CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS
The problem of maintaining a constant gravitational gradient in a relatively large volume of space is considered. This provides a well defined input signal to a gravity gradiometer for the purpose of its calibration. A comparison between gravitational gradients created by straight cy...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Belarusian National Technical University
2015-04-01
|
Series: | Приборы и методы измерений |
Online Access: | https://pimi.bntu.by/jour/article/view/170 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543627321016320 |
---|---|
author | I. Z. Gilavdary A. Veryaskin |
author_facet | I. Z. Gilavdary A. Veryaskin |
author_sort | I. Z. Gilavdary |
collection | DOAJ |
description | The problem of maintaining a constant gravitational gradient in a relatively large volume of space is considered. This provides a well defined input signal to a gravity gradiometer for the purpose of its calibration. A comparison between gravitational gradients created by straight cylinders and spheres is also provided. |
format | Article |
id | doaj-art-3a64684c6b424513977564a62f0a1a44 |
institution | Kabale University |
issn | 2220-9506 2414-0473 |
language | English |
publishDate | 2015-04-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Приборы и методы измерений |
spelling | doaj-art-3a64684c6b424513977564a62f0a1a442025-02-03T11:37:42ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732015-04-0101919710.21122/2220-9506-2011-0-1-124-126164CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERSI. Z. Gilavdary0A. Veryaskin1Белорусский национальный технический университетGravitec Instruments Ltd. Trinity Research Labs. School of Physics University of Western AustraliaThe problem of maintaining a constant gravitational gradient in a relatively large volume of space is considered. This provides a well defined input signal to a gravity gradiometer for the purpose of its calibration. A comparison between gravitational gradients created by straight cylinders and spheres is also provided.https://pimi.bntu.by/jour/article/view/170 |
spellingShingle | I. Z. Gilavdary A. Veryaskin CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS Приборы и методы измерений |
title | CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS |
title_full | CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS |
title_fullStr | CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS |
title_full_unstemmed | CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS |
title_short | CALIBRATION METHOD FOR GRAVITY GRADIOMETERS BY MEANS OF TWO ROTATING CYLINDERS |
title_sort | calibration method for gravity gradiometers by means of two rotating cylinders |
url | https://pimi.bntu.by/jour/article/view/170 |
work_keys_str_mv | AT izgilavdary calibrationmethodforgravitygradiometersbymeansoftworotatingcylinders AT averyaskin calibrationmethodforgravitygradiometersbymeansoftworotatingcylinders |