Three-Random-Point Marking Method for Toric Intraocular Lens Alignment Using the iTrace Aberrometer
Purpose. To evaluate the clinical outcome of the three-random-point (TRP) marking method for toric intraocular lens (IOL) alignment using the iTrace aberrometer (Tracey Technologies Corp., Houston, TX). Setting. Department of Ophthalmology, Guangdong Eye Institute, Guangdong Academy of Medical Scien...
Saved in:
| Main Authors: | Yongyi Niu, Hongliang Lin, Yongjie Qin, Cheng Yang, Yanlei Chen, Jin Zeng, Hongyang Zhang |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2021-01-01
|
| Series: | Journal of Ophthalmology |
| Online Access: | http://dx.doi.org/10.1155/2021/6695454 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
iTrace – A Ray Tracing Aberrometer
by: Ayushi Sinha, et al.
Published: (2019-07-01) -
A New System of Axis Marking for Toric Intraocular Lenses - The Toric Max System
by: Subbaiah Sivagnanam, et al.
Published: (2016-07-01) -
Digital Marking for Toric Intraocular Lenses in a Patient with Cyclodeviation
by: Roland Seif, et al.
Published: (2021-01-01) -
Comparison of the Rotational Stability of Different Toric Intraocular Lens Implants
by: Kate C. Torio, MD, et al.
Published: (2014-12-01) -
Visual Outcome and Intraocular Lens Rotational Stability after Cataract Surgery with Multifocal Toric Intraocular Lens Implantation
by: Ewa Mrukwa-Kominek, et al.