Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network

The development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the eff...

Full description

Saved in:
Bibliographic Details
Main Authors: Yan Li, Jianyuan Xu, Peng Wang, Guanhua Li
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/2/256
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832588534874112000
author Yan Li
Jianyuan Xu
Peng Wang
Guanhua Li
author_facet Yan Li
Jianyuan Xu
Peng Wang
Guanhua Li
author_sort Yan Li
collection DOAJ
description The development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the effects of grounding current, arc length, environmental wind speed, and other variables on the characteristics of the arc. In response to this issue, this article establishes a three-dimensional single-phase grounding arc mathematical model grounded in magnetohydrodynamics. It simulates and analyzes the effects of arc length and environmental wind speed on both arc ignition and extinguishing. Furthermore, an artificial single-phase grounding test platform is constructed within the actual distribution network to validate the accuracy of the simulation model. Research has demonstrated that, under identical operating conditions for both simulation and experimentation, the error range between the simulated arc voltage and the measured data is within 8%. The three-dimensional single-phase grounding arc mathematical model effectively describes the dynamic development process of the grounding arc. At a gap of 12 cm, under windless conditions and with a grounding current of 40.0 A, the temperature of the arc column at the peak of the current reaches 2600 K, while the conductivity decreases to 2.1 × 10<sup>−4</sup> S/m, resulting in the inability of the arc to sustain a burning state. At a gap of 2 cm and a wind speed of 7 m/s, the temperature of the arc column at the peak of the current reaches 2900 K, the conductivity drops to 4.3 × 10<sup>−3</sup> S/m, leading to the extinction of the arc.
format Article
id doaj-art-1f4745b64d7d4c648b83a98846889102
institution Kabale University
issn 1996-1073
language English
publishDate 2025-01-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-1f4745b64d7d4c648b83a988468891022025-01-24T13:30:48ZengMDPI AGEnergies1996-10732025-01-0118225610.3390/en18020256Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution NetworkYan Li0Jianyuan Xu1Peng Wang2Guanhua Li3School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, ChinaSchool of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, ChinaState Grid Liaoning Electric Power Co., Ltd., Shenyang 110004, ChinaState Grid Liaoning Electric Power Co., Ltd., Electric Power Science Research Institute, Shenyang 110055, ChinaThe development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the effects of grounding current, arc length, environmental wind speed, and other variables on the characteristics of the arc. In response to this issue, this article establishes a three-dimensional single-phase grounding arc mathematical model grounded in magnetohydrodynamics. It simulates and analyzes the effects of arc length and environmental wind speed on both arc ignition and extinguishing. Furthermore, an artificial single-phase grounding test platform is constructed within the actual distribution network to validate the accuracy of the simulation model. Research has demonstrated that, under identical operating conditions for both simulation and experimentation, the error range between the simulated arc voltage and the measured data is within 8%. The three-dimensional single-phase grounding arc mathematical model effectively describes the dynamic development process of the grounding arc. At a gap of 12 cm, under windless conditions and with a grounding current of 40.0 A, the temperature of the arc column at the peak of the current reaches 2600 K, while the conductivity decreases to 2.1 × 10<sup>−4</sup> S/m, resulting in the inability of the arc to sustain a burning state. At a gap of 2 cm and a wind speed of 7 m/s, the temperature of the arc column at the peak of the current reaches 2900 K, the conductivity drops to 4.3 × 10<sup>−3</sup> S/m, leading to the extinction of the arc.https://www.mdpi.com/1996-1073/18/2/256grounding arcwind speedmagnetohydrodynamicsartificial single-phase grounding test platformtemperature of the arc column
spellingShingle Yan Li
Jianyuan Xu
Peng Wang
Guanhua Li
Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
Energies
grounding arc
wind speed
magnetohydrodynamics
artificial single-phase grounding test platform
temperature of the arc column
title Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
title_full Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
title_fullStr Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
title_full_unstemmed Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
title_short Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
title_sort research on arc extinguishing characteristics of single phase grounding fault in distribution network
topic grounding arc
wind speed
magnetohydrodynamics
artificial single-phase grounding test platform
temperature of the arc column
url https://www.mdpi.com/1996-1073/18/2/256
work_keys_str_mv AT yanli researchonarcextinguishingcharacteristicsofsinglephasegroundingfaultindistributionnetwork
AT jianyuanxu researchonarcextinguishingcharacteristicsofsinglephasegroundingfaultindistributionnetwork
AT pengwang researchonarcextinguishingcharacteristicsofsinglephasegroundingfaultindistributionnetwork
AT guanhuali researchonarcextinguishingcharacteristicsofsinglephasegroundingfaultindistributionnetwork