ABOUT OPERATION OF POWER TRANSFORMERS
Characteristics of power transformers have been considered in the paper. It has been shown that maximum value of transformer efficiency does nor correspond to minimum of its power losses. It is recommended to apply transformers in the areas which are beyond loading factor, corresponding to maximum e...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2003-06-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/1254 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543696729407488 |
---|---|
author | A. A. Gonchar |
author_facet | A. A. Gonchar |
author_sort | A. A. Gonchar |
collection | DOAJ |
description | Characteristics of power transformers have been considered in the paper. It has been shown that maximum value of transformer efficiency does nor correspond to minimum of its power losses. It is recommended to apply transformers in the areas which are beyond loading factor, corresponding to maximum efficiency. |
format | Article |
id | doaj-art-37c71303385f4a968fba51cb8372bcee |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2003-06-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-37c71303385f4a968fba51cb8372bcee2025-02-03T11:35:15ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412003-06-0103262910.21122/1029-7448-2003-0-3-26-291205ABOUT OPERATION OF POWER TRANSFORMERSA. A. Gonchar0Belarusian National Technical UniversityCharacteristics of power transformers have been considered in the paper. It has been shown that maximum value of transformer efficiency does nor correspond to minimum of its power losses. It is recommended to apply transformers in the areas which are beyond loading factor, corresponding to maximum efficiency.https://energy.bntu.by/jour/article/view/1254 |
spellingShingle | A. A. Gonchar ABOUT OPERATION OF POWER TRANSFORMERS Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | ABOUT OPERATION OF POWER TRANSFORMERS |
title_full | ABOUT OPERATION OF POWER TRANSFORMERS |
title_fullStr | ABOUT OPERATION OF POWER TRANSFORMERS |
title_full_unstemmed | ABOUT OPERATION OF POWER TRANSFORMERS |
title_short | ABOUT OPERATION OF POWER TRANSFORMERS |
title_sort | about operation of power transformers |
url | https://energy.bntu.by/jour/article/view/1254 |
work_keys_str_mv | AT aagonchar aboutoperationofpowertransformers |