Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography
Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images. Methods. Two independent, masked observers (SR and AZC) ident...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2012-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2012/487309 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832545694734352384 |
---|---|
author | Ricardo J. Cumba Sunita Radhakrishnan Nicholas P. Bell Kundandeep S. Nagi Alice Z. Chuang Shan C. Lin Kimberly A. Mankiewicz Robert M. Feldman |
author_facet | Ricardo J. Cumba Sunita Radhakrishnan Nicholas P. Bell Kundandeep S. Nagi Alice Z. Chuang Shan C. Lin Kimberly A. Mankiewicz Robert M. Feldman |
author_sort | Ricardo J. Cumba |
collection | DOAJ |
description | Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images. Methods. Two independent, masked observers (SR and AZC) identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750), and angle opening distance (AOD750) were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication) were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750. |
format | Article |
id | doaj-art-172123c808f04dfda4b97261efe17eac |
institution | Kabale University |
issn | 2090-004X 2090-0058 |
language | English |
publishDate | 2012-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Ophthalmology |
spelling | doaj-art-172123c808f04dfda4b97261efe17eac2025-02-03T07:24:52ZengWileyJournal of Ophthalmology2090-004X2090-00582012-01-01201210.1155/2012/487309487309Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence TomographyRicardo J. Cumba0Sunita Radhakrishnan1Nicholas P. Bell2Kundandeep S. Nagi3Alice Z. Chuang4Shan C. Lin5Kimberly A. Mankiewicz6Robert M. Feldman7Ruiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USAGlaucoma Center of San Francisco, 55 Stevenson Street, San Francisco, CA 94105, USARuiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USARuiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USARuiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USADepartment of Ophthalmology, University of California, San Francisco, 10 Koret Way, Room K-300, P.O. Box 0730, San Francisco, CA 94143, USARuiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USARuiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USAPurpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images. Methods. Two independent, masked observers (SR and AZC) identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750), and angle opening distance (AOD750) were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication) were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.http://dx.doi.org/10.1155/2012/487309 |
spellingShingle | Ricardo J. Cumba Sunita Radhakrishnan Nicholas P. Bell Kundandeep S. Nagi Alice Z. Chuang Shan C. Lin Kimberly A. Mankiewicz Robert M. Feldman Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography Journal of Ophthalmology |
title | Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography |
title_full | Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography |
title_fullStr | Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography |
title_full_unstemmed | Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography |
title_short | Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography |
title_sort | reproducibility of scleral spur identification and angle measurements using fourier domain anterior segment optical coherence tomography |
url | http://dx.doi.org/10.1155/2012/487309 |
work_keys_str_mv | AT ricardojcumba reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT sunitaradhakrishnan reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT nicholaspbell reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT kundandeepsnagi reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT alicezchuang reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT shanclin reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT kimberlyamankiewicz reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography AT robertmfeldman reproducibilityofscleralspuridentificationandanglemeasurementsusingfourierdomainanteriorsegmentopticalcoherencetomography |