (TL) for carbon monoxide (TLCO), and can also be measured with inhaled xenon-129 (129Xe) magnetic resonance imaging (MRI). A model has been proposed to estimate TL from 129Xe MRI metrics, but this approach has not been fully validated and does not utilise the spatial information provided by three-dimensional 129Xe MRI. Methods Three models for predicting TL from 129Xe MRI metrics were compared: 1) a previously-published physiology-based model, 2) multivariable linear regression and 3) random forest regression. Models were trained on data from 150 patients with asthma and/or COPD. The random forest model was applied voxel-wise to 129Xe images to yield regional TL maps. Results Coefficients of the physiological model were found to differ from previously reported values. All models had good prediction accuracy with small mean absolute error (MAE): 1) 1.24±0.15 mmol·min−1·kPa−1, 2) 1.01±0.06 mmol·min−1·kPa−1, 3) 0.995±0.129 mmol·min−1·kPa−1. The random forest model performed well when applied to a validation group of post-COVID-19 patients and healthy volunteers (MAE=0.840 mmol·min−1·kPa−1), suggesting good generalisability. The feasibility of producing regional maps of predicted TL was demonstrated and the whole-lung sum of the TL maps agreed with measured TLCO (MAE=1.18 mmol·min−1·kPa−1). Conclusion The best prediction of TLCO from 129Xe MRI metrics was with a random forest regression framework. Applying this model on a voxel-wise level to create parametric TL maps provides a useful tool for regional visualisation and clinical interpretation of 129Xe gas exchange MRI.
ISSN:2312-0541