Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways

Introduction. The article is devoted to the study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways. The purpose of the work is to determine the zone of waves propagation of lightning overvoltage impulse along the catenary system, the degree of...

Full description

Saved in:
Bibliographic Details
Main Authors: K. S. Belomestnykh, A. N. Bardin, S. N. Vechkanov, A. A. Krylov
Format: Article
Language:Russian
Published: Joint Stock Company «Railway Scientific and Research Institute» 2022-12-01
Series:Вестник Научно-исследовательского института железнодорожного транспорта
Subjects:
Online Access:https://www.journal-vniizht.ru/jour/article/view/651
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849402054553894912
author K. S. Belomestnykh
A. N. Bardin
S. N. Vechkanov
A. A. Krylov
author_facet K. S. Belomestnykh
A. N. Bardin
S. N. Vechkanov
A. A. Krylov
author_sort K. S. Belomestnykh
collection DOAJ
description Introduction. The article is devoted to the study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways. The purpose of the work is to determine the zone of waves propagation of lightning overvoltage impulse along the catenary system, the degree of attenuation and the influence of the soil condition on the mode of their propagation.Materials and methods. The authors carried out tests on the waves propagation of lightning overvoltage impulse along the catenary system of the 1st (ring) track and the 15th (dead end) track of the Experimental Loop of the Railway Research Institute at the Shcherbinka station using a high-voltage impulse voltage generator.Results. During the tests, the influence of the soil condition on the mode of waves propagation of lightning overvoltage impulse was determined. The degree of attenuation of the lightning overvoltage impulse wave in the catenary system in the looped and dead end sections is determined, considering the influence of the reverse (reflected) overvoltage wave, as well as changes in the voltage level during the wave process occurring in the catenary system. The data obtained during the tests enable to determine the propagation speed of the lightning impulse wave.Discussion and conclusion. The obtained test results will be useful for improving the reliability of lightning protection devices of the catenary system against external overvoltages and can be used to improve insulating elements.
format Article
id doaj-art-3153d60e070e41ad894e1bbdb3dfca4a
institution Kabale University
issn 2223-9731
2713-2560
language Russian
publishDate 2022-12-01
publisher Joint Stock Company «Railway Scientific and Research Institute»
record_format Article
series Вестник Научно-исследовательского института железнодорожного транспорта
spelling doaj-art-3153d60e070e41ad894e1bbdb3dfca4a2025-08-20T03:37:38ZrusJoint Stock Company «Railway Scientific and Research Institute»Вестник Научно-исследовательского института железнодорожного транспорта2223-97312713-25602022-12-0181434835810.21780/2223-9731-2022-81-4-348-358400Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railwaysK. S. Belomestnykh0A. N. Bardin1S. N. Vechkanov2A. A. Krylov3Railway Research InstituteRailway Research InstituteRailway Research InstituteRailway Research InstituteIntroduction. The article is devoted to the study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways. The purpose of the work is to determine the zone of waves propagation of lightning overvoltage impulse along the catenary system, the degree of attenuation and the influence of the soil condition on the mode of their propagation.Materials and methods. The authors carried out tests on the waves propagation of lightning overvoltage impulse along the catenary system of the 1st (ring) track and the 15th (dead end) track of the Experimental Loop of the Railway Research Institute at the Shcherbinka station using a high-voltage impulse voltage generator.Results. During the tests, the influence of the soil condition on the mode of waves propagation of lightning overvoltage impulse was determined. The degree of attenuation of the lightning overvoltage impulse wave in the catenary system in the looped and dead end sections is determined, considering the influence of the reverse (reflected) overvoltage wave, as well as changes in the voltage level during the wave process occurring in the catenary system. The data obtained during the tests enable to determine the propagation speed of the lightning impulse wave.Discussion and conclusion. The obtained test results will be useful for improving the reliability of lightning protection devices of the catenary system against external overvoltages and can be used to improve insulating elements.https://www.journal-vniizht.ru/jour/article/view/651electrified railwayscatenary systemimpulse voltage generatorimpulse voltagedirect lightning strikeinter-substation zonelightning overvoltage impulse waveimpulse propagationimpulse amplitude
spellingShingle K. S. Belomestnykh
A. N. Bardin
S. N. Vechkanov
A. A. Krylov
Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
Вестник Научно-исследовательского института железнодорожного транспорта
electrified railways
catenary system
impulse voltage generator
impulse voltage
direct lightning strike
inter-substation zone
lightning overvoltage impulse wave
impulse propagation
impulse amplitude
title Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
title_full Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
title_fullStr Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
title_full_unstemmed Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
title_short Study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
title_sort study of the waves propagation of lightning overvoltage impulse in the catenary system of electrified railways
topic electrified railways
catenary system
impulse voltage generator
impulse voltage
direct lightning strike
inter-substation zone
lightning overvoltage impulse wave
impulse propagation
impulse amplitude
url https://www.journal-vniizht.ru/jour/article/view/651
work_keys_str_mv AT ksbelomestnykh studyofthewavespropagationoflightningovervoltageimpulseinthecatenarysystemofelectrifiedrailways
AT anbardin studyofthewavespropagationoflightningovervoltageimpulseinthecatenarysystemofelectrifiedrailways
AT snvechkanov studyofthewavespropagationoflightningovervoltageimpulseinthecatenarysystemofelectrifiedrailways
AT aakrylov studyofthewavespropagationoflightningovervoltageimpulseinthecatenarysystemofelectrifiedrailways