Optimization Criteria of Power Transformer Operation
It has been shown that minimum losses in active power of a power transformer do not correspond to its maximum efficiency. For a transformer being operated there are no so called «zones of its economical operation». In this case strictly specified value of active power losses corresponds to a particu...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2006-02-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/729 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543685865111552 |
---|---|
author | A. A. Gonchar |
author_facet | A. A. Gonchar |
author_sort | A. A. Gonchar |
collection | DOAJ |
description | It has been shown that minimum losses in active power of a power transformer do not correspond to its maximum efficiency. For a transformer being operated there are no so called «zones of its economical operation». In this case strictly specified value of active power losses corresponds to a particular current of the winding. |
format | Article |
id | doaj-art-12b06a78edcb428d936f02246c54656a |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2006-02-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-12b06a78edcb428d936f02246c54656a2025-02-03T11:34:21ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412006-02-01012630722Optimization Criteria of Power Transformer OperationA. A. GoncharIt has been shown that minimum losses in active power of a power transformer do not correspond to its maximum efficiency. For a transformer being operated there are no so called «zones of its economical operation». In this case strictly specified value of active power losses corresponds to a particular current of the winding.https://energy.bntu.by/jour/article/view/729 |
spellingShingle | A. A. Gonchar Optimization Criteria of Power Transformer Operation Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | Optimization Criteria of Power Transformer Operation |
title_full | Optimization Criteria of Power Transformer Operation |
title_fullStr | Optimization Criteria of Power Transformer Operation |
title_full_unstemmed | Optimization Criteria of Power Transformer Operation |
title_short | Optimization Criteria of Power Transformer Operation |
title_sort | optimization criteria of power transformer operation |
url | https://energy.bntu.by/jour/article/view/729 |
work_keys_str_mv | AT aagonchar optimizationcriteriaofpowertransformeroperation |