STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY

The paper presents results of the ВНК-21/2-17 lineage cell cycle tests using flow cytometry. This cell line is widely used in biological industry that is why studying the ВНК-21/2-17 cell suspension pattern using the proposed technique and determination of tools and methods to prevent morphological...

Full description

Saved in:
Bibliographic Details
Main Authors: M. A. Shevchenko, M. N. Guseva, D. V. Mikhalishin, B. L. Manin, A. A. Shishkova
Format: Article
Language:English
Published: Da Vinci Media 2018-04-01
Series:Ветеринария сегодня
Subjects:
Online Access:https://veterinary.arriah.ru/jour/article/view/334
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832086822204735488
author M. A. Shevchenko
M. N. Guseva
D. V. Mikhalishin
B. L. Manin
A. A. Shishkova
author_facet M. A. Shevchenko
M. N. Guseva
D. V. Mikhalishin
B. L. Manin
A. A. Shishkova
author_sort M. A. Shevchenko
collection DOAJ
description The paper presents results of the ВНК-21/2-17 lineage cell cycle tests using flow cytometry. This cell line is widely used in biological industry that is why studying the ВНК-21/2-17 cell suspension pattern using the proposed technique and determination of tools and methods to prevent morphological and structural cell modifications in the culture affected by negative factors is of great interest. Flow cytometry allows to determine quantitative parameters of cell cycle phases and perform correlation between these phases and viability of the working cell population. It was mentioned that the general trend of this cell lineage suspension cultivation for 48 hours has a standard dynamics, herewith at all stages of the cell cycle the primary growth stage - G1 prevailed. Under unfavorable conditions of cultivation apoptotic debris could increase up to 31-59%, i. e. part of the cell population could be potentially non-reproductive. Unsuccessful cultivation stages associated with low pH content in the cultivator where pH was not maintained at the constant level were detected. During optimization of cell cultivation physical and chemical parameters proliferation intensity increased. Viable cell yield during cultivation when a specific pH was maintained was higher and at the synthetic stage G2 + M no cycle delay occurred.
format Article
id doaj-art-22457c660c854b5bb028cc1328ef3f04
institution Kabale University
issn 2304-196X
2658-6959
language English
publishDate 2018-04-01
publisher Da Vinci Media
record_format Article
series Ветеринария сегодня
spelling doaj-art-22457c660c854b5bb028cc1328ef3f042025-02-06T09:52:06ZengDa Vinci MediaВетеринария сегодня2304-196X2658-69592018-04-01045862334STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRYM. A. Shevchenko0M. N. Guseva1D. V. Mikhalishin2B. L. Manin3A. A. Shishkova4FGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirThe paper presents results of the ВНК-21/2-17 lineage cell cycle tests using flow cytometry. This cell line is widely used in biological industry that is why studying the ВНК-21/2-17 cell suspension pattern using the proposed technique and determination of tools and methods to prevent morphological and structural cell modifications in the culture affected by negative factors is of great interest. Flow cytometry allows to determine quantitative parameters of cell cycle phases and perform correlation between these phases and viability of the working cell population. It was mentioned that the general trend of this cell lineage suspension cultivation for 48 hours has a standard dynamics, herewith at all stages of the cell cycle the primary growth stage - G1 prevailed. Under unfavorable conditions of cultivation apoptotic debris could increase up to 31-59%, i. e. part of the cell population could be potentially non-reproductive. Unsuccessful cultivation stages associated with low pH content in the cultivator where pH was not maintained at the constant level were detected. During optimization of cell cultivation physical and chemical parameters proliferation intensity increased. Viable cell yield during cultivation when a specific pH was maintained was higher and at the synthetic stage G2 + M no cycle delay occurred.https://veterinary.arriah.ru/jour/article/view/334проточная цитометрияапоптозфазы клеточного циклаflow cytometryapoptosiscell cycle phases
spellingShingle M. A. Shevchenko
M. N. Guseva
D. V. Mikhalishin
B. L. Manin
A. A. Shishkova
STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
Ветеринария сегодня
проточная цитометрия
апоптоз
фазы клеточного цикла
flow cytometry
apoptosis
cell cycle phases
title STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
title_full STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
title_fullStr STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
title_full_unstemmed STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
title_short STUDIES OF THE BHK-21/2-17 LINEAGE USING FLOW CYTOMETRY
title_sort studies of the bhk 21 2 17 lineage using flow cytometry
topic проточная цитометрия
апоптоз
фазы клеточного цикла
flow cytometry
apoptosis
cell cycle phases
url https://veterinary.arriah.ru/jour/article/view/334
work_keys_str_mv AT mashevchenko studiesofthebhk21217lineageusingflowcytometry
AT mnguseva studiesofthebhk21217lineageusingflowcytometry
AT dvmikhalishin studiesofthebhk21217lineageusingflowcytometry
AT blmanin studiesofthebhk21217lineageusingflowcytometry
AT aashishkova studiesofthebhk21217lineageusingflowcytometry