GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
NAS of Ukraine, Institute of elecrodynamics
2025-01-01
|
Series: | Технічна електродинаміка |
Subjects: | |
Online Access: | https://techned.org.ua/index.php/techned/article/view/1602 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832590590245601280 |
---|---|
author | М.Ю. Артеменко Ю.В. Кутафін В.В. Чопик В.М. Михальський І.A. Шаповал С.Й. Поліщук |
author_facet | М.Ю. Артеменко Ю.В. Кутафін В.В. Чопик В.М. Михальський І.A. Шаповал С.Й. Поліщук |
author_sort | М.Ю. Артеменко |
collection | DOAJ |
description | The paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2. |
format | Article |
id | doaj-art-29f9eaa4d7da41eb9367343e3d921dcd |
institution | Kabale University |
issn | 1607-7970 2218-1903 |
language | English |
publishDate | 2025-01-01 |
publisher | NAS of Ukraine, Institute of elecrodynamics |
record_format | Article |
series | Технічна електродинаміка |
spelling | doaj-art-29f9eaa4d7da41eb9367343e3d921dcd2025-01-23T10:37:41ZengNAS of Ukraine, Institute of elecrodynamicsТехнічна електродинаміка1607-79702218-19032025-01-01102402410.15407/techned2025.01.0241602GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEMМ.Ю. Артеменко0https://orcid.org/0000-0001-9341-9238Ю.В. Кутафін1https://orcid.org/0000-0002-8156-1277В.В. Чопик2https://orcid.org/0000-0002-5046-5223В.М. Михальський3https://orcid.org/0000-0002-8251-3111І.A. Шаповал4https://orcid.org/0000-0002-9107-5061С.Й. Поліщук5https://orcid.org/0000-0002-6978-2747National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", 37, Beresteiskyi Ave., Kyiv, 03056, UkraineNational Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", 37, Beresteiskyi Ave., Kyiv, 03056, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineInstitute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, UkraineThe paper substantiates the equivalence of determining the apparent power of a multiphase power supply system with different transmission line impedances using the Fryze-Buchholz-Deppenbrock method and on a reduced coordinate basis. Two energy-efficient control strategies for shunt active filtering in the reduced coordinate basis are proposed. The first strategy provides a unit value of the power factor, and the second strategy minimizes power losses in the transmission line while maintaining symmetry and the quasi-sinusoidal shape of the consumed currents. The advantages of using a reduced coordinate basis are a reduction in the number of sensors and key active filter regulators as well as the absence of the problem to organize the artificial grounding point for phase voltage measurements. A correction factor for the apparent power and power factor formulas was determined and verified in the presence of restrictions on the symmetrical and sinusoidal shape of the consumed currents. References 22, figures 5, tables 2.https://techned.org.ua/index.php/techned/article/view/1602apparent powerpower factorminimization of power lossescontrol strategy for shunt active filterreduced coordinate basis |
spellingShingle | М.Ю. Артеменко Ю.В. Кутафін В.В. Чопик В.М. Михальський І.A. Шаповал С.Й. Поліщук GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM Технічна електродинаміка apparent power power factor minimization of power losses control strategy for shunt active filter reduced coordinate basis |
title | GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM |
title_full | GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM |
title_fullStr | GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM |
title_full_unstemmed | GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM |
title_short | GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM |
title_sort | generalized definition of the apparent power and energy efficient strategies of active filtration in the reduced coordinate base of a multiphase power supply system |
topic | apparent power power factor minimization of power losses control strategy for shunt active filter reduced coordinate basis |
url | https://techned.org.ua/index.php/techned/article/view/1602 |
work_keys_str_mv | AT mûartemenko generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem AT ûvkutafín generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem AT vvčopik generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem AT vmmihalʹsʹkij generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem AT íašapoval generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem AT sjpolíŝuk generalizeddefinitionoftheapparentpowerandenergyefficientstrategiesofactivefiltrationinthereducedcoordinatebaseofamultiphasepowersupplysystem |