Liver perforation caused by modified biliary stent of nasobiliary duct:a case report
There are many cases of biliary stent migration. Generally, biliary stent migrates distally. While, biliary stent rarely migrates proximally. Here we reported the case of a 49-year-old woman who underwent robot assisted right hemihepatectomy, and placement of a biliary stent for complicating bile le...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Surgery Concepts & Practice
2024-09-01
|
Series: | Waike lilun yu shijian |
Subjects: | |
Online Access: | https://www.qk.sjtu.edu.cn/jscp/fileup/1007-9610/PDF/1737619613657-1549009141.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832590592255721472 |
---|---|
author | JIAO Yuanjun, YIN Yaoxin, LI Guixian, LIU Jikui, LIN Zewei |
author_facet | JIAO Yuanjun, YIN Yaoxin, LI Guixian, LIU Jikui, LIN Zewei |
author_sort | JIAO Yuanjun, YIN Yaoxin, LI Guixian, LIU Jikui, LIN Zewei |
collection | DOAJ |
description | There are many cases of biliary stent migration. Generally, biliary stent migrates distally. While, biliary stent rarely migrates proximally. Here we reported the case of a 49-year-old woman who underwent robot assisted right hemihepatectomy, and placement of a biliary stent for complicating bile leakage. The patient was discharged from hospital after recovering from bile leakage. Five months later, a follow-up examination revealed that the biliary stent had shifted into the liver, leading to liver perforation. We fully removed the stent by using a stone retrieval balloon and a snare. We suggested that when useing a biliary stent, it is necessary to consider of appropriate length of the stent and inform the patient when to return to the hospital for stent removal, in order to avoid stent migration and complications occurrence. |
format | Article |
id | doaj-art-304945aba46e4803b284cc191c0182b5 |
institution | Kabale University |
issn | 1007-9610 |
language | zho |
publishDate | 2024-09-01 |
publisher | Editorial Office of Journal of Surgery Concepts & Practice |
record_format | Article |
series | Waike lilun yu shijian |
spelling | doaj-art-304945aba46e4803b284cc191c0182b52025-01-23T10:48:45ZzhoEditorial Office of Journal of Surgery Concepts & PracticeWaike lilun yu shijian1007-96102024-09-01290545245410.16139/j.1007-9610.2024.05.14Liver perforation caused by modified biliary stent of nasobiliary duct:a case reportJIAO Yuanjun, YIN Yaoxin, LI Guixian, LIU Jikui, LIN Zewei0Department of Hepatobiliary and Pancreatic Surgery, Peking University Shenzhen Hospital,Guangdong Shenzhen 518036, ChinaThere are many cases of biliary stent migration. Generally, biliary stent migrates distally. While, biliary stent rarely migrates proximally. Here we reported the case of a 49-year-old woman who underwent robot assisted right hemihepatectomy, and placement of a biliary stent for complicating bile leakage. The patient was discharged from hospital after recovering from bile leakage. Five months later, a follow-up examination revealed that the biliary stent had shifted into the liver, leading to liver perforation. We fully removed the stent by using a stone retrieval balloon and a snare. We suggested that when useing a biliary stent, it is necessary to consider of appropriate length of the stent and inform the patient when to return to the hospital for stent removal, in order to avoid stent migration and complications occurrence.https://www.qk.sjtu.edu.cn/jscp/fileup/1007-9610/PDF/1737619613657-1549009141.pdf|endoscopic retrograde cholangio-pancreatography|bile leakage|biliary stent|complication |
spellingShingle | JIAO Yuanjun, YIN Yaoxin, LI Guixian, LIU Jikui, LIN Zewei Liver perforation caused by modified biliary stent of nasobiliary duct:a case report Waike lilun yu shijian |endoscopic retrograde cholangio-pancreatography|bile leakage|biliary stent|complication |
title | Liver perforation caused by modified biliary stent of nasobiliary duct:a case report |
title_full | Liver perforation caused by modified biliary stent of nasobiliary duct:a case report |
title_fullStr | Liver perforation caused by modified biliary stent of nasobiliary duct:a case report |
title_full_unstemmed | Liver perforation caused by modified biliary stent of nasobiliary duct:a case report |
title_short | Liver perforation caused by modified biliary stent of nasobiliary duct:a case report |
title_sort | liver perforation caused by modified biliary stent of nasobiliary duct a case report |
topic | |endoscopic retrograde cholangio-pancreatography|bile leakage|biliary stent|complication |
url | https://www.qk.sjtu.edu.cn/jscp/fileup/1007-9610/PDF/1737619613657-1549009141.pdf |
work_keys_str_mv | AT jiaoyuanjunyinyaoxinliguixianliujikuilinzewei liverperforationcausedbymodifiedbiliarystentofnasobiliaryductacasereport |