Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure

The clinical case of implantation of the left ventricular electrode for resynchronization therapy through a puncture of the interventricular septum with fixation in the cavity of the left ventricle is presented. Due to unsuccessful attempts to introduce an electrode for stimulation of the left ventr...

Full description

Saved in:
Bibliographic Details
Main Authors: B.B. Kravchuk, Yu.І. Karpenko, M.M. Petkanych, O.Z. Paratsii, A.V. Yakushev, R.G. Malyarchuk, V.V. Shapovalova, M.M. Sichik
Format: Article
Language:English
Published: TOV Chetverta Khvylia 2018-11-01
Series:Кардіохірургія та інтервенційна кардіологія
Subjects:
Online Access:http://www.csic.com.ua/images/pdf/2018/4-2018/experience-of-implantation-left-ventricular-electrode-by-means-of-interventricular-septum-puncture.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573275676344320
author B.B. Kravchuk
Yu.І. Karpenko
M.M. Petkanych
O.Z. Paratsii
A.V. Yakushev
R.G. Malyarchuk
V.V. Shapovalova
M.M. Sichik
author_facet B.B. Kravchuk
Yu.І. Karpenko
M.M. Petkanych
O.Z. Paratsii
A.V. Yakushev
R.G. Malyarchuk
V.V. Shapovalova
M.M. Sichik
author_sort B.B. Kravchuk
collection DOAJ
description The clinical case of implantation of the left ventricular electrode for resynchronization therapy through a puncture of the interventricular septum with fixation in the cavity of the left ventricle is presented. Due to unsuccessful attempts to introduce an electrode for stimulation of the left ventricle at the stage of cannulation of the coronary sinus, this technique is used as an alternative. The necessity of continuous administration of warfarin against the background of the prosthetic mechanical aortic valve provided adequate hypocoagulation and absence of clinical signs of thrombosis during the three-month follow-up period in the postoperative period. The use of a puncture of the interventricular septum for implantation of the left ventricular electrode is a safe and effective alternative in patients with complicated or impossible surgical access to the venous system of the heart.
format Article
id doaj-art-2b29778694204aa38a56ab7b6be03041
institution Kabale University
issn 2305-3127
language English
publishDate 2018-11-01
publisher TOV Chetverta Khvylia
record_format Article
series Кардіохірургія та інтервенційна кардіологія
spelling doaj-art-2b29778694204aa38a56ab7b6be030412025-02-02T05:12:43ZengTOV Chetverta KhvyliaКардіохірургія та інтервенційна кардіологія2305-31272018-11-012344246doi.org/10.31928/2305-3127-2018.4.4246Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failureB.B. Kravchuk0Yu.І. Karpenko1M.M. Petkanych2O.Z. Paratsii3A.V. Yakushev4R.G. Malyarchuk5V.V. Shapovalova6M.M. Sichik7M.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineOdesa National Medical University, UkraineM.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineM.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineM.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineM.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineOdesa National Medical University, UkraineM.M. Amosov National Institute of Cardiovascular Surgery of NAMS of Ukraine, Kyiv, UkraineThe clinical case of implantation of the left ventricular electrode for resynchronization therapy through a puncture of the interventricular septum with fixation in the cavity of the left ventricle is presented. Due to unsuccessful attempts to introduce an electrode for stimulation of the left ventricle at the stage of cannulation of the coronary sinus, this technique is used as an alternative. The necessity of continuous administration of warfarin against the background of the prosthetic mechanical aortic valve provided adequate hypocoagulation and absence of clinical signs of thrombosis during the three-month follow-up period in the postoperative period. The use of a puncture of the interventricular septum for implantation of the left ventricular electrode is a safe and effective alternative in patients with complicated or impossible surgical access to the venous system of the heart.http://www.csic.com.ua/images/pdf/2018/4-2018/experience-of-implantation-left-ventricular-electrode-by-means-of-interventricular-septum-puncture.pdfresynchronization therapyleft ventricular stimulation
spellingShingle B.B. Kravchuk
Yu.І. Karpenko
M.M. Petkanych
O.Z. Paratsii
A.V. Yakushev
R.G. Malyarchuk
V.V. Shapovalova
M.M. Sichik
Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
Кардіохірургія та інтервенційна кардіологія
resynchronization therapy
left ventricular stimulation
title Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
title_full Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
title_fullStr Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
title_full_unstemmed Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
title_short Experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
title_sort experience of implantation of the left ventricular electrode by means of interventricular septum puncture for resynchronization therapy in a patient with heart failure
topic resynchronization therapy
left ventricular stimulation
url http://www.csic.com.ua/images/pdf/2018/4-2018/experience-of-implantation-left-ventricular-electrode-by-means-of-interventricular-septum-puncture.pdf
work_keys_str_mv AT bbkravchuk experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT yuíkarpenko experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT mmpetkanych experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT ozparatsii experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT avyakushev experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT rgmalyarchuk experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT vvshapovalova experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure
AT mmsichik experienceofimplantationoftheleftventricularelectrodebymeansofinterventricularseptumpunctureforresynchronizationtherapyinapatientwithheartfailure