Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets

Purpose. To compare the efficacy of passive drainage (PD) and repeated fluid-air (FA) exchange for removing emulsified silicone oil (SO) droplets. Methods. Twenty rhegmatogenous retinal detachment (RRD) patients who underwent primary pars plana vitrectomy (PPV) with SO tamponade were randomly and ev...

Full description

Saved in:
Bibliographic Details
Main Authors: Jian Yu, Yuan Zong, Ye Tan, Chunhui Jiang, Gezhi Xu
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2020/8184607
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566045390405632
author Jian Yu
Yuan Zong
Ye Tan
Chunhui Jiang
Gezhi Xu
author_facet Jian Yu
Yuan Zong
Ye Tan
Chunhui Jiang
Gezhi Xu
author_sort Jian Yu
collection DOAJ
description Purpose. To compare the efficacy of passive drainage (PD) and repeated fluid-air (FA) exchange for removing emulsified silicone oil (SO) droplets. Methods. Twenty rhegmatogenous retinal detachment (RRD) patients who underwent primary pars plana vitrectomy (PPV) with SO tamponade were randomly and evenly divided into two groups for PD and FA exchange. Once the bulk of SO was removed, the first 2 mL of the washout fluid was collected, and then, another 2 mL of the washout fluid was collected after PD or FA exchange. The size and number of SO droplets in the washout fluid were measured using a Coulter counter (Multisizer 3, Beckman Coulter, Indianapolis, IN, USA). The efficiencies of FA exchange and PD for removing emulsified SO were compared. Results. The number of SO droplets decreased significantly after FA exchange and PD. The decrease in the number of droplets was statistically significant for larger droplets (>4 µm) with PD and for all droplet sizes with FA exchange. The decrease in the number of SO droplets of <4 μm was significantly greater with FA exchange than with PD. However, at the end of the procedure, the overall number and size distribution of SO droplets were similar for both procedures. Conclusions. PD and FA exchange reduced the number of residual emulsified SO droplets after SO tamponade efficiently. FA exchange may have some advantages over PD in removing small droplets.
format Article
id doaj-art-132e75ef25e5471e9a0fd4ab2fa7769c
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-132e75ef25e5471e9a0fd4ab2fa7769c2025-02-03T01:05:08ZengWileyJournal of Ophthalmology2090-004X2090-00582020-01-01202010.1155/2020/81846078184607Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil DropletsJian Yu0Yuan Zong1Ye Tan2Chunhui Jiang3Gezhi Xu4Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, ChinaGongli Hospital of Shanghai Pudong New Area, Shanghai 200135, ChinaDepartment of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, ChinaDepartment of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, ChinaPurpose. To compare the efficacy of passive drainage (PD) and repeated fluid-air (FA) exchange for removing emulsified silicone oil (SO) droplets. Methods. Twenty rhegmatogenous retinal detachment (RRD) patients who underwent primary pars plana vitrectomy (PPV) with SO tamponade were randomly and evenly divided into two groups for PD and FA exchange. Once the bulk of SO was removed, the first 2 mL of the washout fluid was collected, and then, another 2 mL of the washout fluid was collected after PD or FA exchange. The size and number of SO droplets in the washout fluid were measured using a Coulter counter (Multisizer 3, Beckman Coulter, Indianapolis, IN, USA). The efficiencies of FA exchange and PD for removing emulsified SO were compared. Results. The number of SO droplets decreased significantly after FA exchange and PD. The decrease in the number of droplets was statistically significant for larger droplets (>4 µm) with PD and for all droplet sizes with FA exchange. The decrease in the number of SO droplets of <4 μm was significantly greater with FA exchange than with PD. However, at the end of the procedure, the overall number and size distribution of SO droplets were similar for both procedures. Conclusions. PD and FA exchange reduced the number of residual emulsified SO droplets after SO tamponade efficiently. FA exchange may have some advantages over PD in removing small droplets.http://dx.doi.org/10.1155/2020/8184607
spellingShingle Jian Yu
Yuan Zong
Ye Tan
Chunhui Jiang
Gezhi Xu
Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
Journal of Ophthalmology
title Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
title_full Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
title_fullStr Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
title_full_unstemmed Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
title_short Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets
title_sort comparison of repeated fluid air exchange and passive drainage for removing residual emulsified silicone oil droplets
url http://dx.doi.org/10.1155/2020/8184607
work_keys_str_mv AT jianyu comparisonofrepeatedfluidairexchangeandpassivedrainageforremovingresidualemulsifiedsiliconeoildroplets
AT yuanzong comparisonofrepeatedfluidairexchangeandpassivedrainageforremovingresidualemulsifiedsiliconeoildroplets
AT yetan comparisonofrepeatedfluidairexchangeandpassivedrainageforremovingresidualemulsifiedsiliconeoildroplets
AT chunhuijiang comparisonofrepeatedfluidairexchangeandpassivedrainageforremovingresidualemulsifiedsiliconeoildroplets
AT gezhixu comparisonofrepeatedfluidairexchangeandpassivedrainageforremovingresidualemulsifiedsiliconeoildroplets