Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff

Formaldehyde is widely used for the preservation of cadavers, exposing workers to potential risks of formaldehyde exposure in the workplace. This study compared the performance of real-time instruments (Gasmet) and absorbent tube methods in controlling formaldehyde levels in gross anatomy dissection...

Full description

Saved in:
Bibliographic Details
Main Authors: Phanpina Soonklang, Arroon Ketsakorn, Nontiya Homkham, Chalermchai Chaikittiporn, Saowanee Norkaew
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Toxicology Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214750025000319
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832590934574891008
author Phanpina Soonklang
Arroon Ketsakorn
Nontiya Homkham
Chalermchai Chaikittiporn
Saowanee Norkaew
author_facet Phanpina Soonklang
Arroon Ketsakorn
Nontiya Homkham
Chalermchai Chaikittiporn
Saowanee Norkaew
author_sort Phanpina Soonklang
collection DOAJ
description Formaldehyde is widely used for the preservation of cadavers, exposing workers to potential risks of formaldehyde exposure in the workplace. This study compared the performance of real-time instruments (Gasmet) and absorbent tube methods in controlling formaldehyde levels in gross anatomy dissections with four working process areas. The concentrations of formaldehyde were determined over working periods ranging from 2 to 5 h. For the Gasmet results, a Monte Carlo simulation was applied in the uncertainty analysis to predict the formaldehyde concentration. Data collection involved questionnaires that included personal and work-related information. The Wilcoxon matched-pairs signed-rank test and intraclass correlation coefficients (ICC) were used to test–retest reliability between the two instruments. The results showed that the Gasmet direct reading and absorbent tube concentrations were not significantly different (p > 0.05) in all working areas and ICC was 0.939 indicating a highly reliable test result between the two measurements. The health-risk estimation indicated the hazard quotient and carcinogenic risk of formaldehyde. The carcinogenic risk was found to be unacceptable for all staff and processes, while the hazard quotient was found to be acceptable only in the body injection process. Future studies should employ a larger sample size and a greater number of sampling points to enhance the statistical power and precision of the results. The findings of this study can be used to improve work environments and develop strategies to reduce the risks for staff who work in gross anatomy dissections.
format Article
id doaj-art-145366bae8a64d529160aa6db10baf47
institution Kabale University
issn 2214-7500
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Toxicology Reports
spelling doaj-art-145366bae8a64d529160aa6db10baf472025-01-23T05:26:45ZengElsevierToxicology Reports2214-75002025-06-0114101913Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staffPhanpina Soonklang0Arroon Ketsakorn1Nontiya Homkham2Chalermchai Chaikittiporn3Saowanee Norkaew4Faculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, ThailandFaculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, ThailandFaculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, ThailandFaculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, ThailandFaculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, Thailand; Thammasat University Research Unit in Occupational Ergonomics, Klong Nueng, Klong Luang, Pathum Thani 12121, Thailand; Corresponding author at: Faculty of Public Health, Thammasat University, Rangsit Campus, Klong Nueng, Klong Luang, Pathum Thani 12121, Thailand.Formaldehyde is widely used for the preservation of cadavers, exposing workers to potential risks of formaldehyde exposure in the workplace. This study compared the performance of real-time instruments (Gasmet) and absorbent tube methods in controlling formaldehyde levels in gross anatomy dissections with four working process areas. The concentrations of formaldehyde were determined over working periods ranging from 2 to 5 h. For the Gasmet results, a Monte Carlo simulation was applied in the uncertainty analysis to predict the formaldehyde concentration. Data collection involved questionnaires that included personal and work-related information. The Wilcoxon matched-pairs signed-rank test and intraclass correlation coefficients (ICC) were used to test–retest reliability between the two instruments. The results showed that the Gasmet direct reading and absorbent tube concentrations were not significantly different (p > 0.05) in all working areas and ICC was 0.939 indicating a highly reliable test result between the two measurements. The health-risk estimation indicated the hazard quotient and carcinogenic risk of formaldehyde. The carcinogenic risk was found to be unacceptable for all staff and processes, while the hazard quotient was found to be acceptable only in the body injection process. Future studies should employ a larger sample size and a greater number of sampling points to enhance the statistical power and precision of the results. The findings of this study can be used to improve work environments and develop strategies to reduce the risks for staff who work in gross anatomy dissections.http://www.sciencedirect.com/science/article/pii/S2214750025000319Air monitoringDirect readingFormaldehyde monitoringMonte carloOccupational exposureOccupational safety
spellingShingle Phanpina Soonklang
Arroon Ketsakorn
Nontiya Homkham
Chalermchai Chaikittiporn
Saowanee Norkaew
Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
Toxicology Reports
Air monitoring
Direct reading
Formaldehyde monitoring
Monte carlo
Occupational exposure
Occupational safety
title Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
title_full Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
title_fullStr Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
title_full_unstemmed Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
title_short Comparison of real-time instrument use and absorbent tube method for measuring formaldehyde in working environments: A health risk assessment for gross anatomy staff
title_sort comparison of real time instrument use and absorbent tube method for measuring formaldehyde in working environments a health risk assessment for gross anatomy staff
topic Air monitoring
Direct reading
Formaldehyde monitoring
Monte carlo
Occupational exposure
Occupational safety
url http://www.sciencedirect.com/science/article/pii/S2214750025000319
work_keys_str_mv AT phanpinasoonklang comparisonofrealtimeinstrumentuseandabsorbenttubemethodformeasuringformaldehydeinworkingenvironmentsahealthriskassessmentforgrossanatomystaff
AT arroonketsakorn comparisonofrealtimeinstrumentuseandabsorbenttubemethodformeasuringformaldehydeinworkingenvironmentsahealthriskassessmentforgrossanatomystaff
AT nontiyahomkham comparisonofrealtimeinstrumentuseandabsorbenttubemethodformeasuringformaldehydeinworkingenvironmentsahealthriskassessmentforgrossanatomystaff
AT chalermchaichaikittiporn comparisonofrealtimeinstrumentuseandabsorbenttubemethodformeasuringformaldehydeinworkingenvironmentsahealthriskassessmentforgrossanatomystaff
AT saowaneenorkaew comparisonofrealtimeinstrumentuseandabsorbenttubemethodformeasuringformaldehydeinworkingenvironmentsahealthriskassessmentforgrossanatomystaff