Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization

Fluoroscopy is a type of medical imaging that shows a continuous X-ray image on a screen, it is used in a wide range of examination and procedures for diagnosis such as in cardiac catheterization. Fluoroscopy can result in relatively high radiation doses, especially for complex interventional proce...

Full description

Saved in:
Bibliographic Details
Main Authors: Luma Naji, Susan Zwyea, Alyaa Raheem
Format: Article
Language:English
Published: middle technical university 2020-03-01
Series:Journal of Techniques
Subjects:
Online Access:https://journal.mtu.edu.iq/index.php/MTU/article/view/165
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832595024237297664
author Luma Naji
Susan Zwyea
Alyaa Raheem
author_facet Luma Naji
Susan Zwyea
Alyaa Raheem
author_sort Luma Naji
collection DOAJ
description Fluoroscopy is a type of medical imaging that shows a continuous X-ray image on a screen, it is used in a wide range of examination and procedures for diagnosis such as in cardiac catheterization. Fluoroscopy can result in relatively high radiation doses, especially for complex interventional procedures that it needed to monitor radiation to reduce exposure. The purpose of this study is to determine the radiation doses for patients during cardiac catheterization exam and compare it with the permissible dose limits. The main parameters which are studied in this work are the time of exposure dose rate, x-ray techniques (milliamper. second), tube voltage (kilovolt) and Dose Area Product (DAP). Twenty-seven patients were included and  absorbed doses were measured and distributed according to Fluoroscopy (Fluo) time, mAs and Dose Area Product (DPA). It was found that the absorbed dose received by the patients has a  linear relationship with the Fluoroscopy time, mAs and DAP. Exposure dose rates were measured and compared with the maximum permissible dose (100 mGy/min), the estimated patient dose rate varied from (12-81.6) mGy/min) for 24 patients as a permissible dose in the safe side, and 3 patients exposed to higher values of the exposure dose rates ) over permissible dose) range (107.4-108) mGy/min
format Article
id doaj-art-13d6cafdd60640b9a998b20aedc6b0a8
institution Kabale University
issn 1818-653X
2708-8383
language English
publishDate 2020-03-01
publisher middle technical university
record_format Article
series Journal of Techniques
spelling doaj-art-13d6cafdd60640b9a998b20aedc6b0a82025-01-19T11:09:10Zengmiddle technical universityJournal of Techniques1818-653X2708-83832020-03-012110.51173/jt.v2i1.165Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterizationLuma Naji0Susan Zwyea1Alyaa Raheem2College of Health & Medical Technology - Baghdad, Middle Technical University, Baghdad, IraqCollege of Health & Medical Technology - Baghdad, Middle Technical University, Baghdad, IraqCollege of Health & Medical Technology - Baghdad, Middle Technical University, Baghdad, Iraq Fluoroscopy is a type of medical imaging that shows a continuous X-ray image on a screen, it is used in a wide range of examination and procedures for diagnosis such as in cardiac catheterization. Fluoroscopy can result in relatively high radiation doses, especially for complex interventional procedures that it needed to monitor radiation to reduce exposure. The purpose of this study is to determine the radiation doses for patients during cardiac catheterization exam and compare it with the permissible dose limits. The main parameters which are studied in this work are the time of exposure dose rate, x-ray techniques (milliamper. second), tube voltage (kilovolt) and Dose Area Product (DAP). Twenty-seven patients were included and  absorbed doses were measured and distributed according to Fluoroscopy (Fluo) time, mAs and Dose Area Product (DPA). It was found that the absorbed dose received by the patients has a  linear relationship with the Fluoroscopy time, mAs and DAP. Exposure dose rates were measured and compared with the maximum permissible dose (100 mGy/min), the estimated patient dose rate varied from (12-81.6) mGy/min) for 24 patients as a permissible dose in the safe side, and 3 patients exposed to higher values of the exposure dose rates ) over permissible dose) range (107.4-108) mGy/min https://journal.mtu.edu.iq/index.php/MTU/article/view/165FluoroscopyCardiac CatheterizationExposure DoseEstimated Patient Dose
spellingShingle Luma Naji
Susan Zwyea
Alyaa Raheem
Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
Journal of Techniques
Fluoroscopy
Cardiac Catheterization
Exposure Dose
Estimated Patient Dose
title Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
title_full Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
title_fullStr Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
title_full_unstemmed Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
title_short Measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
title_sort measurement of the radiation level dose to patient from fluoroscopy device during cardiac catheterization
topic Fluoroscopy
Cardiac Catheterization
Exposure Dose
Estimated Patient Dose
url https://journal.mtu.edu.iq/index.php/MTU/article/view/165
work_keys_str_mv AT lumanaji measurementoftheradiationleveldosetopatientfromfluoroscopydeviceduringcardiaccatheterization
AT susanzwyea measurementoftheradiationleveldosetopatientfromfluoroscopydeviceduringcardiaccatheterization
AT alyaaraheem measurementoftheradiationleveldosetopatientfromfluoroscopydeviceduringcardiaccatheterization