A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit
Abstract A novel 40‐pulse autotransformer rectifier is proposed to reduce total harmonic distortion (THD) of the input current in aircraft electrical power systems. The 40‐pulse rectifier (40PR) includes a passive harmonic reduction circuit (PHMC) with a low kVA rating (about 0.95% of the load power...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-12-01
|
Series: | IET Electrical Systems in Transportation |
Subjects: | |
Online Access: | https://doi.org/10.1049/els2.12057 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832559538923896832 |
---|---|
author | Rohollah Abdollahi Gevork B. Gharehpetian |
author_facet | Rohollah Abdollahi Gevork B. Gharehpetian |
author_sort | Rohollah Abdollahi |
collection | DOAJ |
description | Abstract A novel 40‐pulse autotransformer rectifier is proposed to reduce total harmonic distortion (THD) of the input current in aircraft electrical power systems. The 40‐pulse rectifier (40PR) includes a passive harmonic reduction circuit (PHMC) with a low kVA rating (about 0.95% of the load power) to enhance the performance of the conventional 40PR. This PHMC is based on 2 harmonic suppression circuits and contains four tapped reactor and 4 auxiliary diodes. 50 Hz simulations of the improved 40PR indicate that THD of the input current and voltage is less than 2%, which meets the IEEE‐519 standard. In addition, without using any input and output filters, input current harmonic components at 400–800 Hz are less than the requirements mentioned in the DO‐160G and MIL‐STD‐704F standards. The suggested PHMC can easily be implemented. A prototype is developed to verify the proposed design. A good agreement can be seen in simulation and experimental results. |
format | Article |
id | doaj-art-1f6340af2f4d47aebcb4f383b7531722 |
institution | Kabale University |
issn | 2042-9738 2042-9746 |
language | English |
publishDate | 2022-12-01 |
publisher | Wiley |
record_format | Article |
series | IET Electrical Systems in Transportation |
spelling | doaj-art-1f6340af2f4d47aebcb4f383b75317222025-02-03T01:29:44ZengWileyIET Electrical Systems in Transportation2042-97382042-97462022-12-0112433034310.1049/els2.12057A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuitRohollah Abdollahi0Gevork B. Gharehpetian1Electrical Engineering Department Technical and Vocational University Tehran IranElectrical Engineering Department Amirkabir University of Technology Tehran IranAbstract A novel 40‐pulse autotransformer rectifier is proposed to reduce total harmonic distortion (THD) of the input current in aircraft electrical power systems. The 40‐pulse rectifier (40PR) includes a passive harmonic reduction circuit (PHMC) with a low kVA rating (about 0.95% of the load power) to enhance the performance of the conventional 40PR. This PHMC is based on 2 harmonic suppression circuits and contains four tapped reactor and 4 auxiliary diodes. 50 Hz simulations of the improved 40PR indicate that THD of the input current and voltage is less than 2%, which meets the IEEE‐519 standard. In addition, without using any input and output filters, input current harmonic components at 400–800 Hz are less than the requirements mentioned in the DO‐160G and MIL‐STD‐704F standards. The suggested PHMC can easily be implemented. A prototype is developed to verify the proposed design. A good agreement can be seen in simulation and experimental results.https://doi.org/10.1049/els2.12057low‐rating rectifiersmulti‐pulse rectifierpassive harmonic suppressionpower qualitytapped reactors |
spellingShingle | Rohollah Abdollahi Gevork B. Gharehpetian A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit IET Electrical Systems in Transportation low‐rating rectifiers multi‐pulse rectifier passive harmonic suppression power quality tapped reactors |
title | A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit |
title_full | A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit |
title_fullStr | A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit |
title_full_unstemmed | A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit |
title_short | A low‐rating 40‐pulse AC–DC rectifier based on a new passive harmonic mitigation circuit |
title_sort | low rating 40 pulse ac dc rectifier based on a new passive harmonic mitigation circuit |
topic | low‐rating rectifiers multi‐pulse rectifier passive harmonic suppression power quality tapped reactors |
url | https://doi.org/10.1049/els2.12057 |
work_keys_str_mv | AT rohollahabdollahi alowrating40pulseacdcrectifierbasedonanewpassiveharmonicmitigationcircuit AT gevorkbgharehpetian alowrating40pulseacdcrectifierbasedonanewpassiveharmonicmitigationcircuit AT rohollahabdollahi lowrating40pulseacdcrectifierbasedonanewpassiveharmonicmitigationcircuit AT gevorkbgharehpetian lowrating40pulseacdcrectifierbasedonanewpassiveharmonicmitigationcircuit |