The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve
High precision is necessary during percutaneous transcatheter heart valve implantation. The precision of the implantation has been established by increasing the heart rate (usually to 200 beats per minute) to the point of significantly reduced cardiac output and thus minimizing valve movement. Routi...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2017-01-01
|
Series: | Case Reports in Cardiology |
Online Access: | http://dx.doi.org/10.1155/2017/2760580 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550612554743808 |
---|---|
author | Vicki Zeniou Shmuel Chen Mony Shuvy David Luria Chaim Lotan Haim D. Danenberg |
author_facet | Vicki Zeniou Shmuel Chen Mony Shuvy David Luria Chaim Lotan Haim D. Danenberg |
author_sort | Vicki Zeniou |
collection | DOAJ |
description | High precision is necessary during percutaneous transcatheter heart valve implantation. The precision of the implantation has been established by increasing the heart rate (usually to 200 beats per minute) to the point of significantly reduced cardiac output and thus minimizing valve movement. Routinely, this tachycardia is induced by rapid pacing. Here we report a case of failure to pace during valve-in-valve (VIV) Edwards Sapien XT implantation in the tricuspid valve position. Transient cardiac arrest was induced by intravenous adenosine injection enabling accurate valve implantation. |
format | Article |
id | doaj-art-3a8324e76c2d49a7ad53e552f3dc751d |
institution | Kabale University |
issn | 2090-6404 2090-6412 |
language | English |
publishDate | 2017-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Cardiology |
spelling | doaj-art-3a8324e76c2d49a7ad53e552f3dc751d2025-02-03T06:06:11ZengWileyCase Reports in Cardiology2090-64042090-64122017-01-01201710.1155/2017/27605802760580The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid ValveVicki Zeniou0Shmuel Chen1Mony Shuvy2David Luria3Chaim Lotan4Haim D. Danenberg5Hadassah Hebrew University Medical Center, Jerusalem, IsraelHadassah Hebrew University Medical Center, Jerusalem, IsraelHadassah Hebrew University Medical Center, Jerusalem, IsraelHadassah Hebrew University Medical Center, Jerusalem, IsraelHadassah Hebrew University Medical Center, Jerusalem, IsraelHadassah Hebrew University Medical Center, Jerusalem, IsraelHigh precision is necessary during percutaneous transcatheter heart valve implantation. The precision of the implantation has been established by increasing the heart rate (usually to 200 beats per minute) to the point of significantly reduced cardiac output and thus minimizing valve movement. Routinely, this tachycardia is induced by rapid pacing. Here we report a case of failure to pace during valve-in-valve (VIV) Edwards Sapien XT implantation in the tricuspid valve position. Transient cardiac arrest was induced by intravenous adenosine injection enabling accurate valve implantation.http://dx.doi.org/10.1155/2017/2760580 |
spellingShingle | Vicki Zeniou Shmuel Chen Mony Shuvy David Luria Chaim Lotan Haim D. Danenberg The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve Case Reports in Cardiology |
title | The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve |
title_full | The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve |
title_fullStr | The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve |
title_full_unstemmed | The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve |
title_short | The Use of Adenosine to Enable Safe Implantation of Transcatheter Tricuspid Valve |
title_sort | use of adenosine to enable safe implantation of transcatheter tricuspid valve |
url | http://dx.doi.org/10.1155/2017/2760580 |
work_keys_str_mv | AT vickizeniou theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT shmuelchen theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT monyshuvy theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT davidluria theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT chaimlotan theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT haimddanenberg theuseofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT vickizeniou useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT shmuelchen useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT monyshuvy useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT davidluria useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT chaimlotan useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve AT haimddanenberg useofadenosinetoenablesafeimplantationoftranscathetertricuspidvalve |