Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye

The study of the effects on the microvasculature of various vasoactive drugs requires appro-priate methods and equipment for determining the basic physiological parameters of small blood vessels: their internal diameter and cross-sectional area, specific density, and blood flow velocity. Therefore,...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Firago, A. I. Kubarko
Format: Article
Language:English
Published: Belarusian National Technical University 2019-06-01
Series:Приборы и методы измерений
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/442
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543757894942720
author V. A. Firago
A. I. Kubarko
author_facet V. A. Firago
A. I. Kubarko
author_sort V. A. Firago
collection DOAJ
description The study of the effects on the microvasculature of various vasoactive drugs requires appro-priate methods and equipment for determining the basic physiological parameters of small blood vessels: their internal diameter and cross-sectional area, specific density, and blood flow velocity. Therefore, the purpose of the article is to study the possibilities of improving the reliability of determining the internal diameter and cross-sectional area of the visible blood vessels of bulbar con-junctival of the eye.A technique for obtaining digital video recordings of the bulbar conjunctiva of the eye, based on the pulse illumination of the study area, is proposed. A prototype of the equipment with a spatial resolution of 2 µm video is described, which allows to trace all visible blood vessels, including capillaries. An algorithm for stabilizing the position of a sequence of digital images of the bulbar conjunctiva relative to the first frame is discussed. It is based on the use of subpixel interpolation when searching for a global minimum of the standard deviation of the differences in brightness of the first and selected frame.The proposed algorithms for tracing the vascular pattern and determining the internal diameter and cross-sectional area of the blood vessels are described. An original method for calculating them is proposed, which is based on determining the area and height of a cross section of a blood vessel image. The problem of verification of the obtained results is discussed.The described approach to make it possible to create diagnostic images of the visible blood vessels of the bulbar conjunctiva, including the capillaries, with an indication of their diameters. Examples of the construction of histograms of the distribution of the internal diameter and cross-sectional area of these blood vessels are presented.The proposed technique and hardware solutions have the prospect of being used in creating equipment for complex non-invasive diagnostics of the microvasculature and monitoring the effectiveness of treating various diseases of the cardiovascular system, since the conditions of the eye blood vessels correlate with the state of the blood vessels in other organs.
format Article
id doaj-art-202da1993b424f839127d9ec5020d967
institution Kabale University
issn 2220-9506
2414-0473
language English
publishDate 2019-06-01
publisher Belarusian National Technical University
record_format Article
series Приборы и методы измерений
spelling doaj-art-202da1993b424f839127d9ec5020d9672025-02-03T11:28:27ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732019-06-0110218519710.21122/2220-9506-2019-10-2-185-197352Technique for Measuring the Internal Diameter and Area of Visible Vessels of the EyeV. A. Firago0A. I. Kubarko1Belarusian State UniversityBelarusian State Medical UniversityThe study of the effects on the microvasculature of various vasoactive drugs requires appro-priate methods and equipment for determining the basic physiological parameters of small blood vessels: their internal diameter and cross-sectional area, specific density, and blood flow velocity. Therefore, the purpose of the article is to study the possibilities of improving the reliability of determining the internal diameter and cross-sectional area of the visible blood vessels of bulbar con-junctival of the eye.A technique for obtaining digital video recordings of the bulbar conjunctiva of the eye, based on the pulse illumination of the study area, is proposed. A prototype of the equipment with a spatial resolution of 2 µm video is described, which allows to trace all visible blood vessels, including capillaries. An algorithm for stabilizing the position of a sequence of digital images of the bulbar conjunctiva relative to the first frame is discussed. It is based on the use of subpixel interpolation when searching for a global minimum of the standard deviation of the differences in brightness of the first and selected frame.The proposed algorithms for tracing the vascular pattern and determining the internal diameter and cross-sectional area of the blood vessels are described. An original method for calculating them is proposed, which is based on determining the area and height of a cross section of a blood vessel image. The problem of verification of the obtained results is discussed.The described approach to make it possible to create diagnostic images of the visible blood vessels of the bulbar conjunctiva, including the capillaries, with an indication of their diameters. Examples of the construction of histograms of the distribution of the internal diameter and cross-sectional area of these blood vessels are presented.The proposed technique and hardware solutions have the prospect of being used in creating equipment for complex non-invasive diagnostics of the microvasculature and monitoring the effectiveness of treating various diseases of the cardiovascular system, since the conditions of the eye blood vessels correlate with the state of the blood vessels in other organs.https://pimi.bntu.by/jour/article/view/442microcirculatory bedmeasurement of small vessel sizesinternal diameter and area of vesselsdigital microscopydigital image processing algorithms
spellingShingle V. A. Firago
A. I. Kubarko
Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
Приборы и методы измерений
microcirculatory bed
measurement of small vessel sizes
internal diameter and area of vessels
digital microscopy
digital image processing algorithms
title Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
title_full Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
title_fullStr Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
title_full_unstemmed Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
title_short Technique for Measuring the Internal Diameter and Area of Visible Vessels of the Eye
title_sort technique for measuring the internal diameter and area of visible vessels of the eye
topic microcirculatory bed
measurement of small vessel sizes
internal diameter and area of vessels
digital microscopy
digital image processing algorithms
url https://pimi.bntu.by/jour/article/view/442
work_keys_str_mv AT vafirago techniqueformeasuringtheinternaldiameterandareaofvisiblevesselsoftheeye
AT aikubarko techniqueformeasuringtheinternaldiameterandareaofvisiblevesselsoftheeye