Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels

The traditional health indicator (HI) construction method of electric equipment devices in microgrid networks, such as bearings that require different time-frequency domain indicators, needs several models to combine. Therefore, it is necessary to manually select appropriate and sensitive models, su...

Full description

Saved in:
Bibliographic Details
Main Authors: Fan Xu, Xin Shu, Xin Li, Xiaodi Zhang
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Complexity
Online Access:http://dx.doi.org/10.1155/2020/5013871
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550817208467456
author Fan Xu
Xin Shu
Xin Li
Xiaodi Zhang
author_facet Fan Xu
Xin Shu
Xin Li
Xiaodi Zhang
author_sort Fan Xu
collection DOAJ
description The traditional health indicator (HI) construction method of electric equipment devices in microgrid networks, such as bearings that require different time-frequency domain indicators, needs several models to combine. Therefore, it is necessary to manually select appropriate and sensitive models, such as time-frequency domain indicators and multimodel fusion, to build HIs in multiple steps, which is more complicated because sensitivity characteristics and suitable models are more representatives of bearing degradation trends. In this paper, we use the stacked denoising autoencoder (SDAE) model in deep learning to construct HI directly from the microgrid power equipment of raw signals in bearings. With this model, the HI can be constructed without multiple model combinations or the need for manual experience in selecting the sensitive indicators. The SDAE can extract the representative degradation information adaptively from the original data through several nonlinear hidden layers automatically and approximate complicated nonlinear functions with a small reconstruction error. After the SDAE extracts the preliminary HI, a model is needed to divide the wear state of the HI constructed by the SDAE. A cluster model is commonly used for this, and unlike most clustering methods such as k-means, k-medoids, and fuzzy c-means (FCM), in which the clustering center point must be preset, cluster by fast search (CFS) can automatically find available cluster center points automatically according to the distance and local density between each point and its clustering center point. Thus, the selected cluster center points are used to divide the wear state of the bearing. The root mean square (RMS), kurtosis, Shannon entropy (SHE), approximate entropy (AE), permutation entropy (PE), and principal component analysis (PCA) are also used to construct the HI. Finally, the results show that the performance of the method (SDAE-CFS) presented is superior to other combination HI models, such as EEMD-SVD-FCM/k-means/k-medoids, stacked autoencoder-CFS (SAE-CFS), RMS, kurtosis, SHE, AE, PE, and PCA.
format Article
id doaj-art-1c1a5d35d5484f8ea5ad2f4a76ec2885
institution Kabale University
issn 1076-2787
1099-0526
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Complexity
spelling doaj-art-1c1a5d35d5484f8ea5ad2f4a76ec28852025-02-03T06:05:40ZengWileyComplexity1076-27871099-05262020-01-01202010.1155/2020/50138715013871Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data LabelsFan Xu0Xin Shu1Xin Li2Xiaodi Zhang3School of Automation, China University of Geosciences, Wuhan 730072, ChinaChina Railway Major Bridge Engineering Group Co., Ltd., Wuhan 730072, ChinaSchool of Energy and Power Engineering, Wuhan University of Technology, Wuhan 730072, ChinaState Grid Beijing Electric Power Company, Beijing 100080, ChinaThe traditional health indicator (HI) construction method of electric equipment devices in microgrid networks, such as bearings that require different time-frequency domain indicators, needs several models to combine. Therefore, it is necessary to manually select appropriate and sensitive models, such as time-frequency domain indicators and multimodel fusion, to build HIs in multiple steps, which is more complicated because sensitivity characteristics and suitable models are more representatives of bearing degradation trends. In this paper, we use the stacked denoising autoencoder (SDAE) model in deep learning to construct HI directly from the microgrid power equipment of raw signals in bearings. With this model, the HI can be constructed without multiple model combinations or the need for manual experience in selecting the sensitive indicators. The SDAE can extract the representative degradation information adaptively from the original data through several nonlinear hidden layers automatically and approximate complicated nonlinear functions with a small reconstruction error. After the SDAE extracts the preliminary HI, a model is needed to divide the wear state of the HI constructed by the SDAE. A cluster model is commonly used for this, and unlike most clustering methods such as k-means, k-medoids, and fuzzy c-means (FCM), in which the clustering center point must be preset, cluster by fast search (CFS) can automatically find available cluster center points automatically according to the distance and local density between each point and its clustering center point. Thus, the selected cluster center points are used to divide the wear state of the bearing. The root mean square (RMS), kurtosis, Shannon entropy (SHE), approximate entropy (AE), permutation entropy (PE), and principal component analysis (PCA) are also used to construct the HI. Finally, the results show that the performance of the method (SDAE-CFS) presented is superior to other combination HI models, such as EEMD-SVD-FCM/k-means/k-medoids, stacked autoencoder-CFS (SAE-CFS), RMS, kurtosis, SHE, AE, PE, and PCA.http://dx.doi.org/10.1155/2020/5013871
spellingShingle Fan Xu
Xin Shu
Xin Li
Xiaodi Zhang
Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
Complexity
title Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
title_full Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
title_fullStr Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
title_full_unstemmed Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
title_short Data-Driven Bearing Fault Diagnosis of Microgrid Network Power Device Based on a Stacked Denoising Autoencoder in Deep Learning and Clustering by Fast Search without Data Labels
title_sort data driven bearing fault diagnosis of microgrid network power device based on a stacked denoising autoencoder in deep learning and clustering by fast search without data labels
url http://dx.doi.org/10.1155/2020/5013871
work_keys_str_mv AT fanxu datadrivenbearingfaultdiagnosisofmicrogridnetworkpowerdevicebasedonastackeddenoisingautoencoderindeeplearningandclusteringbyfastsearchwithoutdatalabels
AT xinshu datadrivenbearingfaultdiagnosisofmicrogridnetworkpowerdevicebasedonastackeddenoisingautoencoderindeeplearningandclusteringbyfastsearchwithoutdatalabels
AT xinli datadrivenbearingfaultdiagnosisofmicrogridnetworkpowerdevicebasedonastackeddenoisingautoencoderindeeplearningandclusteringbyfastsearchwithoutdatalabels
AT xiaodizhang datadrivenbearingfaultdiagnosisofmicrogridnetworkpowerdevicebasedonastackeddenoisingautoencoderindeeplearningandclusteringbyfastsearchwithoutdatalabels