Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait

Background. The complexity of the structure and function of a living body can be affected by disorders and can cause various dysfunctions. Objective. The aim of this study was to determine compensatory mechanisms in subjects with drop foot during gait. Methods. The study evaluated 10 subjects with d...

Full description

Saved in:
Bibliographic Details
Main Authors: Ida Wiszomirska, Michalina Błażkiewicz, Katarzyna Kaczmarczyk, Grażyna Brzuszkiewicz-Kuźmicka, Andrzej Wit
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:Applied Bionics and Biomechanics
Online Access:http://dx.doi.org/10.1155/2017/3595461
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832555514787004416
author Ida Wiszomirska
Michalina Błażkiewicz
Katarzyna Kaczmarczyk
Grażyna Brzuszkiewicz-Kuźmicka
Andrzej Wit
author_facet Ida Wiszomirska
Michalina Błażkiewicz
Katarzyna Kaczmarczyk
Grażyna Brzuszkiewicz-Kuźmicka
Andrzej Wit
author_sort Ida Wiszomirska
collection DOAJ
description Background. The complexity of the structure and function of a living body can be affected by disorders and can cause various dysfunctions. Objective. The aim of this study was to determine compensatory mechanisms in subjects with drop foot during gait. Methods. The study evaluated 10 subjects with drop foot (DF) whose results were compared to a group of 10 healthy controls (C). Spatiotemporal, kinematic, and kinetic parameters during the gait cycle were collected using Vicon system synchronized with Kistler platforms. Results. Spatiotemporal, kinematic, and kinetic parameters were significantly different between the analysed groups. In the DF group, the subjects walked almost 47% slower and performed 60% less steps per minute compared to the C group. The main problem in the DF group was insufficient ankle dorsiflexion in the 0–10% of the gait cycle. Mean values in the groups during the first 10% of the gait cycle were as follows: DF (−10.42 ± 5.7°) and C (−2.37 ± 1.47°), which affected the substantial differences in the values of muscle torque: DF (0.2 ± 0.1 Nm/kg) and C (−0.26 ± 0.06 Nm/kg). Conclusions. Comparative analysis for joint angles and torques demonstrated that the mechanism of compensation is the most noticeable in the knee joint and less in the hip joint.
format Article
id doaj-art-193d3c814d2b4ffdb3fc0935c883cb93
institution Kabale University
issn 1176-2322
1754-2103
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series Applied Bionics and Biomechanics
spelling doaj-art-193d3c814d2b4ffdb3fc0935c883cb932025-02-03T05:47:55ZengWileyApplied Bionics and Biomechanics1176-23221754-21032017-01-01201710.1155/2017/35954613595461Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during GaitIda Wiszomirska0Michalina Błażkiewicz1Katarzyna Kaczmarczyk2Grażyna Brzuszkiewicz-Kuźmicka3Andrzej Wit4Department of Physiotherapy, Józef Piłsudski University of Physical Education in Warsaw, 34 Marymoncka Str., Warsaw, PolandDepartment of Physiotherapy, Józef Piłsudski University of Physical Education in Warsaw, 34 Marymoncka Str., Warsaw, PolandDepartment of Physiotherapy, Józef Piłsudski University of Physical Education in Warsaw, 34 Marymoncka Str., Warsaw, PolandDepartment of Physiotherapy, Józef Piłsudski University of Physical Education in Warsaw, 34 Marymoncka Str., Warsaw, PolandDepartment of Physiotherapy, Józef Piłsudski University of Physical Education in Warsaw, 34 Marymoncka Str., Warsaw, PolandBackground. The complexity of the structure and function of a living body can be affected by disorders and can cause various dysfunctions. Objective. The aim of this study was to determine compensatory mechanisms in subjects with drop foot during gait. Methods. The study evaluated 10 subjects with drop foot (DF) whose results were compared to a group of 10 healthy controls (C). Spatiotemporal, kinematic, and kinetic parameters during the gait cycle were collected using Vicon system synchronized with Kistler platforms. Results. Spatiotemporal, kinematic, and kinetic parameters were significantly different between the analysed groups. In the DF group, the subjects walked almost 47% slower and performed 60% less steps per minute compared to the C group. The main problem in the DF group was insufficient ankle dorsiflexion in the 0–10% of the gait cycle. Mean values in the groups during the first 10% of the gait cycle were as follows: DF (−10.42 ± 5.7°) and C (−2.37 ± 1.47°), which affected the substantial differences in the values of muscle torque: DF (0.2 ± 0.1 Nm/kg) and C (−0.26 ± 0.06 Nm/kg). Conclusions. Comparative analysis for joint angles and torques demonstrated that the mechanism of compensation is the most noticeable in the knee joint and less in the hip joint.http://dx.doi.org/10.1155/2017/3595461
spellingShingle Ida Wiszomirska
Michalina Błażkiewicz
Katarzyna Kaczmarczyk
Grażyna Brzuszkiewicz-Kuźmicka
Andrzej Wit
Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
Applied Bionics and Biomechanics
title Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
title_full Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
title_fullStr Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
title_full_unstemmed Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
title_short Effect of Drop Foot on Spatiotemporal, Kinematic, and Kinetic Parameters during Gait
title_sort effect of drop foot on spatiotemporal kinematic and kinetic parameters during gait
url http://dx.doi.org/10.1155/2017/3595461
work_keys_str_mv AT idawiszomirska effectofdropfootonspatiotemporalkinematicandkineticparametersduringgait
AT michalinabłazkiewicz effectofdropfootonspatiotemporalkinematicandkineticparametersduringgait
AT katarzynakaczmarczyk effectofdropfootonspatiotemporalkinematicandkineticparametersduringgait
AT grazynabrzuszkiewiczkuzmicka effectofdropfootonspatiotemporalkinematicandkineticparametersduringgait
AT andrzejwit effectofdropfootonspatiotemporalkinematicandkineticparametersduringgait