The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space

To improve oxygen generation performance, we dissected and analyzed the incompletely reacted oxygen candles and thus proposed the concept of the hollow-structured oxygen candle. We calculated the surface area ratio and designed the mold for hollow-structured oxygen candles at a radius of 0, 5, 9, 12...

Full description

Saved in:
Bibliographic Details
Main Authors: Weixiang Wang, Longzhe Jin, Na Gao, Jianlin Wang, Mingyang Liu
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2018/7469783
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832558299801714688
author Weixiang Wang
Longzhe Jin
Na Gao
Jianlin Wang
Mingyang Liu
author_facet Weixiang Wang
Longzhe Jin
Na Gao
Jianlin Wang
Mingyang Liu
author_sort Weixiang Wang
collection DOAJ
description To improve oxygen generation performance, we dissected and analyzed the incompletely reacted oxygen candles and thus proposed the concept of the hollow-structured oxygen candle. We calculated the surface area ratio and designed the mold for hollow-structured oxygen candles at a radius of 0, 5, 9, 12, 15.5, and 20 mm. The structural stability of the oxygen candles was tested by the loading experiment. The oxygen generation rate (OGR) and other properties were explored by combustion experiments. The composition of the oxygen candles and the residual solids after combustion were observed with scanning electron microscope (SEM). The results show that, with the increase of the hollow-structure radius (r), the stability of the hollow-structured oxygen candles gradually weakens, and the oxygen candles cannot be made when r is 20 mm. The hollow structure has a positive influence on the combustion of the oxygen candles, and the extent of combustion reaction can increase to 98.3% at the most, a 28.9% increase compared with that of solid-structured oxygen candles. The analysis of the morphology of cobalt(II,III) oxide and the macroscopic and microscopic morphology of the oxygen candles before and after combustion validates the rationality of the concept of the hollow-structured oxygen candle. The best performance of the oxygen candles is obtained when r = 9 mm, where the highest extent of combustion reaction is 98.3%. The total oxygen generated is 48.75 L, and the average rate is 9.2 L/min. The test of the oxygen candles with r = 9 mm after combustion by the X-ray diffractometer (XRD) shows that these oxygen candles fully reacted. This study provides a basis for optimizing the performance of oxygen candles and for the development of the oxygen supply system fitted with the oxygen candle in spaceflight, submarine, and underground space.
format Article
id doaj-art-266e741a1dbe44fc8d9229a9f6caad7b
institution Kabale University
issn 2090-9063
2090-9071
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Journal of Chemistry
spelling doaj-art-266e741a1dbe44fc8d9229a9f6caad7b2025-02-03T01:32:38ZengWileyJournal of Chemistry2090-90632090-90712018-01-01201810.1155/2018/74697837469783The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge SpaceWeixiang Wang0Longzhe Jin1Na Gao2Jianlin Wang3Mingyang Liu4School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, ChinaSchool of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, ChinaSchool of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, ChinaSchool of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, ChinaSchool of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, ChinaTo improve oxygen generation performance, we dissected and analyzed the incompletely reacted oxygen candles and thus proposed the concept of the hollow-structured oxygen candle. We calculated the surface area ratio and designed the mold for hollow-structured oxygen candles at a radius of 0, 5, 9, 12, 15.5, and 20 mm. The structural stability of the oxygen candles was tested by the loading experiment. The oxygen generation rate (OGR) and other properties were explored by combustion experiments. The composition of the oxygen candles and the residual solids after combustion were observed with scanning electron microscope (SEM). The results show that, with the increase of the hollow-structure radius (r), the stability of the hollow-structured oxygen candles gradually weakens, and the oxygen candles cannot be made when r is 20 mm. The hollow structure has a positive influence on the combustion of the oxygen candles, and the extent of combustion reaction can increase to 98.3% at the most, a 28.9% increase compared with that of solid-structured oxygen candles. The analysis of the morphology of cobalt(II,III) oxide and the macroscopic and microscopic morphology of the oxygen candles before and after combustion validates the rationality of the concept of the hollow-structured oxygen candle. The best performance of the oxygen candles is obtained when r = 9 mm, where the highest extent of combustion reaction is 98.3%. The total oxygen generated is 48.75 L, and the average rate is 9.2 L/min. The test of the oxygen candles with r = 9 mm after combustion by the X-ray diffractometer (XRD) shows that these oxygen candles fully reacted. This study provides a basis for optimizing the performance of oxygen candles and for the development of the oxygen supply system fitted with the oxygen candle in spaceflight, submarine, and underground space.http://dx.doi.org/10.1155/2018/7469783
spellingShingle Weixiang Wang
Longzhe Jin
Na Gao
Jianlin Wang
Mingyang Liu
The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
Journal of Chemistry
title The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
title_full The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
title_fullStr The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
title_full_unstemmed The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
title_short The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space
title_sort oxygen generation performance of hollow structured oxygen candle for refuge space
url http://dx.doi.org/10.1155/2018/7469783
work_keys_str_mv AT weixiangwang theoxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT longzhejin theoxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT nagao theoxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT jianlinwang theoxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT mingyangliu theoxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT weixiangwang oxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT longzhejin oxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT nagao oxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT jianlinwang oxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace
AT mingyangliu oxygengenerationperformanceofhollowstructuredoxygencandleforrefugespace