Features of Surgical Correction of Spontaneous Luxation of the Complex “IOL Posterior Chamber – Capsular Bag”
Luxation of intraocular lens in capsular bag several years after cataract surgery leads to a decrease in visual function and requires surgical treatment.Aim: to determine effectiveness of various types of surgical treatment of late spontaneous dislocations of IOL in capsular bag.Methods. Analysis of...