Entanglement due to Delayed Removal of a Buddy Wire
A buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels. We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second stent and subsequent distortion of the stent within the guidin...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | Case Reports in Cardiology |
Online Access: | http://dx.doi.org/10.1155/2014/513737 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832558500159422464 |
---|---|
author | Marc Vorpahl Melchior Seyfarth Klaus Tiroch |
author_facet | Marc Vorpahl Melchior Seyfarth Klaus Tiroch |
author_sort | Marc Vorpahl |
collection | DOAJ |
description | A buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels. We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second stent and subsequent distortion of the stent within the guiding catheter. Based on this case, we suggest removing the buddy wire immediately after successful positioning of the first stent, because entrapment with a second stent is possible and may lead to challenging situations in a simultaneous two-stent strategy. |
format | Article |
id | doaj-art-114320ff70944cca986049c167a66269 |
institution | Kabale University |
issn | 2090-6404 2090-6412 |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Cardiology |
spelling | doaj-art-114320ff70944cca986049c167a662692025-02-03T01:32:11ZengWileyCase Reports in Cardiology2090-64042090-64122014-01-01201410.1155/2014/513737513737Entanglement due to Delayed Removal of a Buddy WireMarc Vorpahl0Melchior Seyfarth1Klaus Tiroch2Department of Cardiology, HELIOS Klinikum Wuppertal, Witten/Herdecke University, Arrenberger Strasse 20, 42117 Wuppertal, GermanyDepartment of Cardiology, HELIOS Klinikum Wuppertal, Witten/Herdecke University, Arrenberger Strasse 20, 42117 Wuppertal, GermanyDepartment of Cardiology, HELIOS Klinikum Wuppertal, Witten/Herdecke University, Arrenberger Strasse 20, 42117 Wuppertal, GermanyA buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels. We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second stent and subsequent distortion of the stent within the guiding catheter. Based on this case, we suggest removing the buddy wire immediately after successful positioning of the first stent, because entrapment with a second stent is possible and may lead to challenging situations in a simultaneous two-stent strategy.http://dx.doi.org/10.1155/2014/513737 |
spellingShingle | Marc Vorpahl Melchior Seyfarth Klaus Tiroch Entanglement due to Delayed Removal of a Buddy Wire Case Reports in Cardiology |
title | Entanglement due to Delayed Removal of a Buddy Wire |
title_full | Entanglement due to Delayed Removal of a Buddy Wire |
title_fullStr | Entanglement due to Delayed Removal of a Buddy Wire |
title_full_unstemmed | Entanglement due to Delayed Removal of a Buddy Wire |
title_short | Entanglement due to Delayed Removal of a Buddy Wire |
title_sort | entanglement due to delayed removal of a buddy wire |
url | http://dx.doi.org/10.1155/2014/513737 |
work_keys_str_mv | AT marcvorpahl entanglementduetodelayedremovalofabuddywire AT melchiorseyfarth entanglementduetodelayedremovalofabuddywire AT klaustiroch entanglementduetodelayedremovalofabuddywire |