Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process

Metals used in biomedical applications are frequently coated to prevent oxidation and metallic ion release, both of which can be harmful due to toxic effects. To prevent these adverse effects of metals, researchers have focused their efforts on developing various coating techniques, facilitating sur...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Prakash, C. S. Abdul Favas, I. Ameeth Basha, R. Venkatesh, M. Prabhahar, V. P. Durairaj, K. Gomathi, Haiter Lenin
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Advances in Materials Science and Engineering
Online Access:http://dx.doi.org/10.1155/2022/5133610
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832555165802037248
author S. Prakash
C. S. Abdul Favas
I. Ameeth Basha
R. Venkatesh
M. Prabhahar
V. P. Durairaj
K. Gomathi
Haiter Lenin
author_facet S. Prakash
C. S. Abdul Favas
I. Ameeth Basha
R. Venkatesh
M. Prabhahar
V. P. Durairaj
K. Gomathi
Haiter Lenin
author_sort S. Prakash
collection DOAJ
description Metals used in biomedical applications are frequently coated to prevent oxidation and metallic ion release, both of which can be harmful due to toxic effects. To prevent these adverse effects of metals, researchers have focused their efforts on developing various coating techniques, facilitating surface coating, or obtaining functional surfaces. (WEDM) is now considered a difficult method of obtaining functional surfaces for medical applications. The properties of the surface and subsurface layers obtained by the WEDM method are particularly interesting in this regard. The analysis utilised RSM-based computational technique to evaluate the WEDM characteristics (MRR SR) of Ti6Al4V Titanium Alloy in biomedical applications. The biggest drawback of the material in the biomedical industry, which includes orthopedic applications and dental implants, would be that it releases harmful atoms such as iron, chromium, and nickel into the bodily fluid environment. To combat the problems, a hydroxyapatite layer applied to the metal implant improves biocompatibility, osteocompatibility, and antimicrobial properties. By comparing the Modified Differential Evolution (MDE) approach to the basic differential evolution (DE) optimization strategy, the effectiveness of the MDE approach has been established. According to the cyclic polarized test, the Hap coated Titanium material had better corrosion resistance than the pure sample. The Hap coated titanium material has a higher zone of inhibition than the pure sample. The next step is to synthesis hydroxyapatite from cuttlebone, which is then electrodeposited onto titanium. FTIR, electrochemical tests, FESEM, and SEM were used to describe the coated sample, as well as an antibacterial test using E. Coli and B. Cereus bacteria. Because it is porous, the Hap coating helps bone tissue growth by preventing detrimental metal ions from escaping into the biological medium. The corrosion inhibition efficiency of the coated sample was performed in SBF (NaHCO3—0.35 g/L, MgCl2.6H2O—0.30 g/L, CaCl2·2H2O—0.37 g/L, K2HPO4. 3H2O—0.23 g/L, Na2SO4—0.071 g/L, NaCl—7.99 g/L, KCl—0.22 g/L, Tris’s buffer—6.063 g/L) solution using the potentiodynamic polarisation method and the solution pH was maintained.
format Article
id doaj-art-10a74fe624994a41861f2cadf2323854
institution Kabale University
issn 1687-8442
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Advances in Materials Science and Engineering
spelling doaj-art-10a74fe624994a41861f2cadf23238542025-02-03T05:49:20ZengWileyAdvances in Materials Science and Engineering1687-84422022-01-01202210.1155/2022/5133610Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM ProcessS. Prakash0C. S. Abdul Favas1I. Ameeth Basha2R. Venkatesh3M. Prabhahar4V. P. Durairaj5K. Gomathi6Haiter Lenin7Department of Mechanical EngineeringDepartment of Mechanical EngineeringDepartment of ChemistryDepartment of Mechanical EngineeringDepartment of Mechanical EngineeringDepartment of Mechanical EngineeringDept of BiotechnologyDepartment of Mechanical EngineeringMetals used in biomedical applications are frequently coated to prevent oxidation and metallic ion release, both of which can be harmful due to toxic effects. To prevent these adverse effects of metals, researchers have focused their efforts on developing various coating techniques, facilitating surface coating, or obtaining functional surfaces. (WEDM) is now considered a difficult method of obtaining functional surfaces for medical applications. The properties of the surface and subsurface layers obtained by the WEDM method are particularly interesting in this regard. The analysis utilised RSM-based computational technique to evaluate the WEDM characteristics (MRR SR) of Ti6Al4V Titanium Alloy in biomedical applications. The biggest drawback of the material in the biomedical industry, which includes orthopedic applications and dental implants, would be that it releases harmful atoms such as iron, chromium, and nickel into the bodily fluid environment. To combat the problems, a hydroxyapatite layer applied to the metal implant improves biocompatibility, osteocompatibility, and antimicrobial properties. By comparing the Modified Differential Evolution (MDE) approach to the basic differential evolution (DE) optimization strategy, the effectiveness of the MDE approach has been established. According to the cyclic polarized test, the Hap coated Titanium material had better corrosion resistance than the pure sample. The Hap coated titanium material has a higher zone of inhibition than the pure sample. The next step is to synthesis hydroxyapatite from cuttlebone, which is then electrodeposited onto titanium. FTIR, electrochemical tests, FESEM, and SEM were used to describe the coated sample, as well as an antibacterial test using E. Coli and B. Cereus bacteria. Because it is porous, the Hap coating helps bone tissue growth by preventing detrimental metal ions from escaping into the biological medium. The corrosion inhibition efficiency of the coated sample was performed in SBF (NaHCO3—0.35 g/L, MgCl2.6H2O—0.30 g/L, CaCl2·2H2O—0.37 g/L, K2HPO4. 3H2O—0.23 g/L, Na2SO4—0.071 g/L, NaCl—7.99 g/L, KCl—0.22 g/L, Tris’s buffer—6.063 g/L) solution using the potentiodynamic polarisation method and the solution pH was maintained.http://dx.doi.org/10.1155/2022/5133610
spellingShingle S. Prakash
C. S. Abdul Favas
I. Ameeth Basha
R. Venkatesh
M. Prabhahar
V. P. Durairaj
K. Gomathi
Haiter Lenin
Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
Advances in Materials Science and Engineering
title Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
title_full Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
title_fullStr Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
title_full_unstemmed Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
title_short Investigation of Mechanical and Tribological Characteristics of Medical Grade Ti6al4v Titanium Alloy in Addition with Corrosion Study for Wire EDM Process
title_sort investigation of mechanical and tribological characteristics of medical grade ti6al4v titanium alloy in addition with corrosion study for wire edm process
url http://dx.doi.org/10.1155/2022/5133610
work_keys_str_mv AT sprakash investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT csabdulfavas investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT iameethbasha investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT rvenkatesh investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT mprabhahar investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT vpdurairaj investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT kgomathi investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess
AT haiterlenin investigationofmechanicalandtribologicalcharacteristicsofmedicalgradeti6al4vtitaniumalloyinadditionwithcorrosionstudyforwireedmprocess