MEASUREMENT OF CO AND NO2 GAS CONCENTRATION'S BY MULTISENSOR MICROSYSTEM IN THE MODE OF PULSE HEATING
The most promising for mass use in gas analysis equipment are semiconductor gas sensors due to their high reliability, easy operation and relatively low cost. Power consumption in the single-sensor mode, constant heating is from 250 to 600 W average and in pulsed mode heating – ≤ 20 W. The aim of th...
Saved in:
Main Authors: | O. G. Reutskaya, Y. M. Pleskachevsky |
---|---|
Format: | Article |
Language: | English |
Published: |
Belarusian National Technical University
2017-06-01
|
Series: | Приборы и методы измерений |
Subjects: | |
Online Access: | https://pimi.bntu.by/jour/article/view/310 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
FOUR SENSOR GAS MICROSYSTEM BASED ON POROUS ANODIC ALUMINA SUBSTRATE: DESIGN, FABRICATION TECHNIQUE, SIMULATION
by: O. G. Reutskaya, et al.
Published: (2015-03-01) -
QUANTIFICATION CONTRASTS OF LEXICAL MICROSYSTEMS WITH SYNONYMS SЪVEDETELЬ – POSLUKHЪ (A WITNESS) AND THEIR DERIVATIVES IN THE OLD EAST SLAVIC WRITTEN SOURCES (BASED ON MANUSCRIPT HISTORICAL CORPUS)
by: Oleg F. Zholobov
Published: (2024-12-01) -
PATH ANALYSIS OF PERCEPTION OF HEAT PRESSURE, PULSE RATE, BODY TEMPERATURE AGAINST HEAT STRAIN EVENTS IN WORKERS IN BREM PRODUCTION INDUSTRY
by: Siska Wahyu Handayani, Sri Hernawati, Farida Wahyu Ningtyas
Published: (2021-11-01) -
Comparison of Pocket Pulse Oximeter and Standard Pulse Oximeter With ABG Analysis in Critically Ill Patients
by: Jeswanth Reddy N., et al.
Published: (2021-12-01) -
Ultrafast Airy Beam Generation with a Mode-Locked Fiber Laser
by: Silin Guo, et al.
Published: (2024-12-01)