An easy approach to ultrasonographic volumetry of the thyroid
To establish an easy way to perform volumetry of the thyroid gland using ultrasonography, we evaluated the accuracy of the products of the depth and width of the right thyroid lobe as indices of thyroid volume. The depth and width of both thyroid lobes were measured using ultrasonography before surg...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Japan Endocrine Society
2024-06-01
|
Series: | Endocrine Journal |
Subjects: | |
Online Access: | https://www.jstage.jst.go.jp/article/endocrj/71/6/71_EJ23-0606/_html/-char/en |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832591892266614784 |
---|---|
author | Tsukasa Murakami Naoyuki Higaki Yui Nishijima Junichi Tani Hitoshi Noguchi Manami Morisaki Misako Eto Yoshiko Tani |
author_facet | Tsukasa Murakami Naoyuki Higaki Yui Nishijima Junichi Tani Hitoshi Noguchi Manami Morisaki Misako Eto Yoshiko Tani |
author_sort | Tsukasa Murakami |
collection | DOAJ |
description | To establish an easy way to perform volumetry of the thyroid gland using ultrasonography, we evaluated the accuracy of the products of the depth and width of the right thyroid lobe as indices of thyroid volume. The depth and width of both thyroid lobes were measured using ultrasonography before surgery in 193 patients with Graves’ disease. The products were compared with the weight of the thyroid obtained from operative records. We also evaluated the depth and width of the right thyroid lobe in 312 subjects who presented without any thyroid disease. The products of depth and width of the right and left lobes of patients with Graves’ disease correlated similarly well with the weight of the thyroid obtained from operative records (ρ = 0.896 for right, ρ = 0.886 for left, p < 0.0001). Because the right lobes were larger than the left lobes, the products of the depth and width of the right lobe were adopted as novel parameters for an easy volumetric approach. The relationship between the weight and the measurements of the right lobe was described using the following regression equation: weight (g) = [11.8 × depth (cm) × width (cm)] – 16.0. The products of the subjects without any thyroid diseases were distributed between 0.6 cm2 and 4.4 cm2, with a median of 2.0 cm2. The upper limit of these values in these subjects was estimated to be 3.8 cm2. This easy ultrasonographic volumetric technique makes it possible to perform a semi-quantitative assessment of thyroid volume and to differentiate diffuse goiter from normal-sized thyroids. |
format | Article |
id | doaj-art-14319c17eec54601a70c3572229d2fb7 |
institution | Kabale University |
issn | 1348-4540 |
language | English |
publishDate | 2024-06-01 |
publisher | The Japan Endocrine Society |
record_format | Article |
series | Endocrine Journal |
spelling | doaj-art-14319c17eec54601a70c3572229d2fb72025-01-22T05:07:43ZengThe Japan Endocrine SocietyEndocrine Journal1348-45402024-06-0171661762110.1507/endocrj.EJ23-0606endocrjAn easy approach to ultrasonographic volumetry of the thyroidTsukasa Murakami0Naoyuki Higaki1Yui Nishijima2Junichi Tani3Hitoshi Noguchi4Manami Morisaki5Misako Eto6Yoshiko Tani7Department of Endocrinology, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Endocrinology, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Endocrinology, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Endocrinology, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Endocrinology, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Laboratory Medicine, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Laboratory Medicine, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanDepartment of Laboratory Medicine, Noguchi Thyroid Clinic and Hospital Foundation, Oita 874-0902 JapanTo establish an easy way to perform volumetry of the thyroid gland using ultrasonography, we evaluated the accuracy of the products of the depth and width of the right thyroid lobe as indices of thyroid volume. The depth and width of both thyroid lobes were measured using ultrasonography before surgery in 193 patients with Graves’ disease. The products were compared with the weight of the thyroid obtained from operative records. We also evaluated the depth and width of the right thyroid lobe in 312 subjects who presented without any thyroid disease. The products of depth and width of the right and left lobes of patients with Graves’ disease correlated similarly well with the weight of the thyroid obtained from operative records (ρ = 0.896 for right, ρ = 0.886 for left, p < 0.0001). Because the right lobes were larger than the left lobes, the products of the depth and width of the right lobe were adopted as novel parameters for an easy volumetric approach. The relationship between the weight and the measurements of the right lobe was described using the following regression equation: weight (g) = [11.8 × depth (cm) × width (cm)] – 16.0. The products of the subjects without any thyroid diseases were distributed between 0.6 cm2 and 4.4 cm2, with a median of 2.0 cm2. The upper limit of these values in these subjects was estimated to be 3.8 cm2. This easy ultrasonographic volumetric technique makes it possible to perform a semi-quantitative assessment of thyroid volume and to differentiate diffuse goiter from normal-sized thyroids.https://www.jstage.jst.go.jp/article/endocrj/71/6/71_EJ23-0606/_html/-char/engraves’ diseasediffuse goiterultrasonographyvolumetry |
spellingShingle | Tsukasa Murakami Naoyuki Higaki Yui Nishijima Junichi Tani Hitoshi Noguchi Manami Morisaki Misako Eto Yoshiko Tani An easy approach to ultrasonographic volumetry of the thyroid Endocrine Journal graves’ disease diffuse goiter ultrasonography volumetry |
title | An easy approach to ultrasonographic volumetry of the thyroid |
title_full | An easy approach to ultrasonographic volumetry of the thyroid |
title_fullStr | An easy approach to ultrasonographic volumetry of the thyroid |
title_full_unstemmed | An easy approach to ultrasonographic volumetry of the thyroid |
title_short | An easy approach to ultrasonographic volumetry of the thyroid |
title_sort | easy approach to ultrasonographic volumetry of the thyroid |
topic | graves’ disease diffuse goiter ultrasonography volumetry |
url | https://www.jstage.jst.go.jp/article/endocrj/71/6/71_EJ23-0606/_html/-char/en |
work_keys_str_mv | AT tsukasamurakami aneasyapproachtoultrasonographicvolumetryofthethyroid AT naoyukihigaki aneasyapproachtoultrasonographicvolumetryofthethyroid AT yuinishijima aneasyapproachtoultrasonographicvolumetryofthethyroid AT junichitani aneasyapproachtoultrasonographicvolumetryofthethyroid AT hitoshinoguchi aneasyapproachtoultrasonographicvolumetryofthethyroid AT manamimorisaki aneasyapproachtoultrasonographicvolumetryofthethyroid AT misakoeto aneasyapproachtoultrasonographicvolumetryofthethyroid AT yoshikotani aneasyapproachtoultrasonographicvolumetryofthethyroid AT tsukasamurakami easyapproachtoultrasonographicvolumetryofthethyroid AT naoyukihigaki easyapproachtoultrasonographicvolumetryofthethyroid AT yuinishijima easyapproachtoultrasonographicvolumetryofthethyroid AT junichitani easyapproachtoultrasonographicvolumetryofthethyroid AT hitoshinoguchi easyapproachtoultrasonographicvolumetryofthethyroid AT manamimorisaki easyapproachtoultrasonographicvolumetryofthethyroid AT misakoeto easyapproachtoultrasonographicvolumetryofthethyroid AT yoshikotani easyapproachtoultrasonographicvolumetryofthethyroid |