Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile
Purpose. To compare the effects of correcting high myopia using the MEL®90 Triple-A profile LASEK at a 500 Hz pulse rate (Triple-A group) versus the Zyoptix tissue-saving ablations of Technolas 217z laser platform at 100 Hz (TS group). Methods. This retrospective study included 50 eyes in the Triple...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2019/6936042 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832552553464725504 |
---|---|
author | Min Li Yuehui Shi Lina Sun Lin Liu Chen Qu Jun Zou |
author_facet | Min Li Yuehui Shi Lina Sun Lin Liu Chen Qu Jun Zou |
author_sort | Min Li |
collection | DOAJ |
description | Purpose. To compare the effects of correcting high myopia using the MEL®90 Triple-A profile LASEK at a 500 Hz pulse rate (Triple-A group) versus the Zyoptix tissue-saving ablations of Technolas 217z laser platform at 100 Hz (TS group). Methods. This retrospective study included 50 eyes in the Triple-A group and 42 eyes in the TS group with manifest refraction spherical equivalent (MRSE) of −6 diopters (D) to −10 D. We compared uncorrected distance visual acuity, MRSE, corrected distance visual acuity, and postoperative complications at 1 month, 3 months, and 6 months. Results. At 6 months after refractive surgery, the efficacy index of Triple-A group was significantly higher than that of the TS group (1.03 ± 0.12 vs 1.00 ± 0.11, P=0.04). The MRSE postoperatively in the Triple-A group was significantly lower than that in the TS group (0.25 ± 0.18 vs 0.38 ± 0.23, P<0.01). The safety indices in the two groups were almost the same after 6 months of surgery (1.03 ± 0.07 vs 1.04 ± 0.11, P=0.63). The proportion of eyes which achieved ±0.13 D was significantly higher in the Triple-A group than that in the TS group at 1 month (80% vs 59.5%, P=0.03), 3 months (82% vs 61.9%, P=0.03) and 6 months (84% vs 64.3%, P=0.03). The changes in refraction 6 months after surgery comparing with 1 month after surgery were 0.12 ± 0.10 D in the Triple-A group and 0.13 ± 0.08 D in the TS group (P=0.56). All (100%) of the patients in the Triple-A group and 50% of the patients in the TS group had a UDVA of 20/16 at 6 months after surgery (P<0.01). The induced spherical aberrations and total HOAs in the Triple-A group were significantly lower than those in the TS group (0.17 ± 0.02 μm vs 0.23 ± 0.02 μm, P<0.01; 0.20 ± 0.04 μm vs 0.39 ± 0.03 μm, P<0.01) at 6 months after surgery. The mean reduced corneal thickness was 113.06 ± 10.5 μm in the Triple-A profile group and 121.43 ± 23.46 μm in the TS group (P=0.02). No patient in either group had haze and high intraocular pressure 6 months after surgery. Conclusion. For treatment of high-myopia patients, the Triple-A profile was more effective, predictable, and accurate than the Zyoptix tissue-saving profile. Meanwhile, the Triple-A profile had less induced spherical aberrations, total HOAs, and cornea ablation depth than the Zyoptix tissue-saving profile. Patients in the Triple-A group with 500 Hz pulse rate treatment achieved superior results. The two surgical procedures were equivalent in terms of safety and stability. |
format | Article |
id | doaj-art-282d996433064b5ca02272fe56f4ea13 |
institution | Kabale University |
issn | 2090-004X 2090-0058 |
language | English |
publishDate | 2019-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Ophthalmology |
spelling | doaj-art-282d996433064b5ca02272fe56f4ea132025-02-03T05:58:24ZengWileyJournal of Ophthalmology2090-004X2090-00582019-01-01201910.1155/2019/69360426936042Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving ProfileMin Li0Yuehui Shi1Lina Sun2Lin Liu3Chen Qu4Jun Zou5Department of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaDepartment of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaDepartment of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaDepartment of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaDepartment of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaDepartment of Ophthalmology, Shanghai Tenth People’s Hospital, No. 301 Middle Yanchang Road, Shanghai 200072, ChinaPurpose. To compare the effects of correcting high myopia using the MEL®90 Triple-A profile LASEK at a 500 Hz pulse rate (Triple-A group) versus the Zyoptix tissue-saving ablations of Technolas 217z laser platform at 100 Hz (TS group). Methods. This retrospective study included 50 eyes in the Triple-A group and 42 eyes in the TS group with manifest refraction spherical equivalent (MRSE) of −6 diopters (D) to −10 D. We compared uncorrected distance visual acuity, MRSE, corrected distance visual acuity, and postoperative complications at 1 month, 3 months, and 6 months. Results. At 6 months after refractive surgery, the efficacy index of Triple-A group was significantly higher than that of the TS group (1.03 ± 0.12 vs 1.00 ± 0.11, P=0.04). The MRSE postoperatively in the Triple-A group was significantly lower than that in the TS group (0.25 ± 0.18 vs 0.38 ± 0.23, P<0.01). The safety indices in the two groups were almost the same after 6 months of surgery (1.03 ± 0.07 vs 1.04 ± 0.11, P=0.63). The proportion of eyes which achieved ±0.13 D was significantly higher in the Triple-A group than that in the TS group at 1 month (80% vs 59.5%, P=0.03), 3 months (82% vs 61.9%, P=0.03) and 6 months (84% vs 64.3%, P=0.03). The changes in refraction 6 months after surgery comparing with 1 month after surgery were 0.12 ± 0.10 D in the Triple-A group and 0.13 ± 0.08 D in the TS group (P=0.56). All (100%) of the patients in the Triple-A group and 50% of the patients in the TS group had a UDVA of 20/16 at 6 months after surgery (P<0.01). The induced spherical aberrations and total HOAs in the Triple-A group were significantly lower than those in the TS group (0.17 ± 0.02 μm vs 0.23 ± 0.02 μm, P<0.01; 0.20 ± 0.04 μm vs 0.39 ± 0.03 μm, P<0.01) at 6 months after surgery. The mean reduced corneal thickness was 113.06 ± 10.5 μm in the Triple-A profile group and 121.43 ± 23.46 μm in the TS group (P=0.02). No patient in either group had haze and high intraocular pressure 6 months after surgery. Conclusion. For treatment of high-myopia patients, the Triple-A profile was more effective, predictable, and accurate than the Zyoptix tissue-saving profile. Meanwhile, the Triple-A profile had less induced spherical aberrations, total HOAs, and cornea ablation depth than the Zyoptix tissue-saving profile. Patients in the Triple-A group with 500 Hz pulse rate treatment achieved superior results. The two surgical procedures were equivalent in terms of safety and stability.http://dx.doi.org/10.1155/2019/6936042 |
spellingShingle | Min Li Yuehui Shi Lina Sun Lin Liu Chen Qu Jun Zou Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile Journal of Ophthalmology |
title | Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile |
title_full | Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile |
title_fullStr | Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile |
title_full_unstemmed | Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile |
title_short | Clinical Evaluation of LASEK for High Myopia Correction between the Triple-A Profile and the Zyoptix Tissue Saving Profile |
title_sort | clinical evaluation of lasek for high myopia correction between the triple a profile and the zyoptix tissue saving profile |
url | http://dx.doi.org/10.1155/2019/6936042 |
work_keys_str_mv | AT minli clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile AT yuehuishi clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile AT linasun clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile AT linliu clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile AT chenqu clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile AT junzou clinicalevaluationoflasekforhighmyopiacorrectionbetweenthetripleaprofileandthezyoptixtissuesavingprofile |