Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018

Turkey has always been exposed to active fault lines passing through and unpredictable seismic activities. These ground movements have always been one of the important issues in our country, which have led to great destruction and loss of lives and property in its past. For this reason, our earthqua...

Full description

Saved in:
Bibliographic Details
Main Authors: Yilmaz Dilek, Abdulhalim Karasin
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2021/6380783
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832545977955778560
author Yilmaz Dilek
Abdulhalim Karasin
author_facet Yilmaz Dilek
Abdulhalim Karasin
author_sort Yilmaz Dilek
collection DOAJ
description Turkey has always been exposed to active fault lines passing through and unpredictable seismic activities. These ground movements have always been one of the important issues in our country, which have led to great destruction and loss of lives and property in its past. For this reason, our earthquake regulations, which aim to design more accurately against earthquake movements, are continuously made improvements. In this study, the analysis of structures built with tunnel formwork system which is popular today with the new earthquake regulations entered into force in 2018, and the strength and cost according to the old earthquake regulation in terms of what differences will occur. In addition to the study, we investigated how the number of floors and regular floor plans affects the results. For this purpose, two types of structures were covered with 5, 10, and 15 storey models created, first in the 2007 earthquake regulation; then, in the 2018 earthquake regulation, design analysis was carried out. As a result, the new earthquake regulation, which came into force in 2018, led to more realistic results as it provides more accurate environmental inputs used in design analysis. Earthquake loads affecting floors increased by 3.9% for 5 storey in regular structures, decreasing by 38.4% for 10 stories and 43.3% for 15 stories. More irregular structures increased 7.3% for 5 storey, 10-storey structures decreased by 38.9%, and 15-storey structures decreased by 43.6%. In terms of cost, there was a 0.07% increase in total cost in 5-storey buildings, 2.45% in 10-storey buildings, and a 3.91% reduction in 15-storey buildings. In addition to these results, an empirical formula that estimates m2 prices depending on the number of floors was obtained.
format Article
id doaj-art-2fa64f49bac541879e369e69aaa582ef
institution Kabale University
issn 1687-8094
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-2fa64f49bac541879e369e69aaa582ef2025-02-03T07:24:14ZengWileyAdvances in Civil Engineering1687-80942021-01-01202110.1155/2021/6380783Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018Yilmaz Dilek0Abdulhalim Karasin1Dicle UniversityDicle UniversityTurkey has always been exposed to active fault lines passing through and unpredictable seismic activities. These ground movements have always been one of the important issues in our country, which have led to great destruction and loss of lives and property in its past. For this reason, our earthquake regulations, which aim to design more accurately against earthquake movements, are continuously made improvements. In this study, the analysis of structures built with tunnel formwork system which is popular today with the new earthquake regulations entered into force in 2018, and the strength and cost according to the old earthquake regulation in terms of what differences will occur. In addition to the study, we investigated how the number of floors and regular floor plans affects the results. For this purpose, two types of structures were covered with 5, 10, and 15 storey models created, first in the 2007 earthquake regulation; then, in the 2018 earthquake regulation, design analysis was carried out. As a result, the new earthquake regulation, which came into force in 2018, led to more realistic results as it provides more accurate environmental inputs used in design analysis. Earthquake loads affecting floors increased by 3.9% for 5 storey in regular structures, decreasing by 38.4% for 10 stories and 43.3% for 15 stories. More irregular structures increased 7.3% for 5 storey, 10-storey structures decreased by 38.9%, and 15-storey structures decreased by 43.6%. In terms of cost, there was a 0.07% increase in total cost in 5-storey buildings, 2.45% in 10-storey buildings, and a 3.91% reduction in 15-storey buildings. In addition to these results, an empirical formula that estimates m2 prices depending on the number of floors was obtained.http://dx.doi.org/10.1155/2021/6380783
spellingShingle Yilmaz Dilek
Abdulhalim Karasin
Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
Advances in Civil Engineering
title Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
title_full Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
title_fullStr Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
title_full_unstemmed Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
title_short Examination of Structures Built with Tunnel Formwork in Terms of Strength and Cost according to the Earthquake Regulations of 2007 and 2018
title_sort examination of structures built with tunnel formwork in terms of strength and cost according to the earthquake regulations of 2007 and 2018
url http://dx.doi.org/10.1155/2021/6380783
work_keys_str_mv AT yilmazdilek examinationofstructuresbuiltwithtunnelformworkintermsofstrengthandcostaccordingtotheearthquakeregulationsof2007and2018
AT abdulhalimkarasin examinationofstructuresbuiltwithtunnelformworkintermsofstrengthandcostaccordingtotheearthquakeregulationsof2007and2018