DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES
Background: Time Repetition (TR) is one of the main parameters of Inversion Recovery. The purpose of this study to determine differences in anatomical MRI information on the variation of the knee joint TR sequences STIR Sagittal slices. Method: Type of research is experimental. The study was conduct...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Airlangga
2020-11-01
|
Series: | Journal of Vocational Health Studies |
Subjects: | |
Online Access: | https://e-journal.unair.ac.id/JVHS/article/view/22575 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832572324805607424 |
---|---|
author | Rini Indrati Lydia Purna Widyastuti Tri Puspita Sari Sudiyono Sudiyono |
author_facet | Rini Indrati Lydia Purna Widyastuti Tri Puspita Sari Sudiyono Sudiyono |
author_sort | Rini Indrati |
collection | DOAJ |
description | Background: Time Repetition (TR) is one of the main parameters of Inversion Recovery. The purpose of this study to determine differences in anatomical MRI information on the variation of the knee joint TR sequences STIR Sagittal slices. Method: Type of research is experimental. The study was conducted with MRI 1.5 Tesla. Data in the form of 42 image sequences STIR MRI knee joint with TR 3500, 4000, 4500, 5000, 5500, 6000, and 6500 ms. Anatomical assessments on the anterior cruciate ligament, posterior cruciate ligament, articular cartilage, and meniscus were performed by a radiologist. Data analyzed by Friedman and Wilcoxon test. Result: The results showed that there were differences in the MRI anatomical information of the knee joint of the STIR sagitas slice in the TR variation with p-value < 0.001. There is a difference in anatomical information between TR 5000 and 6000 ms (p-value = 0.034), TR 5000 and 6500 ms (p-value = 0.024), TR 5500 and 6500 ms (p-value = 0.038). There is no difference in anatomical information between TR 4500 and 5000 ms (p-value = 0.395), TR 4500 and 5500 ms (p-value = 0.131), TR 4500 and 6000 ms (p-value = 0.078), TR 4500 and 6500 ms (p-value = 0.066), TR 5000 and 5500 ms (p-value = 0.414), TR 5500 and 6000 ms (p-value = 0.102), TR 6000 and 6500 ms (p-value = 0.083). Conclusion: The optimal value to produce anatomical information of the knee joint sagittal MRI sequences STIR is TR 4500 ms. |
format | Article |
id | doaj-art-1eaa94f80306452a926315943647aa75 |
institution | Kabale University |
issn | 2580-7161 2580-717X |
language | English |
publishDate | 2020-11-01 |
publisher | Universitas Airlangga |
record_format | Article |
series | Journal of Vocational Health Studies |
spelling | doaj-art-1eaa94f80306452a926315943647aa752025-02-02T10:33:31ZengUniversitas AirlanggaJournal of Vocational Health Studies2580-71612580-717X2020-11-0142899410.20473/jvhs.V4.I2.2020.89-9411211DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICESRini Indrati0Lydia Purna Widyastuti1Tri Puspita Sari2Sudiyono Sudiyono3Department of Radiodiagnostic and Radioteraphy, Health Polytechnic of Semarang. Semarang-IndonesiaFaculty of Medicine, Universitas Diponegoro, Semarang - IndonesiaRadiodiagnostic Department, Haji General Hospital, Surabaya - IndonesiaDepartment of Radiodiagnostic and Radioteraphy, Health Polytechnic of Semarang. Semarang - IndonesiaBackground: Time Repetition (TR) is one of the main parameters of Inversion Recovery. The purpose of this study to determine differences in anatomical MRI information on the variation of the knee joint TR sequences STIR Sagittal slices. Method: Type of research is experimental. The study was conducted with MRI 1.5 Tesla. Data in the form of 42 image sequences STIR MRI knee joint with TR 3500, 4000, 4500, 5000, 5500, 6000, and 6500 ms. Anatomical assessments on the anterior cruciate ligament, posterior cruciate ligament, articular cartilage, and meniscus were performed by a radiologist. Data analyzed by Friedman and Wilcoxon test. Result: The results showed that there were differences in the MRI anatomical information of the knee joint of the STIR sagitas slice in the TR variation with p-value < 0.001. There is a difference in anatomical information between TR 5000 and 6000 ms (p-value = 0.034), TR 5000 and 6500 ms (p-value = 0.024), TR 5500 and 6500 ms (p-value = 0.038). There is no difference in anatomical information between TR 4500 and 5000 ms (p-value = 0.395), TR 4500 and 5500 ms (p-value = 0.131), TR 4500 and 6000 ms (p-value = 0.078), TR 4500 and 6500 ms (p-value = 0.066), TR 5000 and 5500 ms (p-value = 0.414), TR 5500 and 6000 ms (p-value = 0.102), TR 6000 and 6500 ms (p-value = 0.083). Conclusion: The optimal value to produce anatomical information of the knee joint sagittal MRI sequences STIR is TR 4500 ms.https://e-journal.unair.ac.id/JVHS/article/view/22575time repetitionknee jointmristir |
spellingShingle | Rini Indrati Lydia Purna Widyastuti Tri Puspita Sari Sudiyono Sudiyono DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES Journal of Vocational Health Studies time repetition knee joint mri stir |
title | DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES |
title_full | DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES |
title_fullStr | DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES |
title_full_unstemmed | DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES |
title_short | DIFFERENCE OF ANATOMY INFORMATION MRI KNEE JOINT ON VARIATION OF TIME REPETITION SEQUENCES STIR IN SAGITTAL SLICES |
title_sort | difference of anatomy information mri knee joint on variation of time repetition sequences stir in sagittal slices |
topic | time repetition knee joint mri stir |
url | https://e-journal.unair.ac.id/JVHS/article/view/22575 |
work_keys_str_mv | AT riniindrati differenceofanatomyinformationmrikneejointonvariationoftimerepetitionsequencesstirinsagittalslices AT lydiapurnawidyastuti differenceofanatomyinformationmrikneejointonvariationoftimerepetitionsequencesstirinsagittalslices AT tripuspitasari differenceofanatomyinformationmrikneejointonvariationoftimerepetitionsequencesstirinsagittalslices AT sudiyonosudiyono differenceofanatomyinformationmrikneejointonvariationoftimerepetitionsequencesstirinsagittalslices |