HIGH-FREQUENCY MICROINDUCTOR ON THE BASE OF FLEXIBLE POLYIMIDE FILM

A method of creation of 3D flexible high-frequency microinductor on the base of polyimide film with etched swift heavy ion tracks, filled with a conducting material is proposed. This methos is more simple as compared with existing technologies. The service model of the microinductor having dimension...

Full description

Saved in:
Bibliographic Details
Main Authors: A. V. Petrov, S. E. Demyanov, E. Yu. Kaniukov, D. Fink
Format: Article
Language:English
Published: Belarusian National Technical University 2015-04-01
Series:Приборы и методы измерений
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/135
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A method of creation of 3D flexible high-frequency microinductor on the base of polyimide film with etched swift heavy ion tracks, filled with a conducting material is proposed. This methos is more simple as compared with existing technologies. The service model of the microinductor having dimensions 0,04 mm3 is fabricated. This model has following main operational characteristics: winding density of 7 winding/mm at the winding thickness 10 μm; inductivity 0.3 mH with the Q-factor of 8 at 200 MHz. A possibility of the decrease of dimensions of the device down to 10-6 mm3 is shown.
ISSN:2220-9506
2414-0473