Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values

Background: One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone den...

Full description

Saved in:
Bibliographic Details
Main Authors: Rashmit Kumar, Kurian Punnoose, Meenakumari Chikkanna, Srikanth Gunturu, Mosa Mohammad Alrifai, Abdulghani Saeed Al Zahrani, J. Suresh Babu, C. Swarnalatha, Abhishek Singh Nayyar
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2025-01-01
Series:Advanced Biomedical Research
Subjects:
Online Access:https://journals.lww.com/10.4103/abr.abr_313_24
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832086802853265408
author Rashmit Kumar
Kurian Punnoose
Meenakumari Chikkanna
Srikanth Gunturu
Mosa Mohammad Alrifai
Abdulghani Saeed Al Zahrani
J. Suresh Babu
C. Swarnalatha
Abhishek Singh Nayyar
author_facet Rashmit Kumar
Kurian Punnoose
Meenakumari Chikkanna
Srikanth Gunturu
Mosa Mohammad Alrifai
Abdulghani Saeed Al Zahrani
J. Suresh Babu
C. Swarnalatha
Abhishek Singh Nayyar
author_sort Rashmit Kumar
collection DOAJ
description Background: One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two. Materials and Methods: The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson’s correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant. Results: Pearson’s correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance. Conclusions: The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.
format Article
id doaj-art-12dce4e9ff8740f2bbe810f919a5532c
institution Kabale University
issn 2277-9175
language English
publishDate 2025-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Advanced Biomedical Research
spelling doaj-art-12dce4e9ff8740f2bbe810f919a5532c2025-02-06T09:41:42ZengWolters Kluwer Medknow PublicationsAdvanced Biomedical Research2277-91752025-01-011418810.4103/abr.abr_313_24Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual ValuesRashmit KumarKurian PunnooseMeenakumari ChikkannaSrikanth GunturuMosa Mohammad AlrifaiAbdulghani Saeed Al ZahraniJ. Suresh BabuC. SwarnalathaAbhishek Singh NayyarBackground: One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two. Materials and Methods: The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson’s correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant. Results: Pearson’s correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance. Conclusions: The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.https://journals.lww.com/10.4103/abr.abr_313_24bone densitycomputed tomography (ct)cone beam computed tomography (cone beam ct)in-vitro study
spellingShingle Rashmit Kumar
Kurian Punnoose
Meenakumari Chikkanna
Srikanth Gunturu
Mosa Mohammad Alrifai
Abdulghani Saeed Al Zahrani
J. Suresh Babu
C. Swarnalatha
Abhishek Singh Nayyar
Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
Advanced Biomedical Research
bone density
computed tomography (ct)
cone beam computed tomography (cone beam ct)
in-vitro study
title Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
title_full Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
title_fullStr Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
title_full_unstemmed Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
title_short Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values
title_sort bone densitometric analysis using cone beam computed tomography cone beam ct and computed tomography ct establishing the correlation between predicted and actual values
topic bone density
computed tomography (ct)
cone beam computed tomography (cone beam ct)
in-vitro study
url https://journals.lww.com/10.4103/abr.abr_313_24
work_keys_str_mv AT rashmitkumar bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT kurianpunnoose bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT meenakumarichikkanna bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT srikanthgunturu bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT mosamohammadalrifai bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT abdulghanisaeedalzahrani bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT jsureshbabu bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT cswarnalatha bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues
AT abhisheksinghnayyar bonedensitometricanalysisusingconebeamcomputedtomographyconebeamctandcomputedtomographyctestablishingthecorrelationbetweenpredictedandactualvalues