Application of Factorial and Doehlert Designs for the Optimization of the Simultaneous Separation and Determination of Antimigraine Drugs in Pharmaceutical Formulations by RP-HPLC-UV

A sensitive, precise, accurate, and specific isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous separation and determination of zolmitriptan, naratriptan, dihydroergotamine, ketotifen, and pizotifen in pharmaceutical formulations has been developed...

Full description

Saved in:
Bibliographic Details
Main Authors: Sami Jebali, Chaouki Belgacem, Mohamed Radhouen Louhaichi, Senda Bahri, Latifa Latrous El Atarche
Format: Article
Language:English
Published: Wiley 2019-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2019/9685750
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A sensitive, precise, accurate, and specific isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous separation and determination of zolmitriptan, naratriptan, dihydroergotamine, ketotifen, and pizotifen in pharmaceutical formulations has been developed and validated. An experimental design was applied for the optimization of the chromatographic parameters. A two-level full factorial 2k was used for studying the interaction between the variables to be optimized: the percentage of acetonitrile in the mobile phase, mobile-phase pH, nature of the buffer, and column oven temperature. The most significant parameters are the percentage of acetonitrile and the mobile-phase pH. These significant parameters were optimized using the Doehlert matrix. The optimum separation was achieved by means of a Waters XBridge C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile and a 10 mM sodium perchlorate buffer (38 : 62, v/v) at a flow rate of 1.0 mL·min−1 and UV detection at 220 nm. The selectivity, method linearity, accuracy, and precision were examined as part of the method validation. The described method shows excellent linearity over a range of 30 to 70 μg·mL−1 for all compounds with correlation coefficients higher than 0.995. The standard deviations of the intraday and interday precision were between 0.75 and 1.94%. The validated method was successfully applied to perform routine analysis of these compounds in different pharmaceutical products such as syrups and tablets. In the presence of some preservatives, it was found that there were no peaks at the related peak locations.
ISSN:1687-8760
1687-8779