GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM

The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering...

Full description

Saved in:
Bibliographic Details
Main Authors: М.Ю. Артеменко, Ю.В. Кутафін, В.В. Чопик, В.М. Михальський, І.A. Шаповал, С.Й. Поліщук
Format: Article
Language:English
Published: NAS of Ukraine, Institute of elecrodynamics 2025-01-01
Series:Технічна електродинаміка
Subjects:
Online Access:https://techned.org.ua/index.php/techned/article/view/1602
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832590590245601280
author М.Ю. Артеменко
Ю.В. Кутафін
В.В. Чопик
В.М. Михальський
І.A. Шаповал
С.Й. Поліщук
author_facet М.Ю. Артеменко
Ю.В. Кутафін
В.В. Чопик
В.М. Михальський
І.A. Шаповал
С.Й. Поліщук
author_sort М.Ю. Артеменко
collection DOAJ
description The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.
format Article
id doaj-art-29f9eaa4d7da41eb9367343e3d921dcd
institution Kabale University
issn 1607-7970
2218-1903
language English
publishDate 2025-01-01
publisher NAS of Ukraine, Institute of elecrodynamics
record_format Article
series Технічна електродинаміка
spelling doaj-art-29f9eaa4d7da41eb9367343e3d921dcd2025-01-23T10:37:41ZengNAS of Ukraine, Institute of elecrodynamicsТехнічна електродинаміка1607-79702218-19032025-01-01102402410.15407/techned2025.01.0241602GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEMМ.Ю. Артеменко0https://orcid.org/0000-0001-9341-9238Ю.В. Кутафін1https://orcid.org/0000-0002-8156-1277В.В. Чопик2https://orcid.org/0000-0002-5046-5223В.М. Михальський3https://orcid.org/0000-0002-8251-3111І.A. Шаповал4https://orcid.org/0000-0002-9107-5061С.Й. Поліщук5https://orcid.org/0000-0002-6978-2747National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", 37, Beresteiskyi Ave., Kyiv, 03056, UkraineNational Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", 37, Beresteiskyi Ave., Kyiv, 03056, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineThe paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.https://techned.org.ua/index.php/techned/article/view/1602apparent powerpower factorminimization of power lossescontrol strategy for shunt active filterreduced coordinate basis
spellingShingle М.Ю. Артеменко
Ю.В. Кутафін
В.В. Чопик
В.М. Михальський
І.A. Шаповал
С.Й. Поліщук
GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
Технічна електродинаміка
apparent power
power factor
minimization of power losses
control strategy for shunt active filter
reduced coordinate basis
title GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
title_full GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
title_fullStr GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
title_full_unstemmed GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
title_short GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
title_sort generalized definition of the apparent power and energy efficient strategies of active filtration in the reduced coordinate base of a multiphase power supply system
topic apparent power
power factor
minimization of power losses
control strategy for shunt active filter
reduced coordinate basis
url https://techned.org.ua/index.php/techned/article/view/1602
work_keys_str_mv AT mûartemenko generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem
AT ûvkutafín generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem
AT vvčopik generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem
AT vmmihalʹsʹkij generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem
AT íašapoval generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem
AT sjpolíŝuk generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem