Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples

In the current paper, an HPLC/UV method was developed and validated for determination of wogonin in plasma. Considerable attention was paid to the preparation of standard samples and factors affecting drug distribution. A preparation procedure was devised to simulate the conditions the drug is expec...

Full description

Saved in:
Bibliographic Details
Main Authors: Salmani Jumah Masoud Mohammad, Wu Xue, Jacob Joe Antony, Fu Rong, Chen Baoan
Format: Article
Language:English
Published: Sciendo 2017-09-01
Series:Acta Pharmaceutica
Subjects:
Online Access:https://doi.org/10.1515/acph-2017-0029
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572121558024192
author Salmani Jumah Masoud Mohammad
Wu Xue
Jacob Joe Antony
Fu Rong
Chen Baoan
author_facet Salmani Jumah Masoud Mohammad
Wu Xue
Jacob Joe Antony
Fu Rong
Chen Baoan
author_sort Salmani Jumah Masoud Mohammad
collection DOAJ
description In the current paper, an HPLC/UV method was developed and validated for determination of wogonin in plasma. Considerable attention was paid to the preparation of standard samples and factors affecting drug distribution. A preparation procedure was devised to simulate the conditions the drug is expected to experience in vivo while pointing to the shortcomings of previously published methods. The method was validated according to the FDA regulations and showed to be highly efficient and capable of extracting the drug and IS from the plasma accurately and precisely within the specified range of 50–500 ng mL−1. Further, the standard sample preparation of this method can be used as a guideline for other methods, particularly when highly hydrophobic drugs with considerable protein binding are involved and could be valuable in the field of bioanalysis to improve the reliability of methods.
format Article
id doaj-art-2ed0ab38fbf64736900aae513ff8c472
institution Kabale University
issn 1846-9558
language English
publishDate 2017-09-01
publisher Sciendo
record_format Article
series Acta Pharmaceutica
spelling doaj-art-2ed0ab38fbf64736900aae513ff8c4722025-02-02T11:50:20ZengSciendoActa Pharmaceutica1846-95582017-09-0167337338410.1515/acph-2017-0029acph-2017-0029Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samplesSalmani Jumah Masoud Mohammad0Wu Xue1Jacob Joe Antony2Fu Rong3Chen Baoan4Department of Hematology and Oncology (Key Department of Jiangsu Medicine), Zhongda Hospital, Medical School, Southeast University, Nanjing, People’s Republic of ChinaDepartment of Hematology and Oncology (Key Department of Jiangsu Medicine), Zhongda Hospital, Medical School, Southeast University, Nanjing, People’s Republic of ChinaDepartment of Hematology and Oncology (Key Department of Jiangsu Medicine), Zhongda Hospital, Medical School, Southeast University, Nanjing, People’s Republic of ChinaState Key Laboratory of Natural Medicines, Jiangsu Key Laboratory of Carcinogenesis and Intervention China Pharmaceutical University, Nanjing, People’s Republic of ChinaDepartment of Hematology and Oncology (Key Department of Jiangsu Medicine), Zhongda Hospital, Medical School, Southeast University, Nanjing, People’s Republic of ChinaIn the current paper, an HPLC/UV method was developed and validated for determination of wogonin in plasma. Considerable attention was paid to the preparation of standard samples and factors affecting drug distribution. A preparation procedure was devised to simulate the conditions the drug is expected to experience in vivo while pointing to the shortcomings of previously published methods. The method was validated according to the FDA regulations and showed to be highly efficient and capable of extracting the drug and IS from the plasma accurately and precisely within the specified range of 50–500 ng mL−1. Further, the standard sample preparation of this method can be used as a guideline for other methods, particularly when highly hydrophobic drugs with considerable protein binding are involved and could be valuable in the field of bioanalysis to improve the reliability of methods.https://doi.org/10.1515/acph-2017-0029wogoninhplc/uvstandard sample preparationsample compatibility
spellingShingle Salmani Jumah Masoud Mohammad
Wu Xue
Jacob Joe Antony
Fu Rong
Chen Baoan
Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
Acta Pharmaceutica
wogonin
hplc/uv
standard sample preparation
sample compatibility
title Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
title_full Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
title_fullStr Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
title_full_unstemmed Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
title_short Development of a new HPLC method for wogonin in rat plasma: Compatibility of standard and test samples
title_sort development of a new hplc method for wogonin in rat plasma compatibility of standard and test samples
topic wogonin
hplc/uv
standard sample preparation
sample compatibility
url https://doi.org/10.1515/acph-2017-0029
work_keys_str_mv AT salmanijumahmasoudmohammad developmentofanewhplcmethodforwogonininratplasmacompatibilityofstandardandtestsamples
AT wuxue developmentofanewhplcmethodforwogonininratplasmacompatibilityofstandardandtestsamples
AT jacobjoeantony developmentofanewhplcmethodforwogonininratplasmacompatibilityofstandardandtestsamples
AT furong developmentofanewhplcmethodforwogonininratplasmacompatibilityofstandardandtestsamples
AT chenbaoan developmentofanewhplcmethodforwogonininratplasmacompatibilityofstandardandtestsamples