Time Domain Response of Uniform RC Lines with RC Termination at Both Ends
The time domain response of uniform RC lines with RC termination at both ends is obtained from the approximate poles of the transfer function. A simple model is developed for the URC line. The model consists of three passive elements only and can be easily implemented for computer-aided analysis of...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
1997-01-01
|
Series: | Active and Passive Electronic Components |
Online Access: | http://dx.doi.org/10.1155/1997/84383 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832551515686961152 |
---|---|
author | Muhammad Taher Abuelma'atti |
author_facet | Muhammad Taher Abuelma'atti |
author_sort | Muhammad Taher Abuelma'atti |
collection | DOAJ |
description | The time domain response of uniform RC lines with RC termination at both ends is obtained from the
approximate poles of the transfer function. A simple model is developed for the URC line. The model
consists of three passive elements only and can be easily implemented for computer-aided analysis of
URC lines with RC termination at both ends. |
format | Article |
id | doaj-art-21cb30ec381f45c492cc1e9e68356fad |
institution | Kabale University |
issn | 0882-7516 1563-5031 |
language | English |
publishDate | 1997-01-01 |
publisher | Wiley |
record_format | Article |
series | Active and Passive Electronic Components |
spelling | doaj-art-21cb30ec381f45c492cc1e9e68356fad2025-02-03T06:01:15ZengWileyActive and Passive Electronic Components0882-75161563-50311997-01-0119419920310.1155/1997/84383Time Domain Response of Uniform RC Lines with RC Termination at Both EndsMuhammad Taher Abuelma'atti0King Fahd University of Petroleum and Minerals, Box 203, Dhahran 31261, Saudi ArabiaThe time domain response of uniform RC lines with RC termination at both ends is obtained from the approximate poles of the transfer function. A simple model is developed for the URC line. The model consists of three passive elements only and can be easily implemented for computer-aided analysis of URC lines with RC termination at both ends.http://dx.doi.org/10.1155/1997/84383 |
spellingShingle | Muhammad Taher Abuelma'atti Time Domain Response of Uniform RC Lines with RC Termination at Both Ends Active and Passive Electronic Components |
title | Time Domain Response of Uniform RC Lines with RC Termination at Both Ends |
title_full | Time Domain Response of Uniform RC Lines with RC Termination at Both Ends |
title_fullStr | Time Domain Response of Uniform RC Lines with RC Termination at Both Ends |
title_full_unstemmed | Time Domain Response of Uniform RC Lines with RC Termination at Both Ends |
title_short | Time Domain Response of Uniform RC Lines with RC Termination at Both Ends |
title_sort | time domain response of uniform rc lines with rc termination at both ends |
url | http://dx.doi.org/10.1155/1997/84383 |
work_keys_str_mv | AT muhammadtaherabuelmaatti timedomainresponseofuniformrclineswithrcterminationatbothends |