Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes

The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was...

Full description

Saved in:
Bibliographic Details
Main Authors: M. El Nakla, M. Habib, W. Ahmed, A. Al-Sarkhi, R. Ben Mansour, M. Y. Al-Awwad
Format: Article
Language:English
Published: Wiley 2013-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2013/868163
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832562255028289536
author M. El Nakla
M. Habib
W. Ahmed
A. Al-Sarkhi
R. Ben Mansour
M. Y. Al-Awwad
author_facet M. El Nakla
M. Habib
W. Ahmed
A. Al-Sarkhi
R. Ben Mansour
M. Y. Al-Awwad
author_sort M. El Nakla
collection DOAJ
description The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.
format Article
id doaj-art-3520b2652fc84b94a317a6db9a0275f1
institution Kabale University
issn 1687-6075
1687-6083
language English
publishDate 2013-01-01
publisher Wiley
record_format Article
series Science and Technology of Nuclear Installations
spelling doaj-art-3520b2652fc84b94a317a6db9a0275f12025-02-03T01:23:06ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832013-01-01201310.1155/2013/868163868163Application of the Critical Heat Flux Look-Up Table to Large Diameter TubesM. El Nakla0M. Habib1W. Ahmed2A. Al-Sarkhi3R. Ben Mansour4M. Y. Al-Awwad5Mechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaMechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaMechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaMechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaMechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaConsulting Services Department, Saudi Aramco Oil Company, Dhahran 31261, Saudi ArabiaThe critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.http://dx.doi.org/10.1155/2013/868163
spellingShingle M. El Nakla
M. Habib
W. Ahmed
A. Al-Sarkhi
R. Ben Mansour
M. Y. Al-Awwad
Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
Science and Technology of Nuclear Installations
title Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
title_full Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
title_fullStr Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
title_full_unstemmed Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
title_short Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
title_sort application of the critical heat flux look up table to large diameter tubes
url http://dx.doi.org/10.1155/2013/868163
work_keys_str_mv AT melnakla applicationofthecriticalheatfluxlookuptabletolargediametertubes
AT mhabib applicationofthecriticalheatfluxlookuptabletolargediametertubes
AT wahmed applicationofthecriticalheatfluxlookuptabletolargediametertubes
AT aalsarkhi applicationofthecriticalheatfluxlookuptabletolargediametertubes
AT rbenmansour applicationofthecriticalheatfluxlookuptabletolargediametertubes
AT myalawwad applicationofthecriticalheatfluxlookuptabletolargediametertubes