High-Frequency and Low-Intensity Patterned Transcranial Magnetic Stimulation over Left Dorsolateral Prefrontal Cortex as Treatment for Major Depressive Disorder: A Report of 3 Cases

Current transcranial magnetic stimulation devices apply intense (near 1 tesla) repetitive magnetic pulses over a specific area of the skull at relatively lower frequencies (1-50 Hz). Nevertheless, different studies have shown that very small magnetic fields, at higher frequencies (50-1000 Hz.), prod...

Full description

Saved in:
Bibliographic Details
Main Authors: Lizbeth Castillo-Aguilar, Alma E. Ríos-Ponce, Edson Albano de Mendonca, Gabriel Villafuerte
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Case Reports in Psychiatry
Online Access:http://dx.doi.org/10.1155/2021/5563017
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Current transcranial magnetic stimulation devices apply intense (near 1 tesla) repetitive magnetic pulses over a specific area of the skull at relatively lower frequencies (1-50 Hz). Nevertheless, different studies have shown that very small magnetic fields, at higher frequencies (50-1000 Hz.), produce therapeutic effects in major depressive disorder. We report the application of high-frequency and low-intensity patterned magnetic pulses over the left prefrontal dorsolateral cortex in three subjects diagnosed with clinical major depressive disorder. All three patients showed sharp changes in their self-reports as well as in the standardized clinical assessment. Hypothesized mechanisms of action of this new variant of magnetic stimulation are discussed.
ISSN:2090-682X
2090-6838